ZH
|
Active
|
Tray
|
Solenoid Release
|
DPST-NO/NC
|
5A (DC)
|
24VDC
|
-
|
179kgf
|
Panel Disconnect
|
Screw Terminal
|
Manual Unlocking by Triangular Key
|
-
|
-
|
M20 x2
|
IP67 - Dust Tight, Waterproof
|
CE
|
|
|
|
ZH
|
Active
|
Tray
|
Solenoid Locking
|
DPST-NO/NC
|
5A (DC)
|
24VDC
|
-
|
179kgf
|
Panel Disconnect
|
Screw Terminal
|
Manual Unlocking by Triangular Key
|
-
|
-
|
M20 x2
|
IP67 - Dust Tight, Waterproof
|
CE
|
|
|
|
ZH
|
Active
|
Tray
|
Solenoid Release
|
3PST-2NC/1NO
|
2.5A (DC)
|
24VDC
|
-
|
255kgf
|
Panel Disconnect
|
Screw Terminal
|
Manual Unlocking by Triangular Key
|
-
|
-
|
M16 x4
|
IP67 - Dust Tight, Waterproof
|
CE
|
|
|
|
ZH
|
Active
|
Tray
|
Solenoid Locking
|
3PST-2NO/1NC
|
2.5A (DC)
|
24VDC
|
-
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
Manual Unlocking by Triangular Key
|
-
|
-
|
M16 x4
|
IP67 - Dust Tight, Waterproof
|
CE
|
|
|
|
XCSTR
|
Active
|
Box
|
Non-Locking
|
3PST-NC
|
6A (AC), 200mA (DC)
|
120VAC, 125VDC
|
-
|
-
|
Shaft
|
Screw Terminal
|
-
|
-
|
-
|
1/2" NPT
|
IP67 - Dust Tight, Waterproof
|
BG, CSA, UL
|
|
|
|
XCST
|
Active
|
Box
|
Solenoid Locking
|
DPST-NC
|
3A (AC), 550mA (DC)
|
120VAC, 125VDC
|
-
|
-
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M16 x 1.5
|
IP67 - Dust Tight, Waterproof
|
CSA, UL
|
|
|
|
XCSTE
|
Active
|
Box
|
Solenoid Locking
|
DPST-NC
|
6A (AC)
|
120VAC
|
-
|
-
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
-
|
IP67 - Dust Tight, Waterproof
|
-
|
|
|
|
XCSTE
|
Active
|
Box
|
Solenoid Locking
|
DPST-NC
|
3A (AC)
|
120VAC, 125VDC
|
-
|
51kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
1/2" NPT
|
IP67 - Dust Tight, Waterproof
|
CSA, UL
|
|
|
|
XCSTE
|
Active
|
Box
|
Solenoid Locking
|
DPST-NC
|
3A (AC), 550mA (DC)
|
120VAC, 125VDC
|
-
|
-
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M16 x 1.5
|
IP67 - Dust Tight, Waterproof
|
CSA, UL
|
|
|
|
XCSTE
|
Active
|
Box
|
Solenoid Locking
|
DPST-NO/NC
|
3A (AC)
|
120VAC, 125VDC
|
-
|
1.5kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
PG11
|
IP67 - Dust Tight, Waterproof
|
CSA, UL
|
|
|
|
XCST
|
Active
|
Box
|
Solenoid Locking
|
DPST-NO/NC
|
6A (AC)
|
24VAC
|
-
|
-
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
-
|
IP67 - Dust Tight, Waterproof
|
-
|
|
|
|
XCSTE
|
Active
|
Box
|
Solenoid Locking
|
DPST-NO/NC
|
3A (AC), 550mA (DC)
|
120VAC, 125VDC
|
-
|
-
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
1/2" NPT
|
IP67 - Dust Tight, Waterproof
|
CSA, UL
|
|
|
|
XCSTE
|
Active
|
Box
|
Solenoid Locking
|
DPST-NO/NC
|
3A (AC)
|
120VAC, 125VDC
|
-
|
51kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M16 x 1.5
|
IP66/IP67 - Dust Tight, Water Resistant, Waterproof
|
CSA, UL
|
|
|
|
XCSTE
|
Active
|
Box
|
Solenoid Locking
|
DPST-NO/NC
|
3A (AC)
|
120VAC, 125VDC
|
-
|
1.5kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
PG11
|
IP67 - Dust Tight, Waterproof
|
CSA, UL
|
|
|
|
XCST
|
Active
|
Box
|
Non-Locking
|
3PST-NC
|
6A (AC), 550mA (DC)
|
120VAC, 125VDC
|
-
|
-
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
1/2" NPT
|
IP67 - Dust Tight, Waterproof
|
CSA, UL
|
|
|
|
XCST
|
Active
|
Box
|
Non-Locking
|
3PST-1NO/2NC
|
6A (AC), 550mA (DC)
|
120VAC, 125VDC
|
-
|
-
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
1/2" NPT
|
IP67 - Dust Tight, Waterproof
|
CSA, UL
|
|
|
|
XCSTA
|
Active
|
Box
|
Non-Locking
|
3PST-1NO/2NC
|
6A (AC), 550mA (DC)
|
120VAC, 125VDC
|
-
|
-
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
PG11
|
IP67 - Dust Tight, Waterproof
|
CSA, UL
|
|
|
|
XCSTA
|
Active
|
Box
|
Non-Locking
|
3PST-2NO/1NC
|
6A (AC), 550mA (DC)
|
120VAC, 125VDC
|
-
|
-
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
1/2" NPT
|
IP67 - Dust Tight, Waterproof
|
CSA, UL
|
|
|
|
XCSRC
|
Active
|
Box
|
RFID
|
-
|
60mA (DC)
|
24VDC
|
-
|
-
|
Non-Contact
|
Connector (M12)
|
-
|
10mm
|
35mm
|
-
|
IP65/IP66/IP67/IP69K - Dust Tight, Water Resistant, Waterproof
|
CSA, E2, EAC, Ecolab, FCC, IC, RCM, TUV
|
|
|
|
XCSRC
|
Active
|
Box
|
RFID
|
-
|
60mA (DC)
|
24VDC
|
-
|
-
|
Non-Contact
|
Connector (M12)
|
-
|
10mm
|
35mm
|
-
|
IP65/IP66/IP67/IP69K - Dust Tight, Water Resistant, Waterproof
|
CSA, E2, EAC, FCC, IC, RCM, TUV
|
|
|
|
XCSRC
|
Active
|
Box
|
RFID
|
-
|
60mA (DC)
|
24VDC
|
-
|
-
|
Non-Contact
|
Connector (M12)
|
-
|
10mm
|
35mm
|
-
|
IP65/IP66/IP67/IP69K - Dust Tight, Water Resistant, Waterproof
|
CSA, E2, EAC, Ecolab, FCC, IC, RCM, TUV
|
|
|
|
XCSRC
|
Active
|
Box
|
RFID
|
-
|
60mA (DC)
|
24VDC
|
-
|
-
|
Non-Contact
|
Connector (M12)
|
-
|
10mm
|
35mm
|
-
|
IP65/IP66/IP67/IP69K - Dust Tight, Water Resistant, Waterproof
|
CSA, E2, EAC, Ecolab, FCC, IC, RCM, TUV
|
|
|
|
XCSP
|
Active
|
Box
|
Non-Locking
|
DPST-NO/NC
|
6A (AC), 550mA (DC)
|
120VAC, 125VDC
|
-
|
-
|
Shaft
|
Screw Terminal
|
-
|
-
|
-
|
1/2" NPT
|
IP67 - Dust Tight, Waterproof
|
CSA, UL
|
|
|
|
XCSPL
|
Active
|
Box
|
Non-Locking
|
DPST-NO/NC
|
6A (AC), 550mA (DC)
|
120VAC, 125VDC
|
-
|
-
|
Arm Lever
|
Screw Terminal
|
-
|
-
|
-
|
PG11
|
IP67 - Dust Tight, Waterproof
|
BG, CSA, UL
|
|
|
|
XCSPL
|
Active
|
Box
|
Non-Locking
|
DPST-NO/NC
|
6A (AC), 550mA (DC)
|
120VAC, 125VDC
|
-
|
-
|
Arm Lever
|
Screw Terminal
|
-
|
-
|
-
|
1/2" NPT
|
IP67 - Dust Tight, Waterproof
|
BG, CSA, UL
|
|
|
|
XCSPA
|
Active
|
Box
|
Non-Locking
|
DPST-NC
|
6A (AC)
|
120VAC, 125VDC
|
-
|
1kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
1/2" NPT
|
IP67 - Dust Tight, Waterproof
|
CSA, UL
|
|
|
|
XCSPA
|
Active
|
Box
|
Non-Locking
|
DPST-NC
|
6A (AC), 550mA (DC)
|
120VAC, 125VDC
|
-
|
-
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M16 x 1.5
|
IP67 - Dust Tight, Waterproof
|
CSA, UL
|
|
|
|
XCSP
|
Active
|
Box
|
Non-Locking
|
DPST-NC
|
6A (AC), 550mA (DC)
|
120VAC, 125VDC
|
-
|
-
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
PG11
|
IP67 - Dust Tight, Waterproof
|
CSA, UL
|
|
|
|
XCSPA
|
Active
|
Box
|
Non-Locking
|
DPST-NO/NC
|
6A (AC), 550mA (DC)
|
120VAC, 125VDC
|
-
|
-
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M16 x 1.5
|
IP67 - Dust Tight, Waterproof
|
CSA, UL
|
|
|
|
XCSPA
|
Active
|
Box
|
Non-Locking
|
DPST-NO/NC
|
6A (AC)
|
120VAC, 125VDC
|
-
|
1kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
1/2" NPT
|
IP67 - Dust Tight, Waterproof
|
CSA, UL
|
|
|
|
XCSPA
|
Active
|
Box
|
Non-Locking
|
DPST-NO/NC
|
6A (AC)
|
120VAC, 125VDC
|
-
|
1kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M16 x 1.5
|
IP67 - Dust Tight, Waterproof
|
CSA, UL
|
|
|
|
XCSP
|
Active
|
Box
|
Non-Locking
|
DPST-NO/NC
|
6A (AC), 550mA (DC)
|
120VAC, 125VDC
|
-
|
-
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
PG11
|
IP67 - Dust Tight, Waterproof
|
CSA, UL
|
|
|
|
XCSMP
|
Active
|
Box
|
Non-Locking
|
DPST-NC
|
1.5A (AC), 550mA (DC)
|
120VAC, 125VDC
|
-
|
816gf
|
Panel Disconnect
|
Cable Leads
|
-
|
-
|
-
|
-
|
IP67 - Dust Tight, Waterproof
|
CSA, CUL, UL
|
|
|
|
XCSMP
|
Active
|
Box
|
Non-Locking
|
3PST-1NO/2NC
|
1.5A (AC), 550mA (DC)
|
120VAC, 125VDC
|
-
|
816gf
|
Panel Disconnect
|
Cable Leads
|
-
|
-
|
-
|
-
|
IP67 - Dust Tight, Waterproof
|
CSA, CUL, UL
|
|
|
|
XCSLF
|
Active
|
Box
|
Solenoid Locking
|
3PST-1NO/2NC
|
750mA (AC), 550mA (DC)
|
240VAC, 24VDC
|
-
|
306kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
1/2" NPT
|
IP66/IP67 - Dust Tight, Water Resistant, Waterproof
|
CSA, TUV, UL
|
|
|
|
XCSLF
|
Active
|
Box
|
Solenoid Locking
|
3PST-1NO/2NC
|
750mA (AC), 550mA (DC)
|
240VAC, 24VDC
|
-
|
306kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
1/2" NPT
|
IP66 - Dust Tight, Waterproof
|
CSA, TUV, UL
|
|
|
|
XCSLF
|
Active
|
Box
|
Solenoid Locking
|
3PST-1NO/2NC
|
750mA (AC), 550mA (DC)
|
240VAC, 24VDC
|
-
|
306kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
1/2" NPT
|
IP66/IP67 - Dust Tight, Water Resistant, Waterproof
|
CSA, TUV, UL
|
|
|
|
XCSLF
|
Active
|
Box
|
Solenoid Locking
|
3PST-1NO/2NC
|
750mA (AC), 550mA (DC)
|
240VAC, 24VDC
|
-
|
306kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
1/2" NPT
|
IP66/IP67 - Dust Tight, Water Resistant, Waterproof
|
CSA, TUV, UL
|
|
|
|
XCSLF
|
Active
|
Box
|
Solenoid Locking
|
3PST-1NO/2NC
|
750mA (AC), 550mA (DC)
|
240VAC, 24VDC
|
-
|
306kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x 1.5
|
IP66/IP67 - Dust Tight, Water Resistant, Waterproof
|
CSA, TUV, UL
|
|
|
|
XCSLF
|
Active
|
Box
|
Solenoid Locking
|
DPST-NC
|
750mA (AC), 550mA (DC)
|
240VAC, 24VDC
|
-
|
306kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
1/2" NPT
|
IP66/IP67 - Dust Tight, Water Resistant, Waterproof
|
CSA, TUV, UL
|
|
|
|
XCSLE
|
Active
|
Box
|
Solenoid Locking
|
3PST-1NO/2NC
|
750mA (AC), 550mA (DC)
|
240VAC, 24VDC
|
-
|
143kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x 1.5
|
IP66/IP67 - Dust Tight, Water Resistant, Waterproof
|
CSA, TUV, UL
|
|
|
|
XCSLE
|
Active
|
Box
|
Solenoid Locking
|
DPST-NC
|
750mA (AC), 550mA (DC)
|
240VAC, 24VDC
|
-
|
143kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x 1.5
|
IP66/IP67 - Dust Tight, Water Resistant, Waterproof
|
CSA, TUV, UL
|
|
|
|
XCSLE
|
Active
|
Box
|
Solenoid Locking
|
DPST-NC
|
750mA (AC), 550mA (DC)
|
240VAC, 24VDC
|
-
|
143kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
1/2" NPT
|
IP66/IP67 - Dust Tight, Water Resistant, Waterproof
|
CSA, TUV, UL
|
|
|
|
XCSL
|
Active
|
Box
|
Non-Locking
|
-
|
-
|
-
|
-
|
-
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
-
|
-
|
-
|
|
|
|
XCSL
|
Active
|
Box
|
Key Locking
|
-
|
-
|
-
|
-
|
-
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
-
|
-
|
-
|
|
|
|
XCSL
|
Active
|
Box
|
Key Locking
|
3PST-1NO/2NC
|
10A (DC)
|
24VDC
|
-
|
-
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
-
|
IP67 - Dust Tight, Waterproof
|
-
|
|
|
|
XCSL
|
Active
|
Box
|
Key Locking
|
3PST-1NO/2NC
|
10A (AC)
|
110VAC
|
-
|
-
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
-
|
IP67 - Dust Tight, Waterproof
|
-
|
|
|
|
XCSL
|
Active
|
Box
|
Key Locking
|
3PST-1NO/2NC
|
10A (DC)
|
24VDC
|
-
|
-
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
-
|
IP67 - Dust Tight, Waterproof
|
-
|
|
|
|
XCSE
|
Active
|
Box
|
Solenoid Locking
|
3PST-NC
|
3A (AC), 550mA (DC)
|
120VAC, 125VDC
|
-
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
PG13.5
|
IP67 - Dust Tight, Waterproof
|
CSA, UL
|
|
|
|
XCSE
|
Active
|
Box
|
Solenoid Locking
|
3PST-1NO/2NC
|
3A (AC), 550mA (DC)
|
120VAC, 125VDC
|
-
|
2kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
1/2" NPT
|
IP67 - Dust Tight, Waterproof
|
CSA, UL
|
|
|
|
XCSE
|
Active
|
Box
|
Solenoid Locking
|
3PST-1NO/2NC
|
3A (AC), 550mA (DC)
|
120VAC, 125VDC
|
-
|
2kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
1/2" NPT
|
IP67 - Dust Tight, Waterproof
|
CSA, UL
|
|
|
|
XCSE
|
Active
|
Box
|
Solenoid Locking
|
3PST-1NO/2NC
|
3A (AC), 550mA (DC)
|
120VAC, 125VDC
|
-
|
2kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
PG13.5
|
IP67 - Dust Tight, Waterproof
|
CSA, UL
|
|
|
|
XCSE
|
Active
|
Box
|
Solenoid Locking
|
3PST-1NO/2NC
|
3A (AC), 550mA (DC)
|
120VAC, 125VDC
|
-
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x 1.5
|
IP67 - Dust Tight, Waterproof
|
CSA, UL
|
|
|
|
XCSE
|
