Thermal Cutoffs (Thermal Fuses and Breakers)

Thermal Cutoffs (Thermal Fuses and Breakers)

Circuit protection devices include products used to protect electrical circuits from damage caused by hazards such as static discharge (such as Transient Voltage Suppression diodes and gas discharge tubes) as well as products designed to reduce the risk of fire caused by electrical overload or circuit failure, such as fuses and circuit breakers. Related accessories designed for use with such products are also included, such as fuse holders, fuse pullers, and mounting bases for circuit breakers.

Operating Temperature

Package / Case

-

Axial

Nonstandard SMD

Radial

Nonstandard

Cylinder

Radial, Box

2-SMD, No Lead

Strap

Cylinder, Wire Leads

Manufacturer

Eaton

Bourns, Inc.

Cantherm

OptiFuse

SCHURTER

Panasonic

TDK-Lambda, Inc.

Hamlin / Littelfuse

SETsafe | SETfuse

Master Appliance Corp.

Angstrohm / Vishay

US Electronics Inc.

NTE Electronics, Inc.

Series

*

-

MT

SC

X

CB

H

SDF

ML

KM

V

B

C

S

K

N

SA

E

T

F

KG

AC

Y

A5MC

HCTF

K10B

K2B

Komatsuliteu2122, AA

Komatsuliteu2122, HC

Komatsuliteu2122, KCA

Komatsuliteu2122, LC

Komatsuliteu2122, NR

L50

MHP-TA

MHP-TAC

MHP-TAM

MHP-TAT18

MTR1

MTS1

MU

MWS1

MWS2

RTP

RTS

SW-1

XG

Product Status

Active

Discontinued at Digi-Key

Not For New Designs

Obsolete

Quantity Available Price Series Product Status PackageTypeHolding TemperatureRated Functioning TemperatureReset TemperatureVoltage Rating - ACVoltage Rating - DCCurrent Rating (Amps)Approval AgencyMaximum Temperature LimitPackage / Case

Y

Active

Bulk

Fuse

103°C (217°F)

130°C (266°F)

-

300

-

5 A

cUL, TUV, UL

200°C (392°F)

Y

Active

Bulk

Fuse

89°C (192°F)

115°C (239°F)

-

250

-

5 A

CCC, Cul, KTL, PSE, UL, VDE

200°C (392°F)

XG

Active

Bulk

Fuse

61°C (142°F)

86°C (187°F)

-

250

60

3 A

CCC, cUL, PSE, TUV, UL

200°C (392°F)

XG

Active

Bulk

Fuse

79°C (174°F)

102°C (216°F)

-

250

60

3 A

CCC, cUL, PSE, TUV, UL

200°C (392°F)

X

Active

Bulk

Fuse

126°C (259°F)

150°C (302°F)

-

250

-

3 A

CCC, cUL, KC, PSE, UL, VDE

200°C (392°F)

X

Active

Bulk

Fuse

121°C (250°F)

145°C (293°F)

-

250

60

4 A

CCC, cUL, KC, PSE, UL, VDE

200°C (392°F)

V

Active

Bulk

Fuse

61°C (142°F)

86°C (187°F)

-

250

60

2.5 A

CCC, KTL, PSE, TUV

200°C (392°F)

V

Active

Bulk

Fuse

79°C (174°F)

102°C (216°F)

-

250

50

1 A

CCC, KTL, PSE, TUV

200°C (392°F)

SW-1

Active

Bag

Fuse

-

-

-

250

-

10 A

CCC, cUL, PSE, TUV, VDE, UL

-

SW-1

Active

Bag

Fuse

178°C (352°F)

216°C (421°F)

-

250

-

10 A

CCC, cUL, PSE, TUV, VDE, UL

-

SW-1

Active

Bag

Fuse

119°C (246°F)

144°C (291°F)

-

250

-

10 A

PSE

-

SW-1

Active

Bag

Fuse

103°C (217°F)

128°C (262°F)

-

250

-

10 A

CCC, cUL, PSE, TUV, VDE, UL

-

SW-1

Active

Bag

Fuse

193°C (379°F)

240°C (464°F)

-

250

-

10 A

CCC, cUL, PSE, TUV, VDE, UL

-

SW-1

Active

Bag

Fuse

159°C (318°F)

184°C (363°F)

-

250

-

10 A

CCC, cUL, PSE, TUV, VDE, UL

-

SW-1

Active

Bag

Fuse

165°C (329°F)

195°C (383°F)

-

250

-

10 A

CCC, cUL, PSE, TUV, VDE, UL

-

SW-1

Active

Bag

Fuse

162°C (324°F)

192°C (378°F)

-

250

-

10 A

PSE

-

SW-1

Active

Bag

Fuse

144°C (291°F)

167°C (333°F)

-

250

-

10 A

CCC, cUL, PSE, TUV, VDE, UL

-

SW-1

Active

Bag

Fuse

144°C (291°F)

169°C (336°F)

-

250

-

10 A

CCC, cUL, PSE, TUV, VDE, UL

-

SW-1

Active

Bag

Fuse

127°C (261°F)

152°C (306°F)

-

250

-

10 A

CCC, cUL, PSE, TUV, VDE, UL

-

SW-1

Active

Bag

Fuse

100°C (212°F)

126°C (259°F)

-

250

-

10 A

CCC, cUL, PSE, TUV, VDE, UL

-

SW-1

Active

Bag

Fuse

114°C (237°F)

139°C (282°F)

-

250

-

10 A

CCC, cUL, PSE, TUV, VDE, UL

-

SW-1

Active

Bag

Fuse

94°C (201°F)

119°C (246°F)

-

250

-

10 A

cUL, PSE, TUV, VDE, UL

-

SW-1

Active

Bag

Fuse

84°C (183°F)

109°C (228°F)

-

250

-

10 A

CCC, cUL, PSE, TUV, VDE, UL

-

SW-1

Active

Bag

Fuse

57°C (135°F)

84°C (183°F)

-

250

-

10 A

CCC, cUL, PSE, TUV, VDE, UL

-

SW-1

Active

Bag

Fuse

75°C (167°F)

100°C (212°F)

-

250

-

10 A

CCC, cUL, PSE, TUV, VDE, UL

-

SW-1

Active

Bag

Fuse

52°C (126°F)

77°C (171°F)

-

250

-

10 A

CCC, cUL, PSE, TUV, VDE, UL

-

SW-1

Active

Bag

Fuse

73°C (163°F)

98°C (208°F)

-

250

-

10 A

CCC, cUL, PSE, TUV, VDE, UL

-

SW-1

Active

Bag

Fuse

47°C (117°F)

72°C (162°F)

-

250

-

10 A

CCC, cUL, PSE, TUV, VDE, UL

-

*

Active

Bulk

-

-

-

-

-

-

-

-

-

-

Active

Bulk

Fuse

210°C (410°F)