Active
|
Box
|
Solenoid Locking
|
3PST-1NO/2NC
|
3A (AC), 550mA (DC)
|
120VAC, 125VDC
|
-
|
2kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
1/2" NPT
|
IP67 - Dust Tight, Waterproof
|
CSA, UL
|
|
|
|
XCSE
|
Active
|
Box
|
Solenoid Locking
|
3PST-1NO/2NC
|
3A (AC), 550mA (DC)
|
120VAC, 125VDC
|
-
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
1/2" NPT
|
IP67 - Dust Tight, Waterproof
|
CSA, UL
|
|
|
|
XCSE
|
Active
|
Box
|
Solenoid Locking
|
3PST-1NO/2NC
|
3A (AC), 550mA (DC)
|
120VAC, 125VDC
|
-
|
2kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
1/2" NPT
|
IP67 - Dust Tight, Waterproof
|
CSA, UL
|
|
|
|
XCSE
|
Active
|
Box
|
Solenoid Locking
|
3PST-1NO/2NC
|
3A (AC), 550mA (DC)
|
120VAC, 125VDC
|
-
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x 1.5
|
IP67 - Dust Tight, Waterproof
|
CSA, UL
|
|
|
|
XCSE
|
Active
|
Box
|
Solenoid Locking
|
3PST-1NO/2NC
|
3A (AC), 550mA (DC)
|
120VAC, 125VDC
|
-
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
PG13.5
|
IP67 - Dust Tight, Waterproof
|
CSA, UL
|
|
|
|
XCSE
|
Active
|
Box
|
Solenoid Locking
|
3PST-1NO/2NC
|
3A (AC), 550mA (DC)
|
120VAC, 125VDC
|
-
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
PG13.5
|
IP67 - Dust Tight, Waterproof
|
CSA, UL
|
|
|
|
XCSE
|
Active
|
Box
|
Solenoid Locking
|
3PST-1NO/2NC
|
3A (AC), 550mA (DC)
|
120VAC, 125VDC
|
-
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
PG13.5
|
IP67 - Dust Tight, Waterproof
|
CSA, UL
|
|
|
|
XCSE
|
Active
|
Box
|
Solenoid Locking
|
3PST-1NO/2NC
|
3A (AC), 550mA (DC)
|
120VAC, 125VDC
|
-
|
2kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
PG13.5
|
IP67 - Dust Tight, Waterproof
|
CSA, UL
|
|
|
|
XCSE
|
Active
|
Box
|
Solenoid Locking
|
3PST-2NO/1NC
|
3A (AC), 550mA (DC)
|
120VAC, 125VDC
|
-
|
2kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
1/2" NPT
|
IP67 - Dust Tight, Waterproof
|
CSA, UL
|
|
|
|
XCSE
|
Active
|
Box
|
Solenoid Locking
|
3PST-2NO/1NC
|
3A (AC), 550mA (DC)
|
120VAC, 125VDC
|
-
|
2kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
1/2" NPT
|
IP67 - Dust Tight, Waterproof
|
CSA, UL
|
|
|
|
XCSE
|
Active
|
Box
|
Solenoid Locking
|
3PST-2NO/1NC
|
3A (AC), 550mA (DC)
|
120VAC, 125VDC
|
-
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
PG13.5
|
IP67 - Dust Tight, Waterproof
|
CSA, UL
|
|
|
|
XCSE
|
Active
|
Box
|
Solenoid Locking
|
3PST-2NO/1NC
|
3A (AC), 550mA (DC)
|
120VAC, 125VDC
|
-
|
2kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
PG13.5
|
IP67 - Dust Tight, Waterproof
|
CSA, UL
|
|
|
|
XCSDMR
|
Active
|
Box
|
Magnetic
|
DPST-NC
|
100mA (DC)
|
24VDC
|
-
|
-
|
-
|
Cable with Connector (M12)
|
-
|
8mm
|
20mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CSA, UL
|
|
|
|
XCSDMR
|
Active
|
Box
|
Magnetic
|
DPST-NC
|
100mA (DC)
|
24VDC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
8mm
|
20mm
|
-
|
IP66/IP67 - Dust Tight, Water Resistant, Waterproof
|
CSA, UL
|
|
|
|
XCSDMR
|
Active
|
Box
|
Magnetic
|
DPST-NC
|
100mA (DC)
|
24VDC
|
-
|
-
|
-
|
Cable with Connector (M12)
|
-
|
8mm
|
20mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CSA, UL
|
|
|
|
XCSDMR
|
Active
|
Box
|
Magnetic
|
DPST-NC
|
100mA (DC)
|
24VDC
|
-
|
-
|
-
|
Cable Leads
|
-
|
8mm
|
20mm
|
-
|
IP66/IP67 - Dust Tight, Water Resistant, Waterproof
|
CSA, UL
|
|
|
|
XCSD
|
Active
|
Box
|
Magnetic
|
DPST-NO/NC
|
100mA (DC)
|
24VDC
|
-
|
-
|
-
|
Cable Leads
|
-
|
8mm
|
20mm
|
-
|
IP66/IP67 - Dust Tight, Water Resistant, Waterproof
|
CSA, UL
|
|
|
|
XCSDMR
|
Active
|
Box
|
Magnetic
|
DPST-NO/NC
|
100mA (DC)
|
24VDC
|
-
|
-
|
-
|
Cable Leads
|
-
|
8mm
|
20mm
|
-
|
IP66/IP67 - Dust Tight, Water Resistant, Waterproof
|
CSA, UL
|
|
|
|
XCSDMR
|
Active
|
Box
|
Magnetic
|
DPST-NO/NC
|
100mA (DC)
|
24VDC
|
-
|
-
|
-
|
Cable Leads
|
-
|
8mm
|
20mm
|
-
|
IP66/IP67 - Dust Tight, Water Resistant, Waterproof
|
CSA, UL
|
|
|
|
XCSDMP
|
Active
|
Box
|
Magnetic
|
DPST-NC
|
100mA (DC)
|
24VDC
|
-
|
-
|
Non-Contact
|
Cable with Connector (M12)
|
-
|
8mm
|
20mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CSA, UL
|
|
|
|
XCSDMP
|
Active
|
Box
|
Magnetic
|
DPST-NC
|
100mA (DC)
|
24VDC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
8mm
|
20mm
|
-
|
IP66/IP67 - Dust Tight, Water Resistant, Waterproof
|
CSA, UL
|
|
|
|
XCSDMP
|
Active
|
Box
|
Magnetic
|
3PST-1NO/2NC
|
100mA (DC)
|
24VDC
|
-
|
-
|
Non-Contact
|
Cable with Connector (M12)
|
-
|
8mm
|
20mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CSA, UL
|
|
|
|
XCSDMP
|
Active
|
Box
|
Magnetic
|
3PST-1NO/2NC
|
100mA (DC)
|
24VDC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
8mm
|
20mm
|
-
|
IP66/IP67 - Dust Tight, Water Resistant, Waterproof
|
CSA, UL
|
|
|
|
XCSDMP
|
Active
|
Box
|
Magnetic
|
3PST-2NO/1NC
|
100mA (DC)
|
24VDC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
8mm
|
20mm
|
-
|
IP66/IP67 - Dust Tight, Water Resistant, Waterproof
|
CSA, UL
|
|
|
|
XCSDMP
|
Active
|
Box
|
Magnetic
|
3PST-2NC/1NO
|
100mA (DC)
|
24VDC
|
-
|
-
|
Non-Contact
|
Connector (M12)
|
-
|
-
|
-
|
-
|
IP67 - Dust Tight, Waterproof
|
CSA, UL
|
|
|
|
XCSDMP
|
Active
|
Box
|
Magnetic
|
3PST-1NO/2NC
|
100mA (DC)
|
24VDC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
8mm
|
20mm
|
-
|
IP66/IP67 - Dust Tight, Water Resistant, Waterproof
|
CSA, UL
|
|
|
|
XCSDMP
|
Active
|
Box
|
Magnetic
|
3PST-2NC/1NO
|
100mA (DC)
|
24VDC
|
-
|
-
|
Non-Contact
|
Connector (M12)
|
-
|
-
|
-
|
-
|
IP66/IP67 - Dust Tight, Water Resistant, Waterproof
|
CSA, UL
|
|
|
|
XCSDMP
|
Active
|
Box
|
Magnetic
|
3PST-2NC/1NO
|
100mA (DC)
|
24VDC
|
-
|
-
|
Non-Contact
|
Connector (M12)
|
-
|
-
|
-
|
-
|
IP66/IP67 - Dust Tight, Water Resistant, Waterproof
|
CSA, UL
|
|
|
|
XCSDMP
|
Active
|
Box
|
Magnetic
|
DPST-NO/NC
|
100mA (DC)
|
24VDC
|
-
|
-
|
Non-Contact
|
Cable with Connector (M12)
|
-
|
8mm
|
20mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CSA, UL
|
|
|
|
XCSDMP
|
Active
|
Box
|
Magnetic
|
DPST-NO/NC
|
100mA (DC)
|
24VDC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
8mm
|
20mm
|
-
|
IP66/IP67 - Dust Tight, Water Resistant, Waterproof
|
CSA, UL
|
|
|
|
XCSDMP
|
Active
|
Box
|
Magnetic
|
3PST-2NO/1NC
|
100mA (DC)
|
24VDC
|
-
|
-
|
Non-Contact
|
Cable with Connector (M12)
|
-
|
8mm
|
20mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CSA, UL
|
|
|
|
XCSDMP
|
Active
|
Box
|
Magnetic
|
3PST-2NO/1NC
|
100mA (DC)
|
24VDC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
8mm
|
20mm
|
-
|
IP66/IP67 - Dust Tight, Water Resistant, Waterproof
|
CSA, UL
|
|
|
|
XCSDMP
|
Active
|
Box
|
Magnetic
|
3PST-2NO/1NC
|
100mA (DC)
|
24VDC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
8mm
|
20mm
|
-
|
IP66/IP67 - Dust Tight, Water Resistant, Waterproof
|
CSA, UL
|
|
|
|
XCSDMP
|
Active
|
Box
|
Magnetic
|
3PST-2NO/1NC
|
100mA (DC)
|
24VDC
|
-
|
-
|
Non-Contact
|
Cable with Connector (M12)
|
-
|
8mm
|
20mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CSA, UL
|
|
|
|
XCSDMP
|
Active
|
Box
|
Magnetic
|
3PST-2NO/1NC
|
100mA (DC)
|
24VDC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
8mm
|
20mm
|
-
|
IP66/IP67 - Dust Tight, Water Resistant, Waterproof
|
CSA, UL
|
|
|
|
XCSDMP
|
Active
|
Box
|
Magnetic
|
3PST-2NO/1NC
|
100mA (DC)
|
24VDC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
8mm
|
20mm
|
-
|
IP66/IP67 - Dust Tight, Water Resistant, Waterproof
|
CSA, UL
|
|
|
|
XCSDMC
|
Active
|
Box
|
Magnetic
|
DPST-NC
|
100mA (DC)
|
24VDC
|
-
|
-
|
Non-Contact
|
Cable with Connector (M8)
|
-
|
5mm
|
15mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CSA, UL
|
|
|
|
XCSDMC
|
Active
|
Box
|
Magnetic
|
DPST-NC
|
100mA (DC)
|
24VDC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
5mm
|
15mm
|
-
|
IP66/IP67 - Dust Tight, Water Resistant, Waterproof
|
CSA, UL
|
|
|
|
XCSDMC
|
Active
|
Box
|
Magnetic
|
DPST-NC
|
100mA (DC)
|
24VDC
|
-
|
-
|
Non-Contact
|
Cable with Connector (M8)
|
-
|
5mm
|
15mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CSA, UL
|
|
|
|
XCSDMC
|
Active
|
Box
|
Magnetic
|
DPST-NC
|
100mA (DC)
|
24VDC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
5mm
|
15mm
|
-
|
IP66/IP67 - Dust Tight, Water Resistant, Waterproof
|
CSA, UL
|
|
|
|
XCSD
|
Active
|
Box
|
Magnetic
|
DPST-NC
|
100mA (DC)
|
24VDC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
5mm
|
15mm
|
-
|
IP66/IP67 - Dust Tight, Water Resistant, Waterproof
|
CSA, UL
|
|
|
|
XCSDMC
|
Active
|
Box
|
Magnetic
|
DPST-NC
|
100mA (DC)
|
24VDC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
5mm
|
15mm
|
-
|
IP66/IP67 - Dust Tight, Water Resistant, Waterproof
|
CSA, UL
|
|
|
|
XCSDMC
|
Active
|
Box
|
Magnetic
|
DPST-NO/NC
|
100mA (DC)
|
24VDC
|
-
|
-
|
Non-Contact
|
Cable with Connector (M8)
|
-
|
5mm
|
15mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CSA, UL
|
|
|
|
XCSDMC
|
Active
|
Box
|
Magnetic
|
DPST-NO/NC
|
100mA (DC)
|
24VDC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
5mm
|
15mm
|
-
|
IP66/IP67 - Dust Tight, Water Resistant, Waterproof
|
CSA, UL
|
|
|
|
XCSD
|
Active
|
Box
|
Magnetic
|
DPST-NO/NC
|
100mA (DC)
|
24VDC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
5mm
|
15mm
|
-
|
IP66/IP67 - Dust Tight, Water Resistant, Waterproof
|
CSA, UL
|
|
|
|
XCSDMC
|
Active
|
Box
|
Magnetic
|
DPST-NO/NC
|
100mA (DC)
|
24VDC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
5mm
|
15mm
|
-
|
IP66/IP67 - Dust Tight, Water Resistant, Waterproof
|
CSA, UL
|
|
|
|
XCSDMC
|
Active
|
Box
|
Magnetic
|
DPST-NO/NC
|
100mA (DC)
|
24VDC
|
-
|
-
|
Non-Contact
|
Connector (M8)
|
-
|
-
|
-
|
-
|
IP67 - Dust Tight, Waterproof
|
CSA, UL
|
|
|
|
XCSDMC
|
Active
|
Box
|
Magnetic
|
DPST-NO/NC
|
100mA (DC)
|
24VDC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
5mm
|
15mm
|
-
|
IP66/IP67 - Dust Tight, Water Resistant, Waterproof
|
CSA, UL
|
|
|
|
XCSDMC
|
Active
|
Box
|
Magnetic
|
DPST-NO/NC
|
100mA (DC)
|
24VDC
|
-
|
-
|
Non-Contact
|
Connector (M8)
|
-
|
-
|
-
|
-
|
IP66/IP67 - Dust Tight, Water Resistant, Waterproof
|
CSA, UL
|
|
|
|
XCSC
|
Active
|
Box
|
Key Locking
|
3PST-2NC/1NO
|
6A (AC), 550mA (DC)
|
240VAC, 250VDC
|
-
|
-
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
1/2" NPT
|
IP67 - Dust Tight, Waterproof
|
CSA, UL
|
|
|
|
XCSB
|
Active
|
Box
|
Solenoid Locking
|
3PST-NC
|
6A (AC), 550mA (DC)
|
240VAC, 250VDC
|
-
|
-
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
1/2" NPT
|
IP67 - Dust Tight, Waterproof
|
CSA, UL
|
|
|
|
XCSB
|
Active
|
Box
|
Solenoid Locking
|
3PST-2NC/1NO
|
6A (AC), 550mA (DC)
|
240VAC, 250VDC
|
-
|
-
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
1/2" NPT
|
IP67 - Dust Tight, Waterproof
|
CSA, UL
|
|
|
|
XCSB
|
Active
|
Box
|
Solenoid Locking
|
3PST-2NC/1NO
|
6A (AC), 550mA (DC)
|
240VAC, 250VDC
|
-
|
-
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
1/2" NPT
|
IP67 - Dust Tight, Waterproof
|
CSA, UL
|
|
|
|
XCSB
|
Active
|
Box
|
Solenoid Release
|
3PST-2NC/1NO
|
6A (AC)
|
120VAC, 125VDC
|
-
|
2kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
1/2" NPT
|
IP67 - Dust Tight, Waterproof
|
CSA, UL
|
|
|
|
XCSB
|
Active
|
Box
|
Solenoid Locking
|
3PST-1NC/2NO
|
6A (AC), 550mA (DC)