-

-

-

-

15 A

-

-

*

Active

Bulk

-

-

-

-

-

-

-

-

-

T

Active

Bulk

Fuse

106°C (223°F)

136°C (277°F)

-

250

-

15 A

CCC, cUL, PSE, UL, VDE

200°C (392°F)

T

Active

Bulk

Fuse

85°C (185°F)

115°C (239°F)

-

250

-

15 A

CCC, cUL, PSE, UL, VDE

200°C (392°F)

SDF

Active

Bulk

Fuse

200°C (392°F)

240°C (464°F)

-

250

-

10 A

CCC, cUL, PSE, UL, VDE

-

SDF

Active

Bulk

Fuse

193°C (379°F)

228°C (442°F)

-

250

-

10 A

CCC, cUL, PSE, UL, VDE

-

SDF

Discontinued at Digi-Key

Bulk

Fuse

220°C (428°F)

-

-

-

-

-

-

-

SDF

Active

Bulk

Fuse

191°C (376°F)

216°C (421°F)

-

250

-

10 A

CCC, cUL, PSE, UL, VDE

-

SDF

Active

Bulk

Fuse

162°C (324°F)

192°C (378°F)

-

250

-

10 A

CCC, cUL, PSE, UL, VDE

-

SDF

Active

Bulk

Fuse

160°C (320°F)

184°C (363°F)

-

250

-

10 A

CCC, cUL, PSE, UL, VDE

-

SDF

Active

Bulk

Fuse

146°C (295°F)

170°C (338°F)

-

250

-

10 A

CCC, cUL, PSE, UL, VDE

-

SDF

Active

Bulk

Fuse

128°C (262°F)

152°C (306°F)

-

250

-

10 A

CCC, cUL, PSE, UL, VDE

-

SDF

Active

Bulk

Fuse

120°C (248°F)

144°C (291°F)

-

250

-

10 A

CCC, cUL, PSE, UL, VDE

-

SDF

Active

Bulk

Fuse

117°C (243°F)

141°C (286°F)

-

250

-

10 A

CCC, cUL, PSE, UL, VDE

-

SDF

Active

Bulk

Fuse

106°C (223°F)

128°C (262°F)

-

250

-

10 A

CCC, cUL, PSE, UL, VDE

-

SDF

Active

Bulk

Fuse

95°C (203°F)

119°C (246°F)

-

250

-

10 A

CCC, cUL, PSE, UL, VDE

-

SDF

Active

Bulk

Fuse

86°C (187°F)

110°C (230°F)

-

250

-

10 A

CCC, cUL, PSE, UL, VDE

-

SDF

Active

Bulk

Fuse

80°C (176°F)

104°C (219°F)

-

250

-

10 A

CCC, cUL, PSE, UL, VDE

-

SDF

Active

Bulk

Fuse

78°C (174°F)

100°C (212°F)

-

250

-

10 A

CCC, cUL, PSE, UL, VDE

-

SDF

Active

Bulk

Fuse

76°C (169°F)

98°C (208°F)

-

250

-

10 A

CCC, cUL, PSE, UL, VDE

-

SDF

Active

Bulk

Fuse

67°C (156°F)

91°C (196°F)

-

250

-

10 A

CCC, cUL, PSE, UL, VDE

-

SDF

Active

Bulk

Fuse

60°C (140°F)

84°C (183°F)

-

250

-

10 A

CCC, cUL, PSE, UL, VDE

-

SDF

Active

Bulk

Fuse

55°C (131°F)

77°C (171°F)

-

250

-

10 A

CCC, cUL, PSE, UL, VDE

-

SDF

Active

Bulk

Fuse

50°C (122°F)

72°C (162°F)

-

250

-

10 A

CCC, cUL, PSE, UL, VDE

-

SDF

Active

Bulk

Fuse

42°C (108°F)

66°C (151°F)

-

250

-

10 A

CCC, cUL, PSE, UL, VDE

-

SC

Active

Tape & Reel (TR) Cut Tape (CT) Digi-Reel®

Breaker

25°C (77°F)

85°C (185°F)

40°C (104°F)

-

28

25 A

cUL, TUV, UL

-

SC

Active

Tape & Reel (TR) Cut Tape (CT) Digi-Reel®

Breaker

25°C (77°F)

85°C (185°F)

40°C (104°F)

-

28

25 A

cUL, TUV, UL

-

SC

Active

Tape & Reel (TR) Cut Tape (CT) Digi-Reel®

Breaker

25°C (77°F)

82°C (180°F)

40°C (104°F)

-

28

25 A

cUL, TUV, UL

-

SC

Active

Tape & Reel (TR) Cut Tape (CT) Digi-Reel®

Breaker

25°C (77°F)

82°C (180°F)

40°C (104°F)

-

28

25 A

cUL, TUV, UL

-

SC

Active

Tape & Reel (TR) Cut Tape (CT) Digi-Reel®

Breaker

25°C (77°F)

77°C (171°F)

40°C (104°F)

-

28

25 A

cUL, TUV, UL

-

SC

Active

Tape & Reel (TR) Cut Tape (CT) Digi-Reel®

Breaker

25°C (77°F)

77°C (171°F)

40°C (104°F)

-

28

25 A

cUL, TUV, UL

-

SC

Active

Tape & Reel (TR) Cut Tape (CT) Digi-Reel®

Breaker

25°C (77°F)

72°C (162°F)

40°C (104°F)

-

28

25 A

cUL, TUV, UL

-

SC

Active

Tape & Reel (TR) Cut Tape (CT) Digi-Reel®

Breaker

25°C (77°F)

72°C (162°F)

40°C (104°F)

-

28

25 A

cUL, TUV, UL

-

SA

Active

Tape & Reel (TR) Cut Tape (CT) Digi-Reel®

Breaker

-

85°C (185°F)

40°C (104°F)

-

28

25 A

cUL, TUV, UL

-

SA

Obsolete

Tape & Reel (TR) Cut Tape (CT) Digi-Reel®

Breaker

-

85°C (185°F)

40°C (104°F)

-

28

12 A

cUL, TUV, UL

-

SA

Active

Tape & Reel (TR) Cut Tape (CT) Digi-Reel®

Breaker

-

82°C (180°F)

40°C (104°F)

-

28

25 A

cUL, TUV, UL

-

SA

Obsolete

Tape & Reel (TR) Cut Tape (CT) Digi-Reel®

Breaker

-

82°C (180°F)

40°C (104°F)

-

28

12 A

cUL, TUV, UL

-

SA

Active

Tape & Reel (TR) Cut Tape (CT) Digi-Reel®

Breaker

-

77°C (171°F)

40°C (104°F)

-

28

25 A

cUL, TUV, UL

-

SA

Obsolete

Tape & Reel (TR) Cut Tape (CT) Digi-Reel®

Breaker

-

77°C (171°F)

40°C (104°F)

-

28

12 A

cUL, TUV, UL

-

SA

Active

Tape & Reel (TR) Cut Tape (CT) Digi-Reel®

Breaker

-

72°C (162°F)