|
240VAC, 250VDC
|
-
|
-
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
1/2" NPT
|
IP67 - Dust Tight, Waterproof
|
CSA, UL
|
|
|
|
XCSA
|
Active
|
Box
|
Non-Locking
|
3PST-NC
|
6A (AC), 550mA (DC)
|
240VAC, 250VDC
|
-
|
-
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
1/2" NPT
|
IP67 - Dust Tight, Waterproof
|
CSA, UL
|
|
|
|
XCSA
|
Active
|
Box
|
Non-Locking
|
3PST-NC
|
6A (AC), 550mA (DC)
|
240VAC, 250VDC
|
-
|
-
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20
|
IP67 - Dust Tight, Waterproof
|
CSA, UL
|
|
|
|
XCSA
|
Active
|
Box
|
Non-Locking
|
3PST-NC
|
6A (AC), 550mA (DC)
|
240VAC, 250VDC
|
-
|
-
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
-
|
IP67 - Dust Tight, Waterproof
|
CSA, UL
|
|
|
|
XCSA
|
Active
|
Box
|
Non-Locking
|
3PST-2NO/1NC
|
6A (AC), 550mA (DC)
|
120VAC, 125VDC
|
-
|
-
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
-
|
IP67 - Dust Tight, Waterproof
|
CSA, UL
|
|
|
|
XCSA
|
Active
|
Box
|
Non-Locking
|
3PST-2NO/1NC
|
6A (AC), 550mA (DC)
|
120VAC, 125VDC
|
-
|
-
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
-
|
IP67 - Dust Tight, Waterproof
|
CSA, UL
|
|
|
|
XCSA
|
Active
|
Box
|
Non-Locking
|
3PST-2NO/1NC
|
6A (AC), 550mA (DC)
|
120VAC, 125VDC
|
-
|
-
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
-
|
IP67 - Dust Tight, Waterproof
|
CSA, UL
|
|
|
|
XCSA
|
Active
|
Box
|
Non-Locking
|
3PST-2NC/1NO
|
6A (AC), 550mA (DC)
|
240VAC, 250VDC
|
-
|
-
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20
|
IP67 - Dust Tight, Waterproof
|
CSA, UL
|
|
|
|
XCSA
|
Active
|
Box
|
Non-Locking
|
3PST-2NO/1NC
|
6A (AC), 550mA (DC)
|
120VAC, 125VDC
|
-
|
-
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
-
|
IP67 - Dust Tight, Waterproof
|
CSA, UL
|
|
|
|
XCSA
|
Active
|
Box
|
Non-Locking
|
3PST-1NC/2NO
|
6A (AC), 550mA (DC)
|
240VAC, 250VDC
|
-
|
-
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
1/2" NPT
|
IP67 - Dust Tight, Waterproof
|
CSA, UL
|
|
|
|
XCSA
|
Active
|
Box
|
Non-Locking
|
3PST-2NO/1NC
|
6A (AC), 550mA (DC)
|
120VAC, 125VDC
|
-
|
-
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
-
|
IP67 - Dust Tight, Waterproof
|
CSA, UL
|
|
|
|
XCSA
|
Active
|
Box
|
Non-Locking
|
3PST-2NO/1NC
|
6A (AC), 550mA (DC)
|
120VAC, 125VDC
|
-
|
-
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
-
|
IP67 - Dust Tight, Waterproof
|
CSA, UL
|
|
|
|
-
|
Active
|
Box
|
Magnetic
|
-
|
-
|
-
|
26.5 ~ 31.6VDC
|
-
|
Non-Contact
|
Cable with Connector (M12)
|
-
|
-
|
-
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TR4
|
Active
|
Box
|
RFID
|
-
|
-
|
-
|
24VDC
|
-
|
Non-Contact
|
Cable with Connector (M12)
|
-
|
15mm
|
25mm
|
-
|
IP67/IP69K - Dust Tight, Water Resistant, Waterproof
|
CE, cULus
|
|
|
|
TL8012-S
|
Active
|
Bulk
|
Solenoid Release
|
5PST-4NC/1NO
|
5A (AC), 2A (DC)
|
100VAC, 24VDC
|
220VAC
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL8012-S
|
Active
|
Bulk
|
Solenoid Release
|
5PST-4NC/1NO
|
5A (AC), 2A (DC)
|
100VAC, 24VDC
|
220VAC
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL8012-S
|
Active
|
Bulk
|
Solenoid Release
|
5PST-4NC/1NO
|
5A (AC), 2A (DC)
|
100VAC, 24VDC
|
220VAC
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL8012-S
|
Last Time Buy
|
Bulk
|
Solenoid Release
|
5PST-4NC/1NO
|
5A (AC), 2A (DC)
|
100VAC, 24VDC
|
110VAC
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL8012-S
|
Last Time Buy
|
Bulk
|
Solenoid Release
|
5PST-4NC/1NO
|
5A (AC), 2A (DC)
|
100VAC, 24VDC
|
110VAC
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL8012-S
|
Last Time Buy
|
Bulk
|
Solenoid Release
|
5PST-4NC/1NO
|
5A (AC), 2A (DC)
|
100VAC, 24VDC
|
110VAC
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL8012-S
|
Last Time Buy
|
Bulk
|
Solenoid Release
|
5PST-4NC/1NO
|
5A (AC), 2A (DC)
|
100VAC, 24VDC
|
24VAC/DC
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL8012-S
|
Last Time Buy
|
Bulk
|
Solenoid Release
|
5PST-4NC/1NO
|
5A (AC), 2A (DC)
|
100VAC, 24VDC
|
24VAC/DC
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL8012-S
|
Last Time Buy
|
Bulk
|
Solenoid Release
|
5PST-4NC/1NO
|
5A (AC), 2A (DC)
|
100VAC, 24VDC
|
24VAC/DC
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL8012-S
|
Active
|
Bulk
|
Solenoid Locking
|
5PST-3NC/2NO
|
5A (AC), 2A (DC)
|
100VAC, 24VDC
|
220VAC
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL8012-S
|
Active
|
Bulk
|
Solenoid Locking
|
5PST-3NC/2NO
|
5A (AC), 2A (DC)
|
100VAC, 24VDC
|
220VAC
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL8012-S
|
Active
|
Bulk
|
Solenoid Locking
|
5PST-3NC/2NO
|
5A (AC), 2A (DC)
|
100VAC, 24VDC
|
220VAC
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL8012-S
|
Last Time Buy
|
Bulk
|
Solenoid Locking
|
5PST-3NC/2NO
|
5A (AC), 2A (DC)
|
100VAC, 24VDC
|
110VAC
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL8012-S
|
Last Time Buy
|
Bulk
|
Solenoid Locking
|
5PST-3NC/2NO
|
5A (AC), 2A (DC)
|
100VAC, 24VDC
|
110VAC
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL8012-S
|
Last Time Buy
|
Bulk
|
Solenoid Locking
|
5PST-3NC/2NO
|
5A (AC), 2A (DC)
|
100VAC, 24VDC
|
110VAC
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL8012-S
|
Last Time Buy
|
Bulk
|
Solenoid Locking
|
5PST-3NC/2NO
|
5A (AC), 2A (DC)
|
100VAC, 24VDC
|
24VAC/DC
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL8012-S
|
Last Time Buy
|
Bulk
|
Solenoid Locking
|
5PST-3NC/2NO
|
5A (AC), 2A (DC)
|
100VAC, 24VDC
|
24VAC/DC
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL8012-S
|
Last Time Buy
|
Bulk
|
Solenoid Locking
|
5PST-3NC/2NO
|
5A (AC), 2A (DC)
|
100VAC, 24VDC
|
24VAC/DC
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL8012-S
|
Last Time Buy
|
Bulk
|
Solenoid Release
|
5PST-3NC/2NO
|
5A (AC), 2A (DC)
|
100VAC, 24VDC
|
220VAC
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL8012-S
|
Last Time Buy
|
Bulk
|
Solenoid Release
|
5PST-3NC/2NO
|
5A (AC), 2A (DC)
|
100VAC, 24VDC
|
220VAC
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL8012-S
|
Last Time Buy
|
Bulk
|
Solenoid Release
|
5PST-3NC/2NO
|
5A (AC), 2A (DC)
|
100VAC, 24VDC
|
220VAC
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL8012-S
|
Last Time Buy
|
Bulk
|
Solenoid Release
|
5PST-3NC/2NO
|
5A (AC), 2A (DC)
|
100VAC, 24VDC
|
220VAC
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL8012-S
|
Last Time Buy
|
Bulk
|
Solenoid Release
|
5PST-3NC/2NO
|
5A (AC), 2A (DC)
|
100VAC, 24VDC
|
220VAC
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL8012-S
|
Last Time Buy
|
Bulk
|
Solenoid Release
|
5PST-3NC/2NO
|
5A (AC), 2A (DC)
|
100VAC, 24VDC
|
220VAC
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL8012-S
|
Last Time Buy
|
Bulk
|
Solenoid Release
|
5PST-3NC/2NO
|
5A (AC), 2A (DC)
|
100VAC, 24VDC
|
110VAC
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL8012-S
|
Last Time Buy
|
Bulk
|
Solenoid Release
|
5PST-3NC/2NO
|
5A (AC), 2A (DC)
|
100VAC, 24VDC
|
110VAC
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL8012-S
|
Last Time Buy
|
Bulk
|
Solenoid Release
|
5PST-3NC/2NO
|
5A (AC), 2A (DC)
|
100VAC, 24VDC
|
110VAC
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL8012-S
|
Last Time Buy
|
Bulk
|
Solenoid Release
|
5PST-3NC/2NO
|
5A (AC), 2A (DC)
|
100VAC, 24VDC
|
110VAC
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL8012-S
|
Last Time Buy
|
Bulk
|
Solenoid Release
|
5PST-3NC/2NO
|
5A (AC), 2A (DC)
|
100VAC, 24VDC
|
110VAC
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL8012-S
|
Last Time Buy
|
Bulk
|
Solenoid Release
|
5PST-3NC/2NO
|
5A (AC), 2A (DC)
|
100VAC, 24VDC
|
110VAC
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL8012-S
|
Last Time Buy
|
Bulk
|
Solenoid Release
|
5PST-3NC/2NO
|
5A (AC), 2A (DC)
|
100VAC, 24VDC
|
24VAC/DC
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL8012-S
|
Last Time Buy
|
Bulk
|
Solenoid Release
|
5PST-3NC/2NO
|
5A (AC), 2A (DC)
|
100VAC, 24VDC
|
24VAC/DC
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL8012-S
|
Last Time Buy
|
Bulk
|
Solenoid Release
|
5PST-3NC/2NO
|
5A (AC), 2A (DC)
|
100VAC, 24VDC
|
24VAC/DC
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL8012-S
|
Last Time Buy
|
Bulk
|
Solenoid Release
|
5PST-3NC/2NO
|
5A (AC), 2A (DC)
|
100VAC, 24VDC
|
24VAC/DC
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL8012-S
|
Last Time Buy
|
Bulk
|
Solenoid Release
|
5PST-3NC/2NO
|
5A (AC), 2A (DC)
|
100VAC, 24VDC
|
24VAC/DC
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL8012-S
|
Last Time Buy
|
Bulk
|
Solenoid Release
|
5PST-3NC/2NO
|
5A (AC), 2A (DC)
|
100VAC, 24VDC
|
24VAC/DC
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL5012
|
Active
|
Bulk
|
Solenoid Release
|
3PST-NC
|
5A (AC), 2A (DC)
|
100VAC, 24VDC
|
220VAC
|
102kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL5012
|
Active
|
Bulk
|
Solenoid Release
|
3PST-NC
|
5A (AC), 2A (DC)
|
100VAC, 24VDC
|
110VAC
|
102kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL5012
|
Active
|
Bulk
|
Solenoid Release
|
3PST-NC
|
5A (AC), 2A (DC)
|
100VAC, 24VDC
|
24VAC/DC
|
102kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL5012
|
Active
|
Bulk
|
Solenoid Release
|
3PST-2NC/1NO
|
5A (AC), 2A (DC)
|
100VAC, 24VDC
|
220VAC
|
102kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL5012
|
Active
|
Bulk
|
Solenoid Release
|
3PST-2NC/1NO
|
5A (AC), 2A (DC)
|
100VAC, 24VDC
|
110VAC
|
102kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL5012
|
Active
|
Bulk
|
Solenoid Release
|
3PST-2NC/1NO
|
5A (AC), 2A (DC)
|
100VAC, 24VDC
|
24VAC/DC
|
102kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4024
|
Active
|
Bulk
|
Solenoid Release
|
4PST-2NO/2NC (DB/DM)
|
4A (AC/DC)
|
230VAC, 24VDC
|
24VAC/DC
|
153kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
1/2" NPT x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4024
|
Active
|
Bulk
|
Solenoid Locking
|
4PST-3NC/1NO (DB/DM)
|
4A (AC/DC)
|
230VAC, 24VDC
|
24VAC/DC
|
153kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
1/2" NPT x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4024
|
Active
|
Bulk
|
Solenoid Release
|
4PST-2NO/2NC (DB/DM)
|
4A (AC/DC)
|
230VAC, 24VDC
|
110VAC
|
153kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
1/2" NPT x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4024
|
Active
|
Bulk
|
Solenoid Release
|
4PST-3NC/1NO (DB/DM)
|
4A (AC/DC)
|
230VAC, 24VDC
|
110VAC
|
153kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
1/2" NPT x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4024
|
Active
|
Bulk
|
Solenoid Release
|
4PST-2NO/2NC (DB/DM)
|
4A (AC/DC)
|
230VAC, 24VDC
|
24VAC/DC
|
153kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
1/2" NPT x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4024
|
Active
|
Bulk
|
Solenoid Release
|
4PST-3NC/1NO (DB/DM)
|
4A (AC/DC)
|
230VAC, 24VDC
|
24VAC/DC
|
153kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
1/2" NPT x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4024
|
Active
|
Bulk
|
Solenoid Release
|
4PST-3NC/1NO (DB/DM)
|
4A (AC/DC)
|
230VAC, 24VDC
|
24VAC/DC
|
153kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
1/2" NPT x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4024
|
Active
|
Bulk
|
Solenoid Release
|
4PST-3NC/1NO (DB/DM)
|
4A (AC/DC)
|
230VAC, 24VDC
|
24VAC/DC
|
153kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
1/2" NPT x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4024
|
Active
|
Bulk
|
Solenoid Release
|
4PST-3NC/1NO (DB/DM)
|
4A (AC/DC)
|
230VAC, 24VDC
|
24VAC/DC
|
153kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
1/2" NPT x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Release
|
3PST-2NC/1NO (DB/DM)
|
4A (AC/DC)
|
230VAC, 24VDC
|
24VAC/DC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Release
|
3PST-2NC/1NO (DB/DM)
|
4A (AC/DC)
|
230VAC, 24VDC
|
24VAC/DC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Release
|
3PST-2NC/1NO
|
4A (AC/DC)
|
230VAC, 24VDC
|
24VAC/DC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Release
|
3PST-2NC/1NO (DB/DM)
|
4A (AC/DC)
|
230VAC, 24VDC
|
24VAC/DC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Release
|
3PST-2NC/1NO (DB/DM)
|
4A (AC/DC)
|
230VAC, 24VDC
|
24VAC/DC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Release
|
3PST-2NC/1NO (DB/DM)
|
4A (AC/DC)
|
230VAC, 24VDC
|
24VAC/DC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Locking
|
4PST-3NC/1NO (DB/DM)
|
4A (AC/DC)
|
230VAC, 24VDC
|
110VAC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Locking
|
4PST-3NC/1NO (DB/DM)
|
4A (AC/DC)
|
230VAC, 24VDC
|
110VAC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Locking
|
4PST-3NC/1NO (DB/DM)
|
4A (AC/DC)
|
230VAC, 24VDC
|
110VAC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Locking
|
4PST-3NC/1NO (DB/DM)
|
4A (AC/DC)
|
230VAC, 24VDC
|
110VAC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Locking
|
4PST-3NC/1NO (DB/DM)
|
4A (AC/DC)
|
230VAC, 24VDC
|
110VAC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Locking
|
4PST-3NC/1NO (DB/DM)
|
4A (AC/DC)
|
230VAC, 24VDC
|
110VAC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Locking
|
4PST-3NC/1NO (DB/DM)
|
4A (AC/DC)
|
230VAC, 24VDC
|
110VAC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Locking
|
4PST-3NC/1NO (DB/DM)
|
4A (AC/DC)
|
230VAC, 24VDC
|
110VAC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Locking
|
4PST-3NC/1NO (DB/DM)
|
4A (AC/DC)
|
230VAC, 24VDC
|
110VAC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Locking
|
4PST-3NC/1NO (DB/DM)
|
4A (AC/DC)
|
230VAC, 24VDC
|
110VAC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Locking
|
4PST-2NO/2NC
|
4A (AC/DC)
|
230VAC, 24VDC
|
110VAC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Locking
|
4PST-2NO/2NC
|
4A (AC/DC)
|
230VAC, 24VDC
|
110VAC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Locking
|
4PST-2NO/2NC
|
4A (AC/DC)
|
230VAC, 24VDC
|
110VAC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Locking
|
4PST-2NO/2NC
|
4A (AC/DC)
|
230VAC, 24VDC
|
110VAC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Locking
|
4PST-2NO/2NC (DB/DM)
|
4A (AC/DC)
|
230VAC, 24VDC
|
110VAC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Locking
|
4PST-3NC/1NO (DB/DM)
|
4A (AC/DC)
|
230VAC, 24VDC
|
24VAC/DC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Locking
|
4PST-3NC/1NO (DB/DM)
|
4A (AC/DC)
|
230VAC, 24VDC
|
24VAC/DC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Locking
|
4PST-3NC/1NO
|
4A (AC/DC)
|
230VAC, 24VDC
|
24VAC/DC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Locking
|
4PST-3NC/1NO (DB/DM)
|
4A (AC/DC)
|
230VAC, 24VDC
|
24VAC/DC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
*
|
Active
|
Bulk
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Locking
|
4PST-3NC/1NO (DB/DM)
|
4A (AC/DC)
|
230VAC, 24VDC
|
24VAC/DC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Locking
|
4PST-3NC/1NO (DB/DM)
|
4A (AC/DC)
|
230VAC, 24VDC
|
24VAC/DC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Locking
|
4PST-3NC/1NO (DB/DM)
|
4A (AC/DC)
|
230VAC, 24VDC
|
24VAC/DC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Locking
|
4PST-3NC/1NO (DB/DM)
|
4A (AC/DC)
|
230VAC, 24VDC
|
24VAC/DC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Locking
|
4PST-3NC/1NO (DB/DM)
|
4A (AC/DC)
|
230VAC, 24VDC
|
24VAC/DC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Locking
|
4PST-3NC/1NO (DB/DM)
|
4A (AC/DC)
|
230VAC, 24VDC
|
24VAC/DC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Locking
|
4PST-3NC/1NO (DB/DM)
|
4A (AC/DC)
|
230VAC, 24VDC
|
24VAC/DC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Locking
|
4PST-3NC/1NO (DB/DM)
|
4A (AC/DC)
|
230VAC, 24VDC
|
24VAC/DC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Locking
|
4PST-2NO/2NC (DB/DM)
|
4A (AC/DC)
|
230VAC, 24VDC
|
24VAC/DC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Locking
|
4PST-2NO/2NC (DB/DM)
|
4A (AC/DC)
|
230VAC, 24VDC
|
24VAC/DC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Locking
|
4PST-2NO/2NC
|
4A (AC/DC)
|
230VAC, 24VDC
|
24VAC/DC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Locking
|
4PST-2NO/2NC
|
4A (AC/DC)
|
230VAC, 24VDC
|
24VAC/DC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Locking
|
4PST-2NO/2NC (DB/DM)
|
4A (AC/DC)
|
230VAC, 24VDC
|
24VAC/DC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Locking
|
4PST-2NO/2NC
|
4A (AC/DC)
|
230VAC, 24VDC
|
24VAC/DC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Locking
|
4PST-2NO/2NC
|
4A (AC/DC)
|
230VAC, 24VDC
|
24VAC/DC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Locking
|
4PST-2NO/2NC
|
4A (AC/DC)
|
230VAC, 24VDC
|
24VAC/DC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Locking
|
4PST-2NO/2NC (DB/DM)
|
4A (AC/DC)
|
230VAC, 24VDC
|
24VAC/DC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Locking
|
4PST-2NO/2NC (DB/DM)
|
4A (AC/DC)
|
230VAC, 24VDC
|
24VAC/DC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Release
|
4PST-3NC/1NO (DB/DM)
|
4A (AC/DC)
|
230VAC, 24VDC
|
110VAC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Release
|
4PST-3NC/1NO (DB/DM)
|
4A (AC/DC)
|
230VAC, 24VDC
|
110VAC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Release
|
4PST-3NC/1NO
|
4A (AC/DC)
|
230VAC, 24VDC
|
110VAC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Release
|
4PST-3NC/1NO (DB/DM)
|
4A (AC/DC)
|
230VAC, 24VDC
|
110VAC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Release
|
4PST-3NC/1NO (DB/DM)
|
4A (AC/DC)
|
230VAC, 24VDC
|
110VAC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Release
|
4PST-3NC/1NO (DB/DM)
|
4A (AC/DC)
|
230VAC, 24VDC
|
110VAC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Release
|
4PST-3NC/1NO (DB/DM)
|
4A (AC/DC)
|
230VAC, 24VDC
|
110VAC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Release
|
4PST-3NC/1NO (DB/DM)
|
4A (AC/DC)
|
230VAC, 24VDC
|
110VAC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Release
|
4PST-3NC/1NO
|
4A (AC/DC)
|
230VAC, 24VDC
|
110VAC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Release
|
4PST-3NC/1NO
|
4A (AC/DC)
|
230VAC, 24VDC
|
110VAC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Release
|
4PST-3NC/1NO (DB/DM)
|
4A (AC/DC)
|
230VAC, 24VDC
|
110VAC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Release
|
4PST-3NC/1NO (DB/DM)
|
4A (AC/DC)
|
230VAC, 24VDC
|
110VAC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Release
|
4PST-3NC/1NO (DB/DM)
|
4A (AC/DC)
|
230VAC, 24VDC
|
110VAC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Release
|
4PST-2NO/2NC (DB/DM)
|
4A (AC/DC)
|
230VAC, 24VDC
|
110VAC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Release
|
4PST-2NO/2NC (DB/DM)
|
4A (AC/DC)
|
230VAC, 24VDC
|
110VAC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Release
|
4PST-2NO/2NC
|
4A (AC/DC)
|
230VAC, 24VDC
|
110VAC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Release
|
4PST-2NO/2NC (DB/DM)
|
4A (AC/DC)
|
230VAC, 24VDC
|
110VAC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Release
|
4PST-2NO/2NC (DB/DM)
|
4A (AC/DC)
|
230VAC, 24VDC
|
110VAC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Release
|
4PST-2NO/2NC (DB/DM)
|
4A (AC/DC)
|
230VAC, 24VDC
|
110VAC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Release
|
3PST-2NC/1NO
|
4A (AC/DC)
|
230VAC, 24VDC
|
24VAC/DC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Release
|
4PST-3NC/1NO (DB/DM)
|
4A (AC/DC)
|
230VAC, 24VDC
|
24VAC/DC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Release
|
4PST-3NC/1NO
|
4A (AC/DC)
|
230VAC, 24VDC
|
24VAC/DC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Release
|
4PST-3NC/1NO
|
4A (AC/DC)
|
230VAC, 24VDC
|
24VAC/DC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Release
|
4PST-3NC/1NO (DB/DM)
|
4A (AC/DC)
|
230VAC, 24VDC
|
24VAC/DC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Release
|
4PST-3NC/1NO (DB/DM)
|
4A (AC/DC)
|
230VAC, 24VDC
|
24VAC/DC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Release
|
4PST-3NC/1NO
|
4A (AC/DC)
|
230VAC, 24VDC
|
24VAC/DC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Release
|
4PST-3NC/1NO (DB/DM)
|
4A (AC/DC)
|
230VAC, 24VDC
|
24VAC/DC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Release
|
4PST-3NC/1NO (DB/DM)
|
4A (AC/DC)
|
230VAC, 24VDC
|
24VAC/DC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Release
|
4PST-3NC/1NO (DB/DM)
|
4A (AC/DC)
|
230VAC, 24VDC
|
24VAC/DC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Release
|
4PST-3NC/1NO (DB/DM)
|
4A (AC/DC)
|
230VAC, 24VDC
|
24VAC/DC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Release
|
4PST-3NC/1NO (DB/DM)
|
4A (AC/DC)
|
230VAC, 24VDC
|
24VAC/DC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Release
|
4PST-3NC/1NO
|
4A (AC/DC)
|
230VAC, 24VDC
|
24VAC/DC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Release
|
4PST-3NC/1NO (DB/DM)
|
4A (AC/DC)
|
230VAC, 24VDC
|
24VAC/DC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Release
|
4PST-3NC/1NO
|
4A (AC/DC)
|
230VAC, 24VDC
|
24VAC/DC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Release
|
4PST-3NC/1NO (DB/DM)
|
4A (AC/DC)
|
230VAC, 24VDC
|
24VAC/DC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Release
|
4PST-3NC/1NO (DB/DM)
|
4A (AC/DC)
|
230VAC, 24VDC
|
24VAC/DC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Release
|
4PST-3NC/1NO
|
4A (AC/DC)
|
230VAC, 24VDC
|
24VAC/DC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Release
|
4PST-3NC/1NO (DB/DM)
|
4A (AC/DC)
|
230VAC, 24VDC
|
24VAC/DC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Release
|
4PST-2NO/2NC
|
4A (AC/DC)
|
230VAC, 24VDC
|
24VAC/DC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Release
|
4PST-2NO/2NC (DB/DM)
|
4A (AC/DC)
|
230VAC, 24VDC
|
24VAC/DC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Release
|
4PST-2NO/2NC
|
4A (AC/DC)
|
230VAC, 24VDC
|
24VAC/DC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Release
|
4PST-2NO/2NC
|
4A (AC/DC)
|
230VAC, 24VDC
|
24VAC/DC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Release
|
4PST-2NO/2NC
|
4A (AC/DC)
|
230VAC, 24VDC
|
24VAC/DC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Release
|
4PST-2NO/2NC (DB/DM)
|
4A (AC/DC)
|
230VAC, 24VDC
|
24VAC/DC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Release
|
4PST-2NO/2NC (DB/DM)
|
4A (AC/DC)
|