40°C (104°F)

-

28

25 A

cUL, TUV, UL

-

SA

Obsolete

Tape & Reel (TR) Cut Tape (CT) Digi-Reel®

Breaker

-

72°C (162°F)

40°C (104°F)

-

28

12 A

cUL, TUV, UL

-

S

Active

Bulk

Fuse

85°C (185°F)

115°C (239°F)

-

250

-

10 A

CCC, cUL, PSE, UL, VDE

200°C (392°F)

S

Active

Bulk

Fuse

72°C (162°F)

102°C (216°F)

-

250

-

5 A

CCC, cUL, PSE, UL, VDE

200°C (392°F)

RTS

Active

Tape & Reel (TR) Cut Tape (CT) Digi-Reel®

Fuse

-

-

-

-

60

170 A

UL

-

RTS

Active

Tape & Reel (TR) Cut Tape (CT) Digi-Reel®

Fuse

-

-

-

-

60

170 A

UL

-

RTP

Obsolete

Tape & Reel (TR) Cut Tape (CT) Digi-Reel®

Fuse

-

205°C (401°F)

-

-

32

100 A

-

-

-

Active

Tape & Box (TB)

Fuse

-

-

-

-

16

500 A

-

260°C (500°F)

*

Active

Bulk

-

-

-

-

-

-

-

-

-

-

Active

Bag

Fuse

200°C (392°F)

240°C (464°F)

-

250

-

15 A

cUR, UL, VDE

-

-

Active

Bag

Fuse

-

228°C (442°F)

-

250

-

15 A

cUR, UL, VDE

-

-

Active

Bag

Fuse

191°C (376°F)

216°C (421°F)

-

250

-

15 A

cUL, UL, VDE

-

-

Active

Bag

Fuse

162°C (324°F)

192°C (378°F)

-

250

-

15 A

cUL, UL, VDE

-

-

Active

Bag

Fuse

160°C (320°F)

184°C (363°F)

-

250

-

15 A

cUR, UL, VDE

-

-

Active

Bag

Fuse

146°C (295°F)

170°C (338°F)

-

250

-

15 A

cUR, UL, VDE

-

-

Active

Bag

Fuse

128°C (262°F)

152°C (306°F)

-

250

-

15 A

cUR, UL, VDE

-

-

Active

Bag

Fuse

110°C (230°F)

142°C (287°F)

-

250

-

15 A

cUR, UL, VDE

-

-

Active

Bag

Fuse

106°C (223°F)

128°C (263°F)

-

250

-

15 A

cUR, UL, VDE

-

-

Active

Bag

Fuse

94°C (201°F)

121°C (250°F)

-

250

-

15 A

cUR, UL, VDE

-

-

Active

Bag

Fuse

-

117°C (243°F)

-

250

-

15 A

cUR, UL, VDE

-

-

Active

Bag

Fuse

88°C (190°F)

109°C (228°F)

-

250

-

15 A

UL, VDE

-

-

Active

Bag

Fuse

80°C (176°F)

104°C (219°F)

-

250

-

15 A

cUL, UL, VDE

-

-

Active

Bag

Fuse

-

100°C (212°F)

-

250

-

15 A

cUL, UL, VDE

-

-

Active

Bag

Fuse

76°C (169°F)

98°C (208°F)

-

250

-

15 A

cUL, UL, VDE

-

-

Active

Bag

Fuse

-

93°C (200°F)

-

250

-

15 A

UL, VDE

-

-

Active

Bag

Fuse

-

87°C (189°F)

-

250

-

15 A

cUR, UL, VDE

-

-

Active

Bag

Fuse

60°C (140°F)

84°C (183°F)

-

250

-

15 A

cUL, UL, VDE

-

-

Active

Bag

Fuse

-

77°C (171°F)

-

250

-

15 A

cUR, UL, VDE

-

-

Active

Bag

Fuse

50°C (122°F)

72°C (162°F)

-

250

-

15 A

cUL, UL, VDE

-

-

Active

Bag

Fuse

42°C (108°F)

66°C (151°F)

-

250

-

15 A

cUR, UL, VDE

-

-

Active

Bag

Fuse

123°C (253°F)

150°C (302°F)

-

250

-

5 A

UL, VDE

200°C (392°F)

-

Active

Bag

Fuse

118°C (244°F)

145°C (293°F)

-

250

-

5 A

UL, VDE

200°C (392°F)

-

Active

Bag

Fuse

111°C (232°F)

136°C (277°F)

-

250

-

5 A

UL, VDE

200°C (392°F)

-

Active

Bag

Fuse

103°C (217°F)

130°C (266°F)

-

250

-

5 A

UL, VDE

200°C (392°F)

-

Active

Bag

Fuse

89°C (192°F)

115°C (239°F)

-

250

-

5 A

UL, VDE

200°C (392°F)

-

Active

Bag

Fuse

77°C (171°F)

102°C (216°F)

-

250

-

5 A

UL, VDE

200°C (392°F)

-

Active

Bag

Fuse

61°C (142°F)

86°C (187°F)

-

250

-

5 A

UL, VDE

200°C (392°F)

-

Active

Bag

Fuse

53°C (127°F)

76°C (168°F)

-

250

-

5 A

UL, VDE

200°C (392°F)

Komatsuliteu2122, NR

Active

Bag

Breaker

-

85°C (185°F)

40°C (104°F)

-

28

12 A

cUL, TUV, UL

-

Komatsuliteu2122, NR

Active

Bag

Breaker

-

85°C (185°F)

40°C (104°F)

-

28

25 A

cUL, TUV, UL

-

Komatsuliteu2122, NR

Active

Bag

Breaker

-

82°C (180°F)

40°C (104°F)

-

28

12 A

cUL, TUV, UL

-

Komatsuliteu2122, NR

Active

Bag

Breaker

-

82°C (180°F)

40°C (104°F)

-

28

25 A

cUL, TUV, UL

-

Komatsuliteu2122, NR

Active

Bag

Breaker

-

77°C (171°F)

40°C (104°F)

-

28

12 A

cUL, TUV, UL

-

Komatsuliteu2122, NR

Active

Bag

Breaker

-

77°C (171°F)

40°C (104°F)

-

28

25 A

cUL, TUV, UL

-

Komatsuliteu2122, NR

Active

Bag

Breaker

-

72°C (162°F)

40°C (104°F)

-

28

12 A

cUL, TUV, UL

-

Komatsuliteu2122, NR

Active

Bag

Breaker

-

72°C (162°F)

40°C (104°F)

-

28

25 A

cUL, TUV, UL

-

MWS2

Active

Bag

Fuse

70°C (158°F)

100°C (212°F)

-

250

-

20 A

-

180°C (356°F)

MWS2

Obsolete

Bag

Fuse

-

-

-

-

-

-

-

-

MWS2

Obsolete

Bag

Fuse

-

-

-

-

-

-

-

-

MWS2

Active

Bag

Fuse

80°C (176°F)

110°C (230°F)

-

250

-

20 A

-

180°C (356°F)

MWS1

Active

Bag

Fuse

70°C (158°F)

100°C (212°F)

-

250

-

15 A

-

180°C (356°F)

MWS1

Active

Bag

Fuse

110°C (230°F)

143°C (289°F)

-

250

-

15 A

-

180°C (356°F)

MWS1

Active

Bag

Fuse

100°C (212°F)

130°C (266°F)

-

250

-

15 A

-

180°C (356°F)

MWS1

Active

Bag

Fuse

80°C (176°F)

110°C (230°F)

-

250

-

15 A

-

180°C (356°F)

MTS1

Active

Bag

Fuse

70°C (158°F)

100°C (212°F)

-

250

-

5 A

-

180°C (356°F)

MTS1

Active

Bag

Fuse

110°C (230°F)

143°C (289°F)

-

250

-

5 A

-

180°C (356°F)

MTS1

Active

Bag

Fuse

100°C (212°F)

130°C (266°F)

-

250

-

5 A

-

180°C (356°F)

MTS1

Active

Bag

Fuse

80°C (176°F)

110°C (230°F)

-

250

-

5 A

-

180°C (356°F)

MTR1

Active

Bag

Fuse

70°C (158°F)

98°C (208°F)

-

250

-

3 A

-

180°C (356°F)

MTR1

Obsolete

Bag

Fuse

-

-

-

-

-

3 A

-

-

MTR1

Obsolete

Bag

Fuse

-

-

-

-

-

3 A

-

-

MTR1

Obsolete

Bag

Fuse

100°C (212°F)

130°C (266°F)

-

250

-

3 A

-

180°C (356°F)

MTR1

Active

Bag

Fuse

80°C (176°F)

108°C (226°F)

-

250

-

3 A

-

180°C (356°F)

MT

Active

Bulk

Fuse

99°C (210°F)

115°C (239°F)

-

250

-

1 A

UL, VDE

200°C (392°F)

MHP-TAT18

Active

Bag

Breaker

-

90°C (194°F)

40°C (104°F)

-

28

30 A

cURus

-

MHP-TAT18

Active

Bulk

Breaker

-

90°C (194°F)

40°C (104°F)

-

28

30 A

cURus

-

MHP-TAT18

Active

Bag

Breaker

-

85°C (185°F)

40°C (104°F)

-

28

30 A

cURus

-

MHP-TAT18

Active

Bulk

Breaker

-

85°C (185°F)

40°C (104°F)

-

28

30 A

cURus

-

MHP-TAT18

Active

Bag

Breaker

-

82°C (180°F)

40°C (104°F)

-

28

30 A

cURus

-

MHP-TAT18

Active

Bulk

Breaker

-

82°C (180°F)

40°C (104°F)

-

28

30 A

cURus

-

MHP-TAT18

Active

Bag

Breaker

-

77°C (171°F)

40°C (104°F)

-

28

30 A

cURus

-

MHP-TAT18

Active

Bulk

Breaker

-

77°C (171°F)

40°C (104°F)

-

28

30 A

cURus

-

MHP-TAT18

Active

Bag

Breaker

-

72°C (162°F)

40°C (104°F)

-

28

30 A

cURus

-

MHP-TAT18

Active

Bulk

Breaker

-

72°C (162°F)

40°C (104°F)

-

28

30 A

cURus

-

MHP-TAM

Active

Bag

Breaker

-

85°C (185°F)

40°C (104°F)

-

9

12 A

cUL, UL

-

MHP-TAM

Active

Bag

Breaker

-

82°C (180°F)

40°C (104°F)

-

9

12 A

cUL, UL

-

MHP-TAM

Active

Bag

Breaker

-

77°C (171°F)

40°C (104°F)

-

9

12 A

cUL, UL

-

MHP-TAM

Active

Bag

Breaker

-

72°C (162°F)

40°C (104°F)

-

9

12 A

cUL, UL

-

MHP-TAM

Active

Bulk

Breaker

-

90°C (194°F)

40°C (104°F)

-

9

12 A

cUL, UL

-

MHP-TAM

Active

Bag

Breaker

-

90°C (194°F)

40°C (104°F)

-

9

12 A

cUL, UL

-

MHP-TAM

Active

Bulk

Breaker

-

85°C (185°F)

40°C (104°F)

-

9

12 A

cUL, UL

-

MHP-TAM

Active

Bag

Breaker

-

85°C (185°F)

40°C (104°F)

-

9

12 A

cUL, UL

-

MHP-TAM

Active

Bulk

Breaker

-

82°C (180°F)

40°C (104°F)

-

9

12 A

cUL, UL

-

MHP-TAM

Active

Bag

Breaker

-

82°C (180°F)

40°C (104°F)

-

9

12 A

cUL, UL

-

MHP-TAM

Active

Bulk

Breaker

-

77°C (171°F)

40°C (104°F)

-

9

12 A

cUL, UL

-

MHP-TAM

Active

Bag

Breaker

-

77°C (171°F)

40°C (104°F)

-

9

12 A

cUL, UL

-

MHP-TAM

Active

Bulk

Breaker

-

72°C (162°F)

40°C (104°F)

-

9

12 A

cUL, UL

-

MHP-TAM

Active

Bag

Breaker

-

72°C (162°F)

40°C (104°F)

-

9

12 A

cUL, UL

-

MHP-TAC

Active

Bulk

Breaker

-

85°C (185°F)

40°C (104°F)

-

12

25 A

-

-

MHP-TAC

Not For New Designs

Bulk

Breaker

-

85°C (185°F)

40°C (104°F)

-

12

25 A

-

-

MHP-TAC

Active

Bulk

Breaker

-

82°C (180°F)

40°C (104°F)

-

12

25 A

-

-

MHP-TAC

Not For New Designs

Bulk

Breaker

-

82°C (180°F)

40°C (104°F)

-

12

25 A

-

-

MHP-TAC

Active

Bulk

Breaker

-

77°C (171°F)

40°C (104°F)

-

12

25 A

-

-

MHP-TAC

Not For New Designs

Bulk

Breaker

-

77°C (171°F)

40°C (104°F)

-

12

25 A

-

-

MHP-TAC

Active

Bulk

Breaker

-

72°C (162°F)

40°C (104°F)

-

12

25 A

-

-

MHP-TAC

Not For New Designs

Bulk

Breaker

-

72°C (162°F)

40°C (104°F)

-

12

25 A

-

-

MHP-TAC

Active

Bulk

Breaker

-

90°C (194°F)

40°C (104°F)

-

12

25 A

-

-

MHP-TAC

Not For New Designs

Bulk

Breaker

-

90°C (194°F)

40°C (104°F)

-

12

25 A

-

-

MHP-TAC

Active

Bulk

Breaker

-

85°C (185°F)