230VAC, 24VDC
|
24VAC/DC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Release
|
4PST-2NO/2NC (DB/DM)
|
4A (AC/DC)
|
230VAC, 24VDC
|
24VAC/DC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Release
|
4PST-2NO/2NC (DB/DM)
|
4A (AC/DC)
|
230VAC, 24VDC
|
24VAC/DC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Locking
|
4PST-2NO/2NC
|
4A (AC/DC)
|
230VAC, 24VDC
|
110VAC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Locking
|
4PST-2NO/2NC
|
4A (AC/DC)
|
230VAC, 24VDC
|
110VAC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Locking
|
4PST-2NO/2NC
|
4A (AC/DC)
|
230VAC, 24VDC
|
110VAC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Locking
|
4PST-2NO/2NC
|
4A (AC/DC)
|
230VAC, 24VDC
|
110VAC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Locking
|
4PST-2NO/2NC
|
4A (AC/DC)
|
230VAC, 24VDC
|
110VAC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Locking
|
4PST-2NO/2NC
|
4A (AC/DC)
|
230VAC, 24VDC
|
24VAC/DC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Locking
|
4PST-2NO/2NC
|
4A (AC/DC)
|
230VAC, 24VDC
|
24VAC/DC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Locking
|
4PST-2NO/2NC
|
4A (AC/DC)
|
230VAC, 24VDC
|
24VAC/DC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Locking
|
4PST-2NO/2NC
|
4A (AC/DC)
|
230VAC, 24VDC
|
24VAC/DC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Locking
|
4PST-2NO/2NC
|
4A (AC/DC)
|
230VAC, 24VDC
|
24VAC/DC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Locking
|
4PST-2NO/2NC
|
4A (AC/DC)
|
230VAC, 24VDC
|
24VAC/DC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Locking
|
4PST-2NO/2NC
|
4A (AC/DC)
|
230VAC, 24VDC
|
24VAC/DC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Release
|
4PST-2NO/2NC
|
4A (AC/DC)
|
230VAC, 24VDC
|
110VAC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Release
|
4PST-2NO/2NC
|
4A (AC/DC)
|
230VAC, 24VDC
|
110VAC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Release
|
4PST-2NO/2NC
|
4A (AC/DC)
|
230VAC, 24VDC
|
110VAC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Release
|
4PST-2NO/2NC
|
4A (AC/DC)
|
230VAC, 24VDC
|
110VAC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Release
|
4PST-2NO/2NC
|
4A (AC/DC)
|
230VAC, 24VDC
|
110VAC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Release
|
4PST-2NO/2NC
|
4A (AC/DC)
|
230VAC, 24VDC
|
110VAC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Release
|
4PST-2NO/2NC
|
4A (AC/DC)
|
230VAC, 24VDC
|
24VAC/DC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Release
|
4PST-2NO/2NC
|
4A (AC/DC)
|
230VAC, 24VDC
|
24VAC/DC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Release
|
4PST-2NO/2NC
|
4A (AC/DC)
|
230VAC, 24VDC
|
24VAC/DC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Release
|
4PST-2NO/2NC
|
4A (AC/DC)
|
230VAC, 24VDC
|
24VAC/DC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Release
|
4PST-2NO/2NC
|
4A (AC/DC)
|
230VAC, 24VDC
|
24VAC/DC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Release
|
4PST-2NO/2NC
|
4A (AC/DC)
|
230VAC, 24VDC
|
24VAC/DC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
TL4019
|
Active
|
Bulk
|
Solenoid Release
|
4PST-2NO/2NC
|
4A (AC/DC)
|
230VAC, 24VDC
|
24VAC/DC
|
122kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
T5009
|
Obsolete
|
Bulk
|
Non-Locking
|
3PST-2NC/1NO (BBM)
|
6A (AC), 2.5A (DC)
|
120VAC, 24VDC
|
-
|
1kgf
|
Panel Disconnect
|
Connector (Micro AC)
|
Stainless Steel Head
|
-
|
-
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
T5009
|
Obsolete
|
Bulk
|
Non-Locking
|
3PST-2NC/1NO (BBM)
|
6A (AC), 2.5A (DC)
|
120VAC, 24VDC
|
-
|
1kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
T5009
|
Obsolete
|
Bulk
|
Non-Locking
|
3PST-2NC/1NO (BBM)
|
6A (AC), 2.5A (DC)
|
120VAC, 24VDC
|
-
|
1kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
1/2" NPT x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
T5009
|
Obsolete
|
Bulk
|
Non-Locking
|
3PST-2NC/1NO (BBM)
|
6A (AC), 2.5A (DC)
|
120VAC, 24VDC
|
-
|
1kgf
|
Panel Disconnect
|
Screw Terminal
|
Flex Actuator
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
T4016
|
Active
|
Bulk
|
Non-Locking
|
3PST-NC + SPST-NO
|
4A (AC/DC)
|
230VAC, 24VDC
|
-
|
5kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
1/2" NPT x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
T4016
|
Active
|
Bulk
|
Non-Locking
|
3PST-NC + SPST-NO
|
4A (AC/DC)
|
230VAC, 24VDC
|
-
|
5kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
1/2" NPT x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
T4012
|
Obsolete
|
Bulk
|
Non-Locking
|
4PST-3NC/1NO
|
4A (AC/DC)
|
230VAC, 24VDC
|
-
|
3kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
T4012
|
Obsolete
|
Bulk
|
Non-Locking
|
4PST-3NC/1NO
|
4A (AC/DC)
|
230VAC, 24VDC
|
-
|
3kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
T4012
|
Obsolete
|
Bulk
|
Non-Locking
|
4PST-2NO/2NC
|
4A (AC/DC)
|
230VAC, 24VDC
|
-
|
3kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
T4012
|
Obsolete
|
Bulk
|
Non-Locking
|
4PST-2NO/2NC
|
4A (AC/DC)
|
230VAC, 24VDC
|
-
|
3kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
T4012
|
Obsolete
|
Bulk
|
Non-Locking
|
DPST-NC
|
4A (AC/DC)
|
230VAC, 24VDC
|
-
|
3kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
T4012
|
Obsolete
|
Bulk
|
Non-Locking
|
DPST-NC
|
4A (AC/DC)
|
230VAC, 24VDC
|
-
|
3kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
T4012
|
Obsolete
|
Bulk
|
Non-Locking
|
DPST-NC
|
4A (AC/DC)
|
230VAC, 24VDC
|
-
|
3kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
T4012
|
Obsolete
|
Bulk
|
Non-Locking
|
DPST-NC
|
4A (AC/DC)
|
230VAC, 24VDC
|
-
|
3kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
T4012
|
Obsolete
|
Bulk
|
Non-Locking
|
DPST-NO/NC
|
4A (AC/DC)
|
230VAC, 24VDC
|
-
|
3kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
T4012
|
Obsolete
|
Bulk
|
Non-Locking
|
DPST-NO/NC
|
4A (AC/DC)
|
230VAC, 24VDC
|
-
|
3kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
T4012
|
Obsolete
|
Bulk
|
Non-Locking
|
DPST-NO/NC
|
4A (AC/DC)
|
230VAC, 24VDC
|
-
|
3kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
T4012
|
Obsolete
|
Bulk
|
Non-Locking
|
DPST-NO/NC
|
4A (AC/DC)
|
230VAC, 24VDC
|
-
|
3kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
T4012
|
Obsolete
|
Bulk
|
Non-Locking
|
DPST-NO/NC
|
4A (AC/DC)
|
230VAC, 24VDC
|
-
|
3kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
T4011
|
Active
|
Bulk
|
Non-Locking
|
4PST-3NC/1NO (BBM)
|
5A (AC), 2A (DC)
|
100VAC, 24VDC
|
-
|
1kgf
|
Panel Disconnect
|
Screw Terminal
|
12" Chain
|
-
|
-
|
1/2" NPT
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
T4011
|
Active
|
Bulk
|
Non-Locking
|
4PST-3NC/1NO (BBM)
|
5A (AC), 2A (DC)
|
100VAC, 24VDC
|
-
|
1kgf
|
Panel Disconnect
|
Screw Terminal
|
12" Chain
|
-
|
-
|
1/2" NPT
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
T4011
|
Active
|
Bulk
|
Non-Locking
|
4PST-2NO/2NC (BBM)
|
5A (AC), 2A (DC)
|
100VAC, 24VDC
|
-
|
1kgf
|
Panel Disconnect
|
Screw Terminal
|
12" Chain
|
-
|
-
|
1/2" NPT
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
T4011
|
Active
|
Bulk
|
Non-Locking
|
4PST-2NO/2NC (BBM)
|
5A (AC), 2A (DC)
|
100VAC, 24VDC
|
-
|
1kgf
|
Panel Disconnect
|
Screw Terminal
|
12" Chain
|
-
|
-
|
1/2" NPT
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
T4011
|
Active
|
Bulk
|
Non-Locking
|
3PST-2NC/1NO (BBM)
|
5A (AC), 2A (DC)
|
100VAC, 24VDC
|
-
|
1kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
1/2" NPT
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
T4011
|
Obsolete
|
Bulk
|
Non-Locking
|
3PST-2NC/1NO (BBM)
|
5A (AC), 2A (DC)
|
100VAC, 24VDC
|
-
|
1kgf
|
Panel Disconnect
|
Screw Terminal
|
12" Chain
|
-
|
-
|
1/2" NPT
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
T4011
|
Active
|
Bulk
|
Non-Locking
|
3PST-2NC/1NO (BBM)
|
5A (AC), 2A (DC)
|
100VAC, 24VDC
|
-
|
1kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
1/2" NPT
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
T2011
|
Obsolete
|
Bulk
|
Non-Locking
|
3PST-NC
|
4A (AC/DC)
|
230VAC, 24VDC
|
-
|
612gf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M16
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
T2011
|
Obsolete
|
Bulk
|
Non-Locking
|
DPST-NC + SPST-NO
|
4A (AC/DC)
|
230VAC, 24VDC
|
-
|
612gf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M16
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
T2011
|
Obsolete
|
Bulk
|
Non-Locking
|
DPST-NC + SPST-NO
|
4A (AC/DC)
|
230VAC, 24VDC
|
-
|
612gf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M16
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
T2008
|
Obsolete
|
Bulk
|
Non-Locking
|
DPST-NO/NC
|
4A (AC/DC)
|
230VAC, 24VDC
|
-
|
612gf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M16
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
T2008
|
Obsolete
|
Bulk
|
Non-Locking
|
DPST-NC
|
4A (AC/DC)
|
230VAC, 24VDC
|
-
|
612gf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M16
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
T2007
|
Active
|
Bulk
|
Non-Locking
|
DPST-NO/NC
|
5A (AC), 2A (DC)
|
100VAC, 24VDC
|
-
|
612gf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M16
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
T2007
|
Active
|
Bulk
|
Non-Locking
|
DPST-NO/NC
|
5A (AC), 2A (DC)
|
100VAC, 24VDC
|
-
|
612gf
|
Panel Disconnect
|
Cable with Connector (M12)
|
-
|
-
|
-
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
T2007
|
Active
|
Bulk
|
Non-Locking
|
DPST-NO/NC
|
5A (AC), 2A (DC)
|
100VAC, 24VDC
|
-
|
612gf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M16
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
T2007
|
Active
|
Bulk
|
Non-Locking
|
DPST-NO/NC
|
5A (AC), 2A (DC)
|
100VAC, 24VDC
|
-
|
612gf
|
Panel Disconnect
|
Cable with Connector (M12)
|
-
|
-
|
-
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
T2007
|
Active
|
Bulk
|
Non-Locking
|
DPST-NO/NC
|
5A (AC), 2A (DC)
|
100VAC, 24VDC
|
-
|
612gf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M16
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
T2007
|
Active
|
Bulk
|
Non-Locking
|
DPST-NC
|
5A (AC), 2A (DC)
|
100VAC, 24VDC
|
-
|
612gf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M16
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
T2007
|
Active
|
Bulk
|
Non-Locking
|
DPST-NC
|
5A (AC), 2A (DC)
|
100VAC, 24VDC
|
-
|
612gf
|
Panel Disconnect
|
Cable with Connector (M12)
|
-
|
-
|
-
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
T2007
|
Active
|
Bulk
|
Non-Locking
|
DPST-NC
|
5A (AC), 2A (DC)
|
100VAC, 24VDC
|
-
|
612gf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M16
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
T2007
|
Active
|
Bulk
|
Non-Locking
|
DPST-NC
|
5A (AC), 2A (DC)
|
100VAC, 24VDC
|
-
|
612gf
|
Panel Disconnect
|
Cable with Connector (M12)
|
-
|
-
|
-
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
T2007
|
Active
|
Bulk
|
Non-Locking
|
DPST-NC
|
5A (AC), 2A (DC)
|
100VAC, 24VDC
|
-
|
612gf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M16
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
STR1
|
Active
|
Bulk
|
RFID
|
-
|
100mA (DC)
|
-
|
24VDC
|
-
|
Non-Contact
|