40°C (104°F)

-

12

25 A

-

-

MHP-TAC

Not For New Designs

Bulk

Breaker

-

85°C (185°F)

40°C (104°F)

-

12

25 A

-

-

MHP-TAC

Active

Bulk

Breaker

-

82°C (180°F)

40°C (104°F)

-

12

25 A

-

-

MHP-TAC

Not For New Designs

Bulk

Breaker

-

82°C (180°F)

40°C (104°F)

-

12

25 A

-

-

MHP-TAC

Active

Bulk

Breaker

-

77°C (171°F)

40°C (104°F)

-

12

25 A

-

-

MHP-TAC

Not For New Designs

Bulk

Breaker

-

77°C (171°F)

40°C (104°F)

-

12

25 A

-

-

MHP-TAC

Active

Bulk

Breaker

-

72°C (162°F)

40°C (104°F)

-

12

25 A

-

-

MHP-TAC

Not For New Designs

Bulk

Breaker

-

72°C (162°F)

40°C (104°F)

-

12

25 A

-

-

MHP-TA

Obsolete

Bag

Breaker

-

85°C (185°F)

40°C (104°F)

-

9

12 A

UL

-

MHP-TA

Obsolete

Bag

Breaker

-

82°C (180°F)

40°C (104°F)

-

9

12 A

UL

-

MHP-TA

Obsolete

Bag

Breaker

-

77°C (171°F)

40°C (104°F)

-

9

12 A

UL

-

MHP-TA

Obsolete

Bag

Breaker

-

72°C (162°F)

40°C (104°F)

-

9

12 A

UL

-

MHP-TA

Obsolete

Bag

Breaker

-

90°C (194°F)

40°C (104°F)

-

9

12 A

UL

-

MHP-TA

Obsolete

Bag

Breaker

-

85°C (185°F)

40°C (104°F)

-

9

12 A

UL

-

MHP-TA

Obsolete

Bag

Breaker

-

82°C (180°F)

40°C (104°F)

-

9

12 A

UL

-

MHP-TA

Obsolete

Bag

Breaker

-

77°C (171°F)

40°C (104°F)

-

9

12 A

UL

-

MHP-TA

Obsolete

Bag

Breaker

-

72°C (162°F)

40°C (104°F)

-

9

12 A

UL

-

Komatsuliteu2122, LC

Active

Bag

Breaker

-

85°C (185°F)

40°C (104°F)

-

28

5 A

cUL, TUV, UL

-

Komatsuliteu2122, LC

Active

Bag

Breaker

-

82°C (180°F)

40°C (104°F)

-

28

5 A

cUL, TUV, UL

-

Komatsuliteu2122, LC

Active

Bag

Breaker

-

77°C (171°F)

40°C (104°F)

-

28

5 A

cUL, TUV, UL

-

Komatsuliteu2122, LC

Active

Bag

Breaker

-

72°C (162°F)

40°C (104°F)

-

28

5 A

cUL, TUV, UL

-

L50

Active

Bulk

Fuse

200°C (392°F)

240°C (464°F)

-

250

-

15 A

VDE

260°C (500°F)

L50

Active

Bulk

Fuse

200°C (392°F)

240°C (464°F)

-

250

-

15 A

VDE

260°C (500°F)

L50

Active

Bag

Fuse

160°C (320°F)

184°C (363°F)

-

250

-

15 A

-

214°C (417°F)

L50

Active

Bag

Fuse

146°C (295°F)

170°C (338°F)

-

250

-

15 A

-

190°C (374°F)

L50

Active

Bag

Fuse

142°C (288°F)

167°C (333°F)

-

250

-

15 A

-

210°C (410°F)

L50

Active

Bag

Fuse

128°C (262°F)

152°C (306°F)

-

250

-

15 A

-

175°C (347°F)

L50

Active

Bag

Fuse

120°C (248°F)

144°C (291°F)

-

250

-

15 A

-

250°C (482°F)

L50

Active

Bag

Fuse

117°C (243°F)

141°C (286°F)

-

250

-

15 A

-

171°C (340°F)

L50

Active

Bag

Fuse

106°C (223°F)

128°C (262°F)

-

250

-

15 A

-

155°C (311°F)

L50

Active

Bag

Fuse

95°C (203°F)

119°C (246°F)

-

250

-

15 A

-

170°C (338°F)

L50

Active

Bag

Fuse

88°C (190°F)

110°C (230°F)

-

250

-

15 A

-

140°C (284°F)

L50

Active

Bag

Fuse

80°C (176°F)

104°C (219°F)

-

250

-

15 A

-

150°C (302°F)

L50

Active

Bag

Fuse

78°C (174°F)

100°C (212°F)

-

250

-

15 A

-

250°C (482°F)

L50

Active

Bag

Fuse

76°C (169°F)

98°C (208°F)

-

250

-

15 A

-

130°C (266°F)

L50

Active

Bag

Fuse

67°C (156°F)

91°C (196°F)

-

250

-

15 A

-

121°C (250°F)

L50

Active

Bag

Fuse

60°C (140°F)

84°C (183°F)

-

250

-

15 A

-

114°C (237°F)

L50

Active

Bag

Fuse

55°C (131°F)

77°C (171°F)

-

250

-

15 A

-

110°C (230°F)

L50

Active

Bag

Fuse

50°C (122°F)

72°C (162°F)

-

250

-

15 A

-

110°C (230°F)

L50

Active

Bulk

Fuse

162°C (324°F)

192°C (378°F)

-

250

-

15 A

UL

-

KM

Active

Bulk

Fuse

126°C (259°F)

150°C (302°F)

-

300

-

2 A

cUL, TUL, UL

200°C (392°F)

KG

Active

Bulk

Fuse

111°C (232°F)

133°C (271°F)

-

250

-

2 A

CCC, cUL, PSE, TUV, UL

200°C (392°F)

KG

Active

Bulk

Fuse

79°C (174°F)

102°C (216°F)

-

250

60

2 A

CCC, cUL, PSE, TUV, UL

200°C (392°F)

Komatsuliteu2122, KCA

Obsolete

Bag

Breaker

-

85°C (185°F)

40°C (104°F)

-

28

25 A

cUL, TUV, UL

-

Komatsuliteu2122, KCA

Obsolete

Bag

Breaker

-

82°C (180°F)

40°C (104°F)

-

28

25 A

cUL, TUV, UL

-

Komatsuliteu2122, KCA

Obsolete

Bag

Breaker

-

77°C (171°F)

40°C (104°F)

-

28

25 A

cUL, TUV, UL

-

Komatsuliteu2122, KCA

Obsolete

Bag

Breaker

-

72°C (162°F)

40°C (104°F)

-

28

25 A

cUL, TUV, UL

-

K

Active

Bulk

Fuse

126°C (259°F)

150°C (302°F)

-

250

-

2 A

CCC, cUL, KC, PSE, UL, VDE

200°C (392°F)

K

Active

Bulk

Fuse

121°C (250°F)

145°C (293°F)

-

250

60

4 A

CCC, cUL, KC, PSE, UL, VDE

200°C (392°F)

K2B

Active

Bulk

Fuse

115°C (239°F)

150°C (302°F)

-

250

-

2 A

CCC, VDE

180°C (356°F)

K2B

Active

Bulk

Fuse

110°C (230°F)

145°C (293°F)

-

250

-

2 A

CCC, VDE

180°C (356°F)

K2B

Active

Bulk

Fuse

105°C (221°F)

140°C (284°F)

-

250

-

2 A

CCC, VDE

180°C (356°F)

K2B

Active

Bulk

Fuse

105°C (221°F)

135°C (275°F)

-

250

-

2 A

CCC

180°C (356°F)

K2B

Active

Bulk

Fuse

100°C (212°F)

130°C (266°F)

-

250

-

2 A

CCC, VDE

180°C (356°F)

K2B

Active

Bulk

Fuse

95°C (203°F)

125°C (257°F)

-

250

-

2 A

CCC, VDE

180°C (356°F)

K2B

Active

Bulk

Fuse

-

123°C (253°F)

-

250

-

2 A

-

-

K2B

Active

Bulk

Fuse

-

120°C (248°F)

-

250

-

2 A

-

-

K2B

Active

Bulk

Fuse

80°C (176°F)

115°C (239°F)

-

250

-

2 A

CCC, VDE

180°C (356°F)

K2B

Active

Bulk

Fuse

-

110°C (230°F)

-

250

-

2 A

-

-

K2B

Active

Bulk

Fuse

75°C (167°F)

105°C (221°F)

-

250

-

2 A

CCC

180°C (356°F)

K2B

Active

Bulk

Fuse

-

100°C (212°F)

-

250

-

2 A

-

-

K2B

Active

Bulk

Fuse

-

95°C (203°F)

-

250

-

2 A

-

-

K2B

Active

Bulk

Fuse

-

90°C (194°F)

-

250

-

2 A

-

-

K2B

Active

Bulk

Fuse

-

83°C (181°F)

-

250

-

2 A

-

-

K10B

Active

Bulk

Fuse

190°C (374°F)

240°C (464°F)

-

250

-

10 A

CCC, cURus, VDE

350°C (660°C)

K10B

Active

Bulk

Fuse

190°C (374°F)

228°C (442°F)

-

250

-

10 A

CCC, cURus, VDE

300°C (572°F)

K10B

Active

Bulk

Fuse

160°C (320°F)

184°C (363°F)

-

250

-

10 A

CCC, VDE

214°C (417°F)

K10B

Active

Bulk

Fuse

146°C (295°F)

167°C (333°F)

-

250

-

10 A

CCC, cURus, VDE

190°C (374°F)

K10B

Active

Bulk

Fuse

128°C (262°F)

152°C (306°F)

-

250

-

10 A

CCC, cURus, VDE

176°C (349°F)

K10B

Active

Bulk

Fuse

94°C (201°F)

121°C (250°F)

-

250

-

10 A

CCC

150°C (302°F)

K10B

Active

Bulk

Fuse

88°C (190°F)

110°C (230°F)

-

250

-

10 A

CCC, cURus, VDE

140°C (284°F)

K10B

Active

Bulk

Fuse

60°C (140°F)

84°C (183°F)

-

250

-

10 A

CCC

150°C (302°F)

K10B

Active

Bulk

Fuse

55°C (131°F)

77°C (171°F)

-

250

-

10 A

CCC, cURus, VDE

120°C (248°F)

K10B

Active

Bulk

Fuse

45°C (113°F)

72°C (162°F)

-

250

-

10 A

cURus, VDE

-

*

Active

Bulk

-

-

-

-

-

-

-

-

-

HCTF

Active

Tape & Reel (TR) Cut Tape (CT)

Fuse

160°C (320°F)

235°C (455°F)

-

-

24

50 A

-

-

HCTF

Obsolete

Tape & Reel (TR) Cut Tape (CT)

Fuse

160°C (320°F)

235°C (455°F)

-

-

24

55 A

-

-

RTP

Obsolete

Tape & Reel (TR) Cut Tape (CT) Digi-Reel®

Fuse

-

228°C (442°F)

-

-

16

500 A

-

150°C (302°F)

RTP

Discontinued at Digi-Key

Tape & Reel (TR) Cut Tape (CT) Digi-Reel®

Fuse

-

228°C (442°F)

-

-

16

500 A

-

150°C (302°F)

Komatsuliteu2122, HC

Active

Bag

Breaker

-

90°C (194°F)

40°C (104°F)

-

28

25 A

cUL, TUV, UL

-

Komatsuliteu2122, HC

Active

Bag

Breaker

-

85°C (185°F)

40°C (104°F)

-

28

25 A

cUL, TUV, UL

-

Komatsuliteu2122, HC

Active

Bag

Breaker

-

82°C (180°F)

40°C (104°F)

-

28

25 A

cUL, TUV, UL

-

Komatsuliteu2122, HC

Active

Bag

Breaker

-

77°C (171°F)

40°C (104°F)

-

28

25 A

cUL, TUV, UL

-

Komatsuliteu2122, HC

Active

Bag

Breaker

-

72°C (162°F)

40°C (104°F)

-

28

25 A

cUL, TUV, UL

-

H

Active

Bulk

Fuse

91°C (196°F)

115°C (239°F)

-

250

50

2 A

CCC, cUL, KTL, PSE, TUV

200°C (392°F)

H

Active

Bulk

Fuse

79°C (174°F)

102°C (216°F)

-

250

50

2 A

CCC, KTL, PSE, TUV

200°C (392°F)

F

Active

Bulk

Fuse

126°C (259°F)

150°C (302°F)

-

250

-

1 A

CCC, cUL, KC, PSE, TUV, UL, VDE

200°C (392°F)

F

Active

Bulk

Fuse

106°C (223°F)

130°C (266°F)

-

250

60

3 A

CCC, cUL, KC, PSE, TUV, UL, VDE

200°C (392°F)

MU

Obsolete

Box

Fuse

55°C (131°F)

92°C (198°F)

-

-

32

4 A

UL

135°C (275°F)

MT

Obsolete

Bulk

Fuse

70°C (158°F)

102°C (216°F)

-

-

50

2 A

UL

150°C (302°F)

MT

Obsolete

Bulk

Fuse

70°C (158°F)

102°C (216°F)

-

-

50

2 A

UL

150°C (302°F)

MT

Obsolete

Bulk

Fuse

70°C (158°F)

102°C (216°F)

-

-

50

2 A

UL

150°C (302°F)

MT

Obsolete

Bulk

Fuse

65°C (149°F)

98°C (208°F)

-

-

50

2 A

UL

150°C (302°F)

MT

Obsolete

Bulk

Fuse

65°C (149°F)