Cable Leads
|
Staus Indicator
|
10mm
|
25mm
|
-
|
IP67/IP69K - Dust Tight, Water Resistant, Waterproof
|
CE, cULus, TUV
|
|
|
|
STR1
|
Active
|
Bulk
|
RFID
|
-
|
100mA (DC)
|
-
|
24VDC
|
-
|
Non-Contact
|
Cable with Connector (M12)
|
Staus Indicator
|
10mm
|
25mm
|
-
|
IP67/IP69K - Dust Tight, Water Resistant, Waterproof
|
CE, cULus, TUV
|
|
|
|
STR1
|
Active
|
Bulk
|
RFID
|
-
|
100mA (DC)
|
-
|
24VDC
|
-
|
Non-Contact
|
Cable with Connector (M12)
|
Staus Indicator
|
10mm
|
25mm
|
-
|
IP67/IP69K - Dust Tight, Water Resistant, Waterproof
|
CE, cULus, TUV
|
|
|
|
STR1
|
Active
|
Bulk
|
RFID
|
-
|
100mA (DC)
|
-
|
24VDC
|
-
|
Non-Contact
|
Cable Leads
|
Staus Indicator
|
10mm
|
25mm
|
-
|
IP67/IP69K - Dust Tight, Water Resistant, Waterproof
|
CE, cULus, TUV
|
|
|
|
STR1
|
Active
|
Bulk
|
RFID
|
-
|
100mA (DC)
|
-
|
24VDC
|
-
|
Non-Contact
|
Cable Leads
|
Staus Indicator
|
10mm
|
25mm
|
-
|
IP67/IP69K - Dust Tight, Water Resistant, Waterproof
|
CE, cULus, TUV
|
|
|
|
STR1
|
Active
|
Bulk
|
RFID
|
-
|
100mA (DC)
|
-
|
24VDC
|
-
|
Non-Contact
|
Cable with Connector (M12)
|
Staus Indicator
|
10mm
|
25mm
|
-
|
IP67/IP69K - Dust Tight, Water Resistant, Waterproof
|
CE, cULus, TUV
|
|
|
|
STR1
|
Active
|
Bulk
|
RFID
|
-
|
100mA (DC)
|
-
|
24VDC
|
-
|
Non-Contact
|
Cable with Connector (M12)
|
Staus Indicator
|
10mm
|
25mm
|
-
|
IP67/IP69K - Dust Tight, Water Resistant, Waterproof
|
CE, cULus, TUV
|
|
|
|
STR1
|
Active
|
Bulk
|
RFID
|
-
|
100mA (DC)
|
-
|
24VDC
|
-
|
Non-Contact
|
Cable Leads
|
Staus Indicator
|
10mm
|
25mm
|
-
|
IP67/IP69K - Dust Tight, Water Resistant, Waterproof
|
CE, cULus, TUV
|
|
|
|
STR1
|
Active
|
Bulk
|
RFID
|
-
|
100mA (DC)
|
-
|
24VDC
|
-
|
Non-Contact
|
Cable Leads
|
Staus Indicator
|
10mm
|
25mm
|
-
|
IP67/IP69K - Dust Tight, Water Resistant, Waterproof
|
CE, cULus, TUV
|
|
|
|
STR1
|
Active
|
Bulk
|
RFID
|
-
|
100mA (DC)
|
-
|
24VDC
|
-
|
Non-Contact
|
Cable with Connector (M12)
|
Staus Indicator
|
10mm
|
25mm
|
-
|
IP67/IP69K - Dust Tight, Water Resistant, Waterproof
|
CE, cULus, TUV
|
|
|
|
STR1
|
Active
|
Bulk
|
RFID
|
-
|
100mA (DC)
|
-
|
24VDC
|
-
|
Non-Contact
|
Cable with Connector (M12)
|
Staus Indicator
|
10mm
|
25mm
|
-
|
IP67/IP69K - Dust Tight, Water Resistant, Waterproof
|
CE, cULus, TUV
|
|
|
|
STR1
|
Active
|
Bulk
|
RFID
|
-
|
100mA (DC)
|
-
|
24VDC
|
-
|
Non-Contact
|
Cable Leads
|
Staus Indicator
|
10mm
|
25mm
|
-
|
IP67/IP69K - Dust Tight, Water Resistant, Waterproof
|
CE, cULus, TUV
|
|
|
|
STR1
|
Active
|
Bulk
|
RFID
|
-
|
100mA (DC)
|
-
|
24VDC
|
-
|
Non-Contact
|
Cable Leads
|
Staus Indicator
|
14mm
|
28mm
|
-
|
IP67/IP69K - Dust Tight, Water Resistant, Waterproof
|
CE, cULus, TUV
|
|
|
|
STR1
|
Active
|
Bulk
|
RFID
|
-
|
100mA (DC)
|
-
|
24VDC
|
-
|
Non-Contact
|
Cable with Connector (M12)
|
Staus Indicator
|
14mm
|
28mm
|
-
|
IP67/IP69K - Dust Tight, Water Resistant, Waterproof
|
CE, cULus, TUV
|
|
|
|
STR1
|
Active
|
Bulk
|
RFID
|
-
|
100mA (DC)
|
-
|
24VDC
|
-
|
Non-Contact
|
Cable with Connector (M12)
|
Staus Indicator
|
14mm
|
28mm
|
-
|
IP67/IP69K - Dust Tight, Water Resistant, Waterproof
|
CE, cULus, TUV
|
|
|
|
STR1
|
Active
|
Bulk
|
RFID
|
-
|
100mA (DC)
|
-
|
24VDC
|
-
|
Non-Contact
|
Cable Leads
|
Staus Indicator
|
14mm
|
28mm
|
-
|
IP67/IP69K - Dust Tight, Water Resistant, Waterproof
|
CE, cULus, TUV
|
|
|
|
STR1
|
Active
|
Bulk
|
RFID
|
-
|
100mA (DC)
|
-
|
24VDC
|
-
|
Non-Contact
|
Cable Leads
|
Staus Indicator
|
14mm
|
28mm
|
-
|
IP67/IP69K - Dust Tight, Water Resistant, Waterproof
|
CE, cULus, TUV
|
|
|
|
STR1
|
Active
|
Bulk
|
RFID
|
-
|
100mA (DC)
|
-
|
24VDC
|
-
|
Non-Contact
|
Cable with Connector (M12)
|
Staus Indicator
|
14mm
|
28mm
|
-
|
IP67/IP69K - Dust Tight, Water Resistant, Waterproof
|
CE, cULus, TUV
|
|
|
|
STR1
|
Active
|
Bulk
|
RFID
|
-
|
100mA (DC)
|
-
|
24VDC
|
-
|
Non-Contact
|
Cable with Connector (M12)
|
Staus Indicator
|
14mm
|
28mm
|
-
|
IP67/IP69K - Dust Tight, Water Resistant, Waterproof
|
CE, cULus, TUV
|
|
|
|
STR1
|
Active
|
Bulk
|
RFID
|
-
|
100mA (DC)
|
-
|
24VDC
|
-
|
Non-Contact
|
Cable Leads
|
Staus Indicator
|
14mm
|
28mm
|
-
|
IP67/IP69K - Dust Tight, Water Resistant, Waterproof
|
CE, cULus, TUV
|
|
|
|
STR1
|
Active
|
Bulk
|
RFID
|
-
|
100mA (DC)
|
-
|
24VDC
|
-
|
Non-Contact
|
Cable Leads
|
Staus Indicator
|
14mm
|
28mm
|
-
|
IP67/IP69K - Dust Tight, Water Resistant, Waterproof
|
CE, cULus, TUV
|
|
|
|
STR1
|
Active
|
Bulk
|
RFID
|
-
|
100mA (DC)
|
-
|
24VDC
|
-
|
Non-Contact
|
Cable with Connector (M12)
|
Staus Indicator
|
14mm
|
28mm
|
-
|
IP67/IP69K - Dust Tight, Water Resistant, Waterproof
|
CE, cULus, TUV
|
|
|
|
STR1
|
Active
|
Bulk
|
RFID
|
-
|
100mA (DC)
|
-
|
24VDC
|
-
|
Non-Contact
|
Cable with Connector (M12)
|
Staus Indicator
|
14mm
|
28mm
|
-
|
IP67/IP69K - Dust Tight, Water Resistant, Waterproof
|
CE, cULus, TUV
|
|
|
|
STR1
|
Active
|
Bulk
|
RFID
|
-
|
100mA (DC)
|
-
|
24VDC
|
-
|
Non-Contact
|
Cable Leads
|
Staus Indicator
|
14mm
|
28mm
|
-
|
IP67/IP69K - Dust Tight, Water Resistant, Waterproof
|
CE, cULus, TUV
|
|
|
|
STR1
|
Active
|
Bulk
|
RFID
|
-
|
100mA (DC)
|
-
|
24VDC
|
-
|
Non-Contact
|
Cable Leads
|
Staus Indicator
|
14mm
|
28mm
|
-
|
IP67/IP69K - Dust Tight, Water Resistant, Waterproof
|
CE, cULus, TUV
|
|
|
|
STR1
|
Active
|
Bulk
|
RFID
|
-
|
100mA (DC)
|
-
|
24VDC
|
-
|
Non-Contact
|
Cable with Connector (M12)
|
Staus Indicator
|
14mm
|
28mm
|
-
|
IP67/IP69K - Dust Tight, Water Resistant, Waterproof
|
CE, cULus, TUV
|
|
|
|
STR1
|
Active
|
Bulk
|
RFID
|
-
|
100mA (DC)
|
-
|
24VDC
|
-
|
Non-Contact
|
Cable with Connector (M12)
|
Staus Indicator
|
14mm
|
28mm
|
-
|
IP67/IP69K - Dust Tight, Water Resistant, Waterproof
|
CE, cULus, TUV
|
|
|
|
STR1
|
Active
|
Bulk
|
RFID
|
-
|
100mA (DC)
|
-
|
24VDC
|
-
|
Non-Contact
|
Cable Leads
|
Staus Indicator
|
14mm
|
28mm
|
-
|
IP67/IP69K - Dust Tight, Water Resistant, Waterproof
|
CE, cULus, TUV
|
|
|
|
STR1
|
Active
|
Bulk
|
RFID
|
-
|
100mA (DC)
|
-
|
24VDC
|
-
|
Non-Contact
|
Cable Leads
|
Staus Indicator
|
14mm
|
28mm
|
-
|
IP67/IP69K - Dust Tight, Water Resistant, Waterproof
|
CE, cULus, TUV
|
|
|
|
STR1
|
Active
|
Bulk
|
RFID
|
-
|
100mA (DC)
|
-
|
24VDC
|
-
|
Non-Contact
|
Cable with Connector (M12)
|
Staus Indicator
|
14mm
|
28mm
|
-
|
IP67/IP69K - Dust Tight, Water Resistant, Waterproof
|
CE, cULus, TUV
|
|
|
|
STR1
|
Active
|
Bulk
|
RFID
|
-
|
100mA (DC)
|
-
|
24VDC
|
-
|
Non-Contact
|
Cable with Connector (M12)
|
Staus Indicator
|
14mm
|
28mm
|
-
|
IP67/IP69K - Dust Tight, Water Resistant, Waterproof
|
CE, cULus, TUV
|
|
|
|
STR1
|
Active
|
Bulk
|
RFID
|
-
|
100mA (DC)
|
-
|
24VDC
|
-
|
Non-Contact
|
Cable Leads
|
Staus Indicator
|
14mm
|
28mm
|
-
|
IP67/IP69K - Dust Tight, Water Resistant, Waterproof
|
CE, cULus, TUV
|
|
|
|
STR1
|
Active
|
Bulk
|
RFID
|
-
|
100mA (DC)
|
-
|
24VDC
|
-
|
Non-Contact
|
Cable Leads
|
Staus Indicator
|
14mm
|
28mm
|
-
|
IP67/IP69K - Dust Tight, Water Resistant, Waterproof
|
CE, cULus, TUV
|
|
|
|
STR1
|
Active
|
Bulk
|
RFID
|
-
|
100mA (DC)
|
-
|
24VDC
|
-
|
Non-Contact
|
Cable with Connector (M12)
|
Staus Indicator
|
14mm
|
28mm
|
-
|
IP67/IP69K - Dust Tight, Water Resistant, Waterproof
|
CE, cULus, TUV
|
|
|
|
STR1
|
Active
|
Bulk
|
RFID
|
-
|
100mA (DC)
|
-
|
24VDC
|
-
|
Non-Contact
|
Cable with Connector (M12)
|
Staus Indicator
|
14mm
|
28mm
|
-
|
IP67/IP69K - Dust Tight, Water Resistant, Waterproof
|
CE, cULus, TUV
|
|
|
|
STR1
|
Active
|
Bulk
|
RFID
|
-
|
100mA (DC)
|
-
|
24VDC
|
-
|
Non-Contact
|
Cable Leads
|
Staus Indicator
|
14mm
|
28mm
|
-
|
IP67/IP69K - Dust Tight, Water Resistant, Waterproof
|
CE, cULus, TUV
|
|
|
|
SSSE
|
Active
|
Bulk
|
Trapped Key
|
3PST-2NC/1NO
|
-
|
-
|
-
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x2
|
-
|
CE
|
|
|
|
SSSE
|
Active
|
Bulk
|
Trapped Key
|
3PST-2NC/1NO
|
-
|
-
|
-
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x2
|
-
|
CE
|
|
|
|
SSSE
|
Active
|
Bulk
|
Trapped Key
|
3PST-2NC/1NO
|
-
|
-
|
-
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x2
|
-
|
CE
|
|
|
|
SSSE
|
Active
|
Bulk
|
Trapped Key
|
3PST-2NC/1NO
|
-
|
-
|
-
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x2
|
-
|
CE
|
|
|
|
SSSE
|
Active
|
Bulk
|
Trapped Key
|
3PST-2NC/1NO
|
-
|
-
|
-
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x2
|
-
|
CE
|
|
|
|
SSSE
|
Active
|
Bulk
|
Trapped Key
|
3PST-2NC/1NO
|
-
|
-
|
-
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x2
|
-
|
CE
|
|
|
|
SSSE
|
Active
|
Bulk
|
Trapped Key
|
3PST-2NC/1NO
|
-
|
-
|
-
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x2
|
-
|
CE
|
|
|
|
SSSE
|
Active
|
Bulk
|
Trapped Key
|
3PST-2NC/1NO
|
-
|
-
|
-
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x2
|
-
|
CE
|
|
|
|
SSSE
|
Active
|
Bulk
|
Trapped Key
|
3PST-2NC/1NO
|
-
|
-
|
-
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x2
|
-
|
CE
|
|
|
|
SSSE
|
Active
|
Bulk
|
Trapped Key
|
3PST-2NC/1NO
|
-
|
-
|
-
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x2
|
-
|
CE
|
|
|
|
SSSE
|
Active
|
Bulk
|
Trapped Key
|
3PST-2NC/1NO
|
-
|
-
|
-
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x2
|
-
|
CE
|
|
|
|
SSSE
|
Active
|
Bulk
|
Trapped Key
|
3PST-2NC/1NO
|
-
|
-
|
-
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x2
|
-
|
CE
|
|
|
|
SSSE
|
Active
|
Bulk
|
Trapped Key
|
3PST-2NC/1NO
|
-
|
-
|
-
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x2
|
-
|
CE
|
|
|
|
SSSE
|
Active
|
Bulk
|
Trapped Key
|
3PST-2NC/1NO
|
-
|
-
|
-
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x2
|
-
|
CE
|
|
|
|
SSSE
|
Active
|
Bulk
|
Trapped Key
|
3PST-2NC/1NO
|
-
|
-
|
-
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x2
|
-
|
CE
|
|
|
|
SSSE
|
Active
|
Bulk
|
Trapped Key
|
3PST-2NC/1NO
|
-
|
-
|
-
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x2
|
-
|
CE
|
|
|
|
SSSE
|
Active
|
Bulk
|
Trapped Key
|
3PST-2NC/1NO
|
-
|
-
|
-
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x2
|
-
|
CE
|
|
|
|
SSSE
|
Active
|
Bulk
|
Trapped Key
|
3PST-2NC/1NO
|
-
|
-
|
-
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x2
|
-
|
CE
|
|
|
|
SSSE
|
Active
|
Bulk
|
Trapped Key
|
3PST-2NC/1NO
|
-
|
-
|
-
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x2
|
-
|
CE
|
|
|
|
SSSE
|
Active
|
Bulk
|
Trapped Key
|
3PST-2NC/1NO
|
-
|
-
|
-
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x2
|
-
|
CE
|
|
|
|
SSSE
|
Active
|
Bulk
|
Trapped Key
|
3PST-2NC/1NO
|
-
|
-
|
-
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x2
|
-
|
CE
|
|
|
|
SSSE
|
Active
|
Bulk
|
Trapped Key
|
3PST-2NC/1NO
|
-
|
-
|
-
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x2
|
-
|
CE
|
|
|
|
SSSE
|
Active
|
Bulk
|
Trapped Key
|
3PST-2NC/1NO
|
-
|
-
|
-
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x2
|
-
|
CE
|
|
|
|
SSSE
|
Active
|
Bulk
|
Trapped Key
|
3PST-2NC/1NO
|
-
|
-
|
-
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x2
|
-
|
CE
|
|
|
|
SSSE
|
Active
|
Bulk
|
Trapped Key
|
3PST-2NC/1NO
|
-
|
-
|
-
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x2
|
-
|
CE
|
|
|
|
SSSE
|
Active
|
Bulk
|
Trapped Key
|
3PST-2NC/1NO
|
-
|
-
|
-
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x2
|
-
|
CE
|
|
|
|
SSSE
|
Active
|
Bulk
|
Trapped Key
|
3PST-2NC/1NO
|
-
|
-
|
-
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x2
|
-
|
CE
|
|
|
|
SSSE
|
Active
|
Bulk
|
Trapped Key
|
3PST-2NC/1NO
|
-
|
-
|
-
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x2
|
-
|
CE
|
|
|
|
SSSE
|
Active
|
Bulk
|
Trapped Key
|
3PST-2NC/1NO
|
-
|
-
|
-
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x2
|
-
|
CE
|
|
|
|
SSSE
|
Active
|
Bulk
|
Trapped Key
|
3PST-2NC/1NO
|
-
|
-
|
-
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x2
|
-
|
CE
|
|
|
|
SSSE
|
Active
|
Bulk
|
Trapped Key
|
3PST-2NC/1NO
|
-
|
-
|
-
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x2
|
-
|
CE
|
|
|
|
SSSE
|
Active
|
Bulk
|
Trapped Key
|
3PST-2NC/1NO
|
-
|
-
|
-
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x2
|
-
|
CE
|
|
|
|
SSSE
|
Active
|
Bulk
|
Trapped Key
|
3PST-2NC/1NO
|
-
|
-
|
-
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x2
|
-
|
CE
|
|
|
|
SSSE
|
Active
|
Bulk
|
Trapped Key
|
3PST-2NC/1NO
|
-
|
-
|
-
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x2
|
-
|
CE
|
|
|
|
SSSE
|
Active
|
Bulk
|
Trapped Key
|
3PST-2NC/1NO
|
-
|
-
|
-
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x2
|
-
|
CE
|
|
|
|
SSSE
|
Active
|
Bulk
|
Trapped Key
|
3PST-2NC/1NO
|
-
|
-
|
-
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x2
|
-
|
CE
|
|
|
|
SSSE
|
Active
|
Bulk
|
Trapped Key
|
3PST-2NC/1NO
|
-
|
-
|
-
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x2
|
-
|
CE
|
|
|
|
SSSE
|
Active
|
Bulk
|
Trapped Key
|
3PST-2NC/1NO
|
-
|
-
|
-
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x2
|
-
|
CE
|
|
|
|
SSSE
|
Active
|
Bulk
|
Trapped Key
|
3PST-2NC/1NO
|
-
|
-
|
-
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x2
|
-
|
CE
|
|
|
|
SSSE
|
Active
|
Bulk
|
Trapped Key
|
3PST-2NC/1NO
|
-
|
-
|
-
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x2
|
-
|
CE
|
|
|
|
SSSE
|
Active
|
Bulk
|
Trapped Key
|
3PST-2NC/1NO
|
-
|
-
|
-
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x2
|
-
|
CE
|
|
|
|
SSSE
|
Active
|
Bulk
|
Trapped Key
|
3PST-2NC/1NO
|
-
|
-
|
-
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x2
|
-
|
CE
|
|
|
|
SSSE
|
Active
|
Bulk
|
Trapped Key
|
3PST-2NC/1NO
|
-
|
-
|
-
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x2
|
-
|
CE
|
|
|
|
SSSE
|
Active
|
Bulk
|
Trapped Key
|
3PST-2NC/1NO
|
-
|
-
|
-
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x2
|
-
|
CE
|
|
|
|
SSSE
|
Active
|
Bulk
|
Trapped Key
|
3PST-2NC/1NO
|
-
|
-
|
-
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x2
|
-
|
CE
|
|
|
|
SSSE
|
Active
|
Bulk
|
Trapped Key
|
3PST-2NC/1NO
|
-
|
-
|
-
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x2
|
-
|
CE
|
|
|
|
SSSE
|
Active
|
Bulk
|
Trapped Key
|
3PST-2NC/1NO
|
-
|
-
|
-
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x2
|
-
|
CE
|
|
|
|
SSSE
|
Active
|
Bulk
|
Trapped Key
|
3PST-2NC/1NO
|
-
|
-
|
-
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x2
|
-
|
CE
|
|
|
|
SSSE
|
Active
|
Bulk
|
Trapped Key
|
3PST-2NC/1NO
|
-
|
-
|
-
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x2
|
-
|
CE
|
|
|
|
SSSE
|
Active
|
Bulk
|
Trapped Key
|
3PST-2NC/1NO
|
-
|
-
|
-
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x2
|
-
|
CE
|
|
|
|
SSSE
|
Active
|
Bulk
|
Trapped Key
|
3PST-2NC/1NO
|
-
|
-
|
-
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x2
|
-
|
CE
|
|
|
|
SSSE
|
Active
|
Bulk
|
Trapped Key
|
3PST-2NC/1NO
|
-
|
-
|
-
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x2
|
-
|
CE
|
|
|
|
SSSE
|
Active
|
Bulk
|
Trapped Key
|
3PST-2NC/1NO
|
-
|
-
|
-
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x2
|
-
|
CE
|
|
|
|
SSSE
|
Active
|
Bulk
|
Trapped Key
|
3PST-2NC/1NO
|
-
|
-
|
-
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x2
|
-
|
CE
|
|
|
|
SSSE
|
Active
|
Bulk
|
Trapped Key
|
3PST-2NC/1NO
|
-
|
-
|
-
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x2
|
-
|
CE
|
|
|
|
SSSE
|
Active
|
Bulk
|
Trapped Key
|
3PST-2NC/1NO
|
-
|
-
|
-
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x2
|
-
|
CE
|
|
|
|
SSSE
|
Active
|
Bulk
|
Trapped Key
|
3PST-2NC/1NO
|
-
|
-
|
-
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x2
|
-
|
CE
|
|
|
|
SSLE
|
Active
|
Bulk
|
Trapped Key
|
-
|
-
|
-
|
-
|
204kgf
|
Panel Disconnect
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
SSLE
|
Active
|
Bulk
|
Trapped Key
|
-
|
-
|
-
|
-
|
204kgf
|
Panel Disconnect
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
SSLE
|
Active
|
Bulk
|
Trapped Key
|
-
|
-
|
-
|
-
|
204kgf
|
Panel Disconnect
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
SSLE
|
Active
|
Bulk
|
Trapped Key
|
-
|
-
|
-
|
-
|
204kgf
|
Panel Disconnect
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
SSLE
|
Active
|
Bulk
|
Trapped Key
|
-
|
-
|
-
|
-
|
204kgf
|
Panel Disconnect
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
SSLE
|
Active
|
Bulk
|
Trapped Key
|
-
|
-
|
-
|
-
|
204kgf
|
Panel Disconnect
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
SSLE
|
Active
|
Bulk
|
Trapped Key
|
-
|
-
|
-
|
-
|
204kgf
|
Panel Disconnect
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
SSLE
|
Active
|
Bulk
|
Trapped Key
|
-
|
-
|
-
|
-
|
204kgf
|
Panel Disconnect
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
SSLE
|
Active
|
Bulk
|
Trapped Key
|
-
|
-
|
-
|
-
|
204kgf
|
Panel Disconnect
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
SSLE
|
Active
|
Bulk
|
Trapped Key
|
-
|
-
|
-
|
-
|
204kgf
|
Panel Disconnect
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
SSLE
|
Active
|
Bulk
|
Trapped Key
|
-
|
-
|
-
|
-
|
204kgf
|
Panel Disconnect
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
SSLE
|
Active
|
Bulk
|
Trapped Key
|
-
|
-
|
-
|
-
|
204kgf
|
Panel Disconnect
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
SSLE
|
Active
|
Bulk
|
Trapped Key
|
-
|
-
|
-
|
-
|
204kgf
|
Panel Disconnect
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
SSLE
|
Active
|
Bulk
|
Trapped Key
|
-
|
-
|
-
|
-
|
204kgf
|
Panel Disconnect
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
SSLE
|
Active
|
Bulk
|
Trapped Key
|
-
|
-
|
-
|
-
|
204kgf
|
Panel Disconnect
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
SSLE
|
Active
|
Bulk
|
Trapped Key
|
-
|
-
|
-
|
-
|
204kgf
|
Panel Disconnect
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
SSLE
|
Active
|
Bulk
|
Trapped Key
|
-
|
-
|
-
|
-
|
204kgf
|
Panel Disconnect
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
SSLE
|
Active
|
Bulk
|
Trapped Key
|
-
|
-
|
-
|
-
|
204kgf
|
Panel Disconnect
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
SSLE
|
Active
|
Bulk
|
Trapped Key
|
-
|
-
|
-
|
-
|
204kgf
|
Panel Disconnect
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
SSLE
|
Active
|
Bulk
|
Trapped Key
|
-
|
-
|
-
|
-
|
204kgf
|
Panel Disconnect
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
SSLE
|
Active
|
Bulk
|
Trapped Key
|
-
|
-
|
-
|
-
|
204kgf
|
Panel Disconnect
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
SSLE
|
Active
|
Bulk
|
Trapped Key
|
-
|
-
|
-
|
-
|
204kgf
|
Panel Disconnect
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
SSLE
|
Active
|
Bulk
|
Trapped Key
|
-
|
-
|
-
|
-
|
204kgf
|
Panel Disconnect
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
SSLE
|
Active
|
Bulk
|
Trapped Key
|
-
|
-
|
-
|
-
|
204kgf
|
Panel Disconnect
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
SSLE
|
Active
|
Bulk
|
Trapped Key
|
-
|
-
|
-
|
-
|
204kgf
|
Panel Disconnect
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
SSLE
|
Active
|
Bulk
|
Trapped Key
|
-
|
-
|
-
|
-
|
204kgf
|
Panel Disconnect
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
SSLE
|
Active
|
Bulk
|
Trapped Key
|
-
|
-
|
-
|
-
|
204kgf
|
Panel Disconnect
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
SSLE
|
Active
|
Bulk
|
Trapped Key
|
-
|
-
|
-
|
-
|
204kgf
|
Panel Disconnect
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
SSLE
|
Active
|
Bulk
|
Trapped Key
|
-
|
-
|
-
|
-
|
204kgf
|
Panel Disconnect
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
SSLE
|
Active
|
Bulk
|
Trapped Key
|
-
|
-
|
-
|
-
|
204kgf
|
Panel Disconnect
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
SSLE
|
Active
|
Bulk
|
Trapped Key
|
-
|
-
|
-
|
-
|
204kgf
|
Panel Disconnect
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
SSLE
|
Active
|
Bulk
|
Trapped Key
|
-
|
-
|
-
|
-
|
204kgf
|
Panel Disconnect
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
-
|
Obsolete
|
Bulk
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
|
|
|
SMS
|
Obsolete
|
Box
|
Magnetic
|
DPST-NO
|
100mA (AC), 250mA (DC)
|
-
|
120VAC, 50VDC
|
-
|
Non-Contact
|
Cable with Connector (M12)
|
-
|
20mm
|
22mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, UL
|
|
|
|
-
|
Obsolete
|
Bulk
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
|
|
|
-
|
Obsolete
|
Bulk
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
|
|
|
-
|
Obsolete
|
Bulk
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
|
|
|
SMS
|
Obsolete
|
Box
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
|
|
|
SMS
|
Active
|
Box
|
Magnetic
|
SPST-NO
|
250mA (AC)
|
-
|
100VAC
|
-
|
Non-Contact
|
Wire Leads
|
-
|
16mm
|
20mm
|
-
|
IP67 - Dust Tight, Waterproof
|
-
|
|
|
|
SMS
|
Active
|
Box
|
Magnetic
|
4PST-2NO/2NC
|
250mA (AC)
|
-
|
100VAC
|
-
|
Non-Contact
|
Wire Leads
|
-
|
16mm
|
20mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE
|
|
|
|
SMS
|
Active
|
Box
|
Magnetic
|
DPST-NO/NC
|
250mA (AC)
|
-
|
100VAC
|
-
|
Non-Contact
|
Wire Leads
|
-
|
15mm
|
20mm
|
-
|
IP67 - Dust Tight, Waterproof
|
-
|
|
|
|
-
|
Obsolete
|
Bulk
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
|
|
|
-
|
Obsolete
|
Bulk
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
|
|
|
SMS
|
Obsolete
|
Box
|
Magnetic
|
3PST-2NO/1NC
|
250mA (AC)
|
-
|
100VAC
|
-
|
Non-Contact
|
Wire Leads
|
-
|
20mm
|
22mm
|
-
|
IP67 - Dust Tight, Waterproof
|
-
|
|
|
|
SMS
|
Obsolete
|
Box
|
Magnetic
|
DPST-NO
|
250mA (AC)
|
-
|
100VAC
|
-
|
Non-Contact
|
Cable with Connector (M12)
|
-
|
20mm
|
22mm
|
-
|
IP67 - Dust Tight, Waterproof
|
-
|
|
|
|
SMS
|
Obsolete
|
Box
|
Magnetic
|
DPST-NO
|
250mA (AC)
|
-
|
100VAC
|
-
|
Non-Contact
|
Wire Leads
|
-
|
20mm
|
22mm
|
-
|
IP67 - Dust Tight, Waterproof
|
-
|
|
|
|
SMS
|
Obsolete
|
Box
|
Magnetic
|
DPST-NO/NC
|
100mA (AC), 250mA (DC)
|
-
|
120VAC, 50VDC
|
-
|
Non-Contact
|
Wire Leads
|
-
|
20mm
|
30mm
|
-
|
IP67 - Dust Tight, Waterproof
|
-
|
|
|
|
SMS
|
Obsolete
|
Box
|
Magnetic
|
DPST-NO/NC
|
100mA (AC), 250mA (DC)
|
-
|
120VAC, 50VDC
|
-
|
Non-Contact
|
Wire Leads
|
Status Indicator
|
20mm
|
30mm
|
-
|
IP67 - Dust Tight, Waterproof
|
-
|
|
|
|
SMS
|
Obsolete
|
Box
|
Magnetic
|
DPST-NO/NC
|
250mA (AC)
|
-
|
100VAC
|
-
|
Non-Contact
|
Wire Leads
|
-
|
10mm
|
15mm
|
-
|
IP67 - Dust Tight, Waterproof
|
-
|
|
|
|
SMS
|
Obsolete
|
Box
|
Magnetic
|
DPST-NO/NC
|
250mA (AC)
|
-
|
100VAC
|
-
|
Non-Contact
|
Wire Leads
|
-
|
10mm
|
15mm
|
-
|
IP67 - Dust Tight, Waterproof
|
-
|
|
|
|