98°C (208°F)

-

-

50

2 A

UL

150°C (302°F)

MT

Obsolete

Bulk

Fuse

65°C (149°F)

98°C (208°F)

-

-

50

2 A

UL

150°C (302°F)

MT

Obsolete

Bulk

Fuse

60°C (140°F)

92°C (198°F)

-

-

50

2 A

UL

150°C (302°F)

MT

Obsolete

Bulk

Fuse

60°C (140°F)

92°C (198°F)

-

-

50

2 A

UL

150°C (302°F)

MT

Obsolete

Bulk

Fuse

60°C (140°F)

92°C (198°F)

-

-

50

2 A

UL

150°C (302°F)

ML

Obsolete

Box

-

-

-

-

-

-

-

-

-

ML

Obsolete

Box

-

-

-

-

-

-

-

-

-

-

Obsolete

Bulk

Fuse

-

-

-

-

-

-

-

-

N

Obsolete

Bulk

Fuse

135°C (275°F)

168°C (334°F)

-

250

50

2 A

BEAB, CCC, CSA, PSE, UL, VDE

200°C (392°F)

N

Obsolete

Bulk

Fuse

120°C (248°F)

145°C (293°F)

-

250

50

2 A

BEAB, CCC, CSA, PSE, UL, VDE

200°C (392°F)

N

Obsolete

Bulk

Fuse

115°C (239°F)

140°C (284°F)

-

250

50

2 A

BEAB, CCC, CSA, PSE, UL, VDE

200°C (392°F)

N

Obsolete

Box

Fuse

110°C (230°F)

139°C (282°F)

-

250

50

-

BEAB, CCC, CSA,cUL, PSE, UL, VDE

200°C (392°F)

N

Obsolete

Box

Fuse

100°C (212°F)

134°C (273°F)

-

250

50

-

BEAB, CCC, CSA,cUL, PSE, UL, VDE

200°C (392°F)

N

Obsolete

Bulk

Fuse

108°C (226°F)

133°C (271°F)

-

250

50

2 A

BEAB, CCC, CSA, PSE, UL, VDE

200°C (392°F)

N

Obsolete

Bulk

Fuse

105°C (221°F)

130°C (266°F)

-

250

50

2 A

BEAB, CCC, CSA, PSE, UL, VDE

200°C (392°F)

N

Obsolete

Bulk

Fuse

90°C (194°F)

115°C (239°F)

-

250

50

2 A

BEAB, CCC, CSA, PSE, UL, VDE

200°C (392°F)

N

Obsolete

Bulk

Fuse

90°C (194°F)

114°C (237°F)

-

250

50

2 A

BEAB, CCC, CSA, PSE, UL, VDE

200°C (392°F)

N

Obsolete

Box

Fuse

75°C (167°F)

102°C (216°F)

-

250

50

-

BEAB, CCC, CSA,cUL, PSE, UL, VDE

200°C (392°F)

N

Obsolete

Bulk

Fuse

75°C (167°F)

102°C (216°F)

-

250

50

2 A

BEAB, CCC, CSA, PSE, UL, VDE

200°C (392°F)

N

Obsolete

Box

-

-

-

-

-

-

-

-

-

N

Obsolete

Bulk

Fuse

76°C (169°F)

102°C (216°F)

-

250

50

2 A

BEAB, CCC, CSA, PSE, UL, VDE

200°C (392°F)

N

Obsolete

Bulk

Fuse

65°C (149°F)

92°C (198°F)

-

250

50

2 A

PSE, UL

200°C (392°F)

N

Obsolete

Bulk

Fuse

60°C (140°F)

86°C (187°F)

-

250

50

2 A

BEAB, CCC, CSA, PSE, UL, VDE

200°C (392°F)

H

Obsolete

Bulk

Fuse

125°C (257°F)

145°C (293°F)

-

250

50

500 mA

BEAB, CCC, CSA, PSE, UL, VDE

200°C (392°F)

H

Obsolete

Box

Fuse

105°C (221°F)

139°C (282°F)

-

250

50

-

BEAB, CCC, CSA,cUL, PSE, UL, VDE

200°C (392°F)

H

Obsolete

Box

Fuse

95°C (203°F)

134°C (273°F)

-

250

50

-

BEAB, CCC, CSA,cUL, PSE, UL, VDE

200°C (392°F)

H

Obsolete

Box

Fuse

90°C (194°F)

115°C (239°F)

-

250

50

-

BEAB, CCC, CSA,cUL, PSE, UL, VDE

200°C (392°F)

F

Obsolete

Bulk

Fuse

142°C (288°F)

168°C (334°F)

-

250

50

1 A

BEAB, CCC, CSA, PSE, UL, VDE

200°C (392°F)

F

Obsolete

Box

Fuse

125°C (257°F)

145°C (293°F)

-

250

50

-

BEAB, CCC, CSA,cUL, PSE, UL, VDE

200°C (392°F)

F

Obsolete

Bulk

Fuse

115°C (239°F)

139°C (282°F)

-

250

50

1 A

BEAB, CCC, CSA, PSE, UL, VDE

200°C (392°F)

F

Obsolete

Box

Fuse

110°C (230°F)

139°C (282°F)

-

250

50

-

BEAB, CCC, CSA,cUL, PSE, UL, VDE

200°C (392°F)

F

Obsolete

Box

Fuse

105°C (221°F)

134°C (273°F)

-

250

50

-

BEAB, CCC, CSA,cUL, PSE, UL, VDE

200°C (392°F)

F

Obsolete

Bulk

Fuse

108°C (226°F)

133°C (271°F)

-

250

50

1 A

BEAB, CCC, CSA, PSE, UL, VDE

200°C (392°F)

F

Obsolete

Bulk

Fuse

105°C (221°F)

130°C (266°F)

-

250

50

1 A

BEAB, CCC, CSA, PSE, UL, VDE

200°C (392°F)

F

Obsolete

Bulk

Fuse

90°C (194°F)

115°C (239°F)

-

250

50

1 A

BEAB, CCC, CSA, PSE, UL, VDE

200°C (392°F)

F

Obsolete

Bulk

Fuse

76°C (169°F)

102°C (216°F)

-

250

50

1 A

BEAB, CCC, CSA, PSE, UL, VDE

200°C (392°F)

F

Obsolete

Box

Fuse

75°C (167°F)

102°C (216°F)

-

250

50

-

BEAB, CCC, CSA,cUL, PSE, UL, VDE

200°C (392°F)

E

Obsolete

Box

Fuse

125°C (257°F)

145°C (293°F)

-

250

50

-

BEAB, CCC, CSA,cUL, PSE, UL, VDE

200°C (392°F)

E

Obsolete

Bulk

Fuse

120°C (248°F)

139°C (282°F)

-

250

50

500 mA

BEAB, CCC, CSA, PSE, UL, VDE

200°C (392°F)

E

Obsolete

Box

Fuse

115°C (239°F)

139°C (282°F)

-

250

50

-

BEAB, CCC, CSA,cUL, PSE, UL, VDE

200°C (392°F)

E

Obsolete

Bulk

Fuse

105°C (221°F)

134°C (273°F)

-

250

50

500 mA

BEAB, CCC, CSA, PSE, UL, VDE

200°C (392°F)

E

Obsolete

Bulk

Fuse

115°C (239°F)

133°C (271°F)

-

250

50

500 mA

BEAB, CCC, CSA, PSE, UL, VDE

200°C (392°F)

E

Obsolete

Bulk

Fuse

112°C (234°F)

130°C (266°F)

-

250

50

500 mA

BEAB, CCC, CSA, PSE, UL, VDE

200°C (392°F)

E

Obsolete

Bulk

Fuse

95°C (203°F)

115°C (239°F)

-

250

50

500 mA

BEAB, CCC, CSA, PSE, UL, VDE

200°C (392°F)

E

Obsolete

Bulk

Fuse

80°C (176°F)

102°C (216°F)

-

250

50

500 mA

BEAB, CCC, CSA, PSE, UL, VDE

200°C (392°F)

E

Obsolete

Box

Fuse

75°C (167°F)

102°C (216°F)

-

250

50

-

BEAB, CCC, CSA,cUL, PSE, UL, VDE

200°C (392°F)

E

Obsolete

Bulk

Fuse

75°C (167°F)

102°C (216°F)

-

250

50

500 mA

BEAB, CCC, CSA, PSE, UL, VDE

200°C (392°F)

-

Active

Bulk

Fuse

-

139°C (282°F)

-

250

-

-

CCC, UL/cUL, VDE

-

CB

Active

Bag

Breaker

25°C (77°F)

85°C (185°F)

40°C (104°F)

-

28

25 A

cUL, TUV, UL

-

CB

Active

Bag

Breaker

25°C (77°F)

85°C (185°F)

40°C (104°F)

-

28

25 A

cUL, TUV, UL

-

CB

Active

Bag

Breaker

25°C (77°F)

82°C (180°F)

40°C (104°F)

-

28

25 A

cUL, TUV, UL

-

CB

Active

Bag

Breaker

25°C (77°F)

82°C (180°F)

40°C (104°F)

-

28

25 A

cUL, TUV, UL

-

CB

Active

Bag

Breaker

25°C (77°F)

77°C (171°F)

40°C (104°F)

-

28

25 A

cUL, TUV, UL

-

CB

Active

Bag

Breaker

25°C (77°F)

77°C (171°F)

40°C (104°F)

-

28

25 A

cUL, TUV, UL

-

CB

Active

Bag

Breaker

25°C (77°F)

72°C (162°F)

40°C (104°F)

-

28

25 A

cUL, TUV, UL

-

CB

Discontinued at Digi-Key

Bag

Breaker

25°C (77°F)

72°C (162°F)

40°C (104°F)

-

28

25 A

cUL, TUV, UL

-

C

Active

Bulk

Fuse

89°C (192°F)

115°C (239°F)

-

250

60

7 A

CCC, cUL, KTL, PSE, TUV, UL

200°C (392°F)

C

Active

Bulk

Fuse

61°C (142°F)

86°C (187°F)

-

250

60

6 A

CCC, KTL, PSE, TUV

200°C (392°F)

C

Active

Bulk

Fuse

77°C (171°F)

102°C (216°F)

-

250

50

5 A

CCC, KTL, PSE, TUV

200°C (392°F)

B

Active

Bulk

Fuse

91°C (196°F)

115°C (239°F)

-

250

50

3 A

CCC, cUL, KTL, PSE, TUV, UL

200°C (392°F)

B

Active

Bulk

Fuse

61°C (142°F)

86°C (187°F)

-

250

50

3 A

CCC, KTL, PSE, TUV

200°C (392°F)

B

Active

Bulk

Fuse

79°C (174°F)

102°C (216°F)

-

250

50

3 A

CCC, KTL, PSE, TUV

200°C (392°F)

A5MC

Active

Box

Fuse

-

139°C (282°F)

-

250

-

-

CCC, cUL, KC, UL, VDE

-

AC

Active

Bag

Breaker

-

90°C (194°F)

40°C (104°F)

-

28

35 A

cUL, TUV, UL

-

AC

Active

Bag

Breaker

-

85°C (185°F)

40°C (104°F)

-

28

35 A

cUL, TUV, UL

-

AC

Active

Bag

Breaker

-

82°C (180°F)

40°C (104°F)

-

28

35 A

cUL, TUV, UL

-

AC

Active

Bag

Breaker

-

77°C (171°F)

40°C (104°F)

-

28

35 A

cUL, TUV, UL

-

AC

Active

Bag

Breaker

-

72°C (162°F)

40°C (104°F)

-

28

35 A

cUL, TUV, UL

-

Komatsuliteu2122, AA

Active

Bag

Breaker

-

85°C (185°F)

40°C (104°F)

-

28

35 A

cUL, TUV, UL

-

Komatsuliteu2122, AA

Active

Bag

Breaker

-

85°C (185°F)

40°C (104°F)

-

28

35 A

cUL, TUV, UL

-

Komatsuliteu2122, AA

Active

Bag

Breaker

-

82°C (180°F)

40°C (104°F)

-

28

35 A

cUL, TUV, UL

-

Komatsuliteu2122, AA

Active

Bag

Breaker

-

82°C (180°F)

40°C (104°F)

-

28

35 A

cUL, TUV, UL

-

Komatsuliteu2122, AA

Active

Bag

Breaker

-

77°C (171°F)

40°C (104°F)

-

28

35 A

cUL, TUV, UL

-

Komatsuliteu2122, AA

Active

Bag

Breaker

-

77°C (171°F)

40°C (104°F)

-

28

35 A

cUL, TUV, UL

-

Komatsuliteu2122, AA

Active

Bag

Breaker

-

72°C (162°F)

40°C (104°F)

-

28

35 A

cUL, TUV, UL

-

Komatsuliteu2122, AA

Active

Bag

Breaker

-

72°C (162°F)

40°C (104°F)

-

28

35 A

cUL, TUV, UL

-

-

Active

-

-

-

-

-

-

-

-

-

-

RTS

Active

Tape & Reel (TR) Cut Tape (CT) Digi-Reel®

Fuse

-

-

-

-

60

-

UL

-

RTS

Active

Tape & Reel (TR) Cut Tape (CT) Digi-Reel®

Fuse

-

-

-

-

60

-

UL

-

Contact Us

Compaq Electronics Asia Limited

Tel.: +886-15986828728

Email: info@compaqelectronics.com

Add.: Room 504, Unit 2, Building 8, Huilongyuan, Minzhi Street, Longhua New District, Shenzhen

UPLOAD B.O.M

Follow Us

Copyright © Compaq Electronics Asia Limited All Rights Reserved | Sitemap

WeChat