SI-RF
|
Active
|
Bulk
|
RFID
|
-
|
100mA (DC)
|
24VDC
|
24VDC
|
-
|
Non-Contact
|
Cable with Connector (M12)
|
Automatic Reset
|
10mm
|
25mm
|
-
|
IP69K - Dust Tight, High Temp Water Jets, Waterproof
|
CE, cULus
|
|
|
|
SI-RF
|
Active
|
Bulk
|
RFID
|
-
|
100mA (DC)
|
24VDC
|
24VDC
|
-
|
Non-Contact
|
Cable with Connector (M12)
|
Automatic Reset
|
10mm
|
25mm
|
-
|
IP69K - Dust Tight, High Temp Water Jets, Waterproof
|
CE, cULus
|
|
|
|
SI-RF
|
Active
|
Bulk
|
RFID
|
-
|
100mA (DC)
|
24VDC
|
24VDC
|
-
|
Non-Contact
|
Cable with Connector (M12)
|
Automatic Reset
|
10mm
|
25mm
|
-
|
IP69K - Dust Tight, High Temp Water Jets, Waterproof
|
CE, cULus
|
|
|
|
SI-RF
|
Active
|
Bulk
|
RFID
|
-
|
100mA (DC)
|
24VDC
|
24VDC
|
-
|
Non-Contact
|
Cable with Connector (M12)
|
Manual Reset
|
10mm
|
25mm
|
-
|
IP69K - Dust Tight, High Temp Water Jets, Waterproof
|
CE, cULus
|
|
|
|
SI-RF
|
Active
|
Bulk
|
RFID
|
-
|
100mA (DC)
|
24VDC
|
24VDC
|
-
|
Non-Contact
|
Cable with Connector (M12)
|
Manual Reset
|
10mm
|
25mm
|
-
|
IP69K - Dust Tight, High Temp Water Jets, Waterproof
|
CE, cULus
|
|
|
|
SI-RF
|
Active
|
Bulk
|
RFID
|
-
|
100mA (DC)
|
24VDC
|
24VDC
|
-
|
Non-Contact
|
Cable with Connector (M12)
|
Automatic Reset
|
10mm
|
25mm
|
-
|
IP69K - Dust Tight, High Temp Water Jets, Waterproof
|
CE, cULus
|
|
|
|
SI-RF
|
Active
|
Bulk
|
RFID
|
-
|
100mA (DC)
|
24VDC
|
24VDC
|
-
|
Non-Contact
|
Cable with Connector (M12)
|
Automatic Reset
|
10mm
|
25mm
|
-
|
IP69K - Dust Tight, High Temp Water Jets, Waterproof
|
CE, cULus
|
|
|
|
SI-RF
|
Active
|
Bulk
|
RFID
|
-
|
100mA (DC)
|
24VDC
|
24VDC
|
-
|
Non-Contact
|
Cable Leads
|
Automatic Reset
|
10mm
|
25mm
|
-
|
IP69K - Dust Tight, High Temp Water Jets, Waterproof
|
CE, cULus
|
|
|
|
SI-RF
|
Active
|
Bulk
|
RFID
|
-
|
100mA (DC)
|
24VDC
|
24VDC
|
-
|
Non-Contact
|
Cable with Connector (M12)
|
Automatic Reset
|
10mm
|
25mm
|
-
|
IP69K - Dust Tight, High Temp Water Jets, Waterproof
|
CE, cULus
|
|
|
|
SI-RF
|
Active
|
Bulk
|
RFID
|
-
|
100mA (DC)
|
24VDC
|
24VDC
|
-
|
Non-Contact
|
Cable with Connector (M12)
|
Automatic Reset
|
10mm
|
25mm
|
-
|
IP69K - Dust Tight, High Temp Water Jets, Waterproof
|
CE, cULus
|
|
|
|
SI-RF
|
Active
|
Bulk
|
RFID
|
-
|
100mA (DC)
|
24VDC
|
24VDC
|
-
|
Non-Contact
|
Cable with Connector (M12)
|
Automatic Reset
|
10mm
|
25mm
|
-
|
IP69K - Dust Tight, High Temp Water Jets, Waterproof
|
CE, cULus
|
|
|
|
SI-RF
|
Active
|
Bulk
|
RFID
|
-
|
100mA (DC)
|
24VDC
|
24VDC
|
-
|
Non-Contact
|
Cable with Connector (M12)
|
Automatic Reset
|
10mm
|
25mm
|
-
|
IP69K - Dust Tight, High Temp Water Jets, Waterproof
|
CE, cULus
|
|
|
|
SI-RF
|
Active
|
Bulk
|
RFID
|
-
|
100mA (DC)
|
24VDC
|
24VDC
|
-
|
Non-Contact
|
Cable with Connector (M12)
|
Manual Reset
|
10mm
|
25mm
|
-
|
IP69K - Dust Tight, High Temp Water Jets, Waterproof
|
CE, cULus
|
|
|
|
SI-QS90
|
Active
|
Box
|
Non-Locking
|
3PST-2NC/1NO
|
10A (AC), 6A (DC)
|
110VAC, 24VDC
|
-
|
-
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP65 - Dust Tight, Water Resistant
|
CE, CSA, UL
|
|
|
|
SI-QS90
|
Active
|
Box
|
Non-Locking
|
DPST-NC
|
10A (AC), 6A (DC)
|
110VAC, 24VDC
|
-
|
-
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP65 - Dust Tight, Water Resistant
|
CE, CSA, UL
|
|
|
|
SI-QS90
|
Active
|
Box
|
Non-Locking
|
DPST-NC
|
10A (AC), 6A (DC)
|
110VAC, 24VDC
|
-
|
-
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP65 - Dust Tight, Water Resistant
|
CE, CSA, UL
|
|
|
|
SI-QS90
|
Active
|
Box
|
Non-Locking
|
DPST-NO/NC
|
10A (AC), 6A (DC)
|
110VAC, 24VDC
|
-
|
-
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP65 - Dust Tight, Water Resistant
|
CE, CSA, UL
|
|
|
|
SI-QM100
|
Obsolete
|
Box
|
Solenoid Release
|
DPST-NO/NC + DPST-NC
|
4A (DC)
|
24VDC
|
24VDC
|
102kgf
|
Panel Disconnect
|
Screw Terminal
|
Manual Override
|
-
|
-
|
M20 x2
|
IP67 - Dust Tight, Waterproof
|
CE, CSA, UL
|
|
|
|
SI-QM100
|
Obsolete
|
Box
|
Solenoid Release
|
DPST-NO/NC x 2
|
4A (DC)
|
24VDC
|
24VDC
|
102kgf
|
Panel Disconnect
|
Screw Terminal
|
Manual Override
|
-
|
-
|
M20 x2
|
IP67 - Dust Tight, Waterproof
|
CE, CSA, UL
|
|
|
|
SI-QM100
|
Obsolete
|
Box
|
Solenoid Release
|
DPST-NO/NC + DPST-NC
|
4A (DC)
|
24VDC
|
24VDC
|
102kgf
|
Panel Disconnect
|
Screw Terminal
|
Manual Override
|
-
|
-
|
M20 x2
|
IP67 - Dust Tight, Waterproof
|
CE, CSA, UL
|
|
|
|
SI-QM100
|
Obsolete
|
Box
|
Solenoid Release
|
DPST-NO/NC x 2
|
4A (DC)
|
24VDC
|
24VDC
|
102kgf
|
Panel Disconnect
|
Screw Terminal
|
Manual Override
|
-
|
-
|
M20 x2
|
IP67 - Dust Tight, Waterproof
|
CE, CSA, UL
|
|
|
|
SI-QM100
|
Obsolete
|
Box
|
Solenoid Release
|
DPST-NO/NC x 2
|
4A (AC)
|
120VAC
|
120VAC
|
102kgf
|
Panel Disconnect
|
Screw Terminal
|
Manual Override
|
-
|
-
|
M20 x2
|
IP67 - Dust Tight, Waterproof
|
CE, CSA, UL
|
|
|
|
SI-QM100
|
Obsolete
|
Box
|
Solenoid Locking
|
DPST-NO/NC x 2
|
4A (AC)
|
120VAC
|
120VAC
|
102kgf
|
Panel Disconnect
|
Screw Terminal
|
Manual Override
|
-
|
-
|
M20 x2
|
IP67 - Dust Tight, Waterproof
|
CE, CSA, UL
|
|
|
|
SI-LS83
|
Active
|
Bulk
|
Non-Locking
|
DPST-NC
|
10A (AC), 6A (DC)
|
110VAC, 24VDC
|
-
|
-
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M16
|
IP65 - Dust Tight, Water Resistant
|
CE, CSA, UL
|
|
|
|
SI-LS83
|
Active
|
Bulk
|
Non-Locking
|
DPST-NO/NC
|
10A (AC), 6A (DC)
|
110VAC, 24VDC
|
-
|
-
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M16
|
IP65 - Dust Tight, Water Resistant
|
CE, CSA, UL
|
|
|
|
SI-LS83
|
Active
|
Bulk
|
Non-Locking
|
DPST-NC
|
10A (AC), 6A (DC)
|
110VAC, 24VDC
|
-
|
-
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M16
|
IP65 - Dust Tight, Water Resistant
|
CE, CSA, UL
|
|
|
|
SI-LS83
|
Active
|
Box
|
-
|
DPST-NO
|
10A (AC), 6A (DC)
|
100VAC, 24VDC
|
-
|
-
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20
|
IP65 - Dust Tight, Water Resistant
|
CE, CSA, UL
|
|
|
|
SI-LS83
|
Active
|
Bulk
|
Non-Locking
|
DPST-NO/NC
|
10A (AC), 6A (DC)
|
110VAC, 24VDC
|
-
|
-
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M16
|
IP65 - Dust Tight, Water Resistant
|
CE, CSA, UL
|
|
|
|
SI-LS42
|
Active
|
Bulk
|
Solenoid Release
|
DPST-NO/NC + DPST-NC
|
1A (AC)
|
24VAC
|
110/230VAC
|
153kgf
|
Panel Disconnect
|
Screw Terminal
|
Manual Override
|
-
|
-
|
M20
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
SI-LS42
|
Active
|
Bulk
|
Solenoid Release
|
DPST-NO/NC x 2
|
1A (AC)
|
24VAC
|
110/230VAC
|
153kgf
|
Panel Disconnect
|
Screw Terminal
|
Manual Override
|
-
|
-
|
M20
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
SI-LS42
|
Active
|
Box
|
Solenoid Release
|
3PST-2NC/1NO + SPST-NC
|
1A (AC)
|
24VAC
|
110/230VAC
|
153kgf
|
Panel Disconnect
|
Screw Terminal
|
Manual Override
|
-
|
-
|
M20
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
SI-LS42
|
Active
|
Bulk
|
Solenoid Release
|
DPST-NO/NC + DPST-NC
|
1A (AC)
|
24VAC
|
110/230VAC
|
153kgf
|
Panel Disconnect
|
Screw Terminal
|
Manual Override
|
-
|
-
|
M20
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
SI-LS42
|
Active
|
Bulk
|
Solenoid Release
|
DPST-NO/NC x 2
|
1A (AC)
|
24VAC
|
110/230VAC
|
153kgf
|
Panel Disconnect
|
Screw Terminal
|
Manual Override
|
-
|
-
|
M20
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
SI-LS42
|
Active
|
Bulk
|
Solenoid Locking
|
DPST-NO/NC x 2
|
1A (AC)
|
24VAC
|
110/230VAC
|
153kgf
|
Panel Disconnect
|
Screw Terminal
|
Manual Override
|
-
|
-
|
M20
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
SI-LS42
|
Active
|
Bulk
|
Solenoid Locking
|
3PST-2NC/1NO + SPST-NC
|
1A (AC)
|
24VAC
|
110/230VAC
|
153kgf
|
Panel Disconnect
|
Screw Terminal
|
Manual Override
|
-
|
-
|
M20
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
SI-LS42
|
Active
|
Box
|
Solenoid Locking
|
DPST-NO/NC + DPST-NC
|
1A (AC)
|
24VAC
|
110/230VAC
|
153kgf
|
Panel Disconnect
|
Screw Terminal
|
Manual Override
|
-
|
-
|
M20
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
SI-LS42
|
Active
|
Box
|
Solenoid Locking
|
DPST-NO/NC + DPST-NC
|
1A (AC)
|
24VAC
|
110/230VAC
|
153kgf
|
Panel Disconnect
|
Screw Terminal
|
Manual Override
|
-
|
-
|
M20
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
SI-LS42
|
Active
|
Bulk
|
Solenoid Locking
|
DPST-NO/NC x 2
|
1A (AC)
|
24VAC
|
110/230VAC
|
153kgf
|
Panel Disconnect
|
Screw Terminal
|
Manual Override
|
-
|
-
|
M20
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
SI-LS42
|
Active
|
Box
|
Solenoid Locking
|
DPST-NO/NC + DPST-NC
|
1A (AC)
|
24VAC
|
110/230VAC
|
153kgf
|
Panel Disconnect
|
Screw Terminal
|
Manual Override
|
-
|
-
|
M20
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
SI-LS42
|
Active
|
Bulk
|
Solenoid Locking
|
DPST-NO/NC x 2
|
1A (AC)
|
24VAC
|
110/230VAC
|
153kgf
|
Panel Disconnect
|
Screw Terminal
|
Manual Override
|
-
|
-
|
M20
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
SI-LS42
|
Active
|
Bulk
|
Solenoid Release
|
3PST-NC + SPST-NC
|
1A (AC)
|
24VAC
|
24VAC/DC
|
153kgf
|
Panel Disconnect
|
Screw Terminal
|
Manual Override
|
-
|
-
|
M20
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
SI-LS42
|
Active
|
Bulk
|
Solenoid Release
|
3PST-2NC/1NO + SPST-NC
|
1A (AC)
|
24VAC
|
24VAC/DC
|
153kgf
|
Panel Disconnect
|
Screw Terminal
|
Manual Override
|
-
|
-
|
M20
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
SI-LS42
|
Active
|
Bulk
|
Solenoid Release
|
DPST-NO/NC + DPST-NC
|
1A (AC)
|
24VAC
|
24VAC/DC
|
153kgf
|
Panel Disconnect
|
Screw Terminal
|
Manual Override
|
-
|
-
|
M20
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
SI-LS42
|
Active
|
Bulk
|
Solenoid Release
|
DPST-NO/NC x 2
|
1A (AC)
|
24VAC
|
24VAC/DC
|
153kgf
|
Panel Disconnect
|
Screw Terminal
|
Manual Override
|
-
|
-
|
M20
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
SI-LS42
|
Active
|
Bulk
|
Solenoid Locking
|
3PST-2NC/1NO + SPST-NC
|
1A (AC)
|
24VAC
|
24VAC/DC
|
153kgf
|
Panel Disconnect
|
Screw Terminal
|
Manual Override
|
-
|
-
|
M20
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
SI-LS42
|
Active
|
Bulk
|
Solenoid Release
|
3PST-2NC/1NO + SPST-NC
|
1A (AC)
|
24VAC
|
24VAC/DC
|
153kgf
|
Panel Disconnect
|
Screw Terminal
|
Manual Override
|
-
|
-
|
M20
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
SI-LS42
|
Active
|
Bulk
|
Solenoid Release
|
DPST-NO/NC + DPST-NC
|
1A (AC)
|
24VAC
|
24VAC/DC
|
153kgf
|
Panel Disconnect
|
Screw Terminal
|
Manual Override
|
-
|
-
|
M20
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
SI-LS42
|
Active
|
Bulk
|
Solenoid Release
|
DPST-NO/NC + DPST-NC
|
1A (AC)
|
24VAC
|
24VAC/DC
|
153kgf
|
Panel Disconnect
|
Screw Terminal
|
Manual Override
|
-
|
-
|
M20
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
SI-LS42
|
Active
|
Bulk
|
Solenoid Release
|
DPST-NO/NC x 2
|
1A (AC)
|
24VAC
|
24VAC/DC
|
153kgf
|
Panel Disconnect
|
Screw Terminal
|
Manual Override
|
-
|
-
|
M20
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
SI-LS42
|
Active
|
Bulk
|
Solenoid Release
|
DPST-NO/NC x 2
|
1A (AC)
|
24VAC
|
24VAC/DC
|
153kgf
|
Panel Disconnect
|
Screw Terminal
|
Manual Override
|
-
|
-
|
M20
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
SI-LS42
|
Active
|
Bulk
|
Solenoid Locking
|
3PST-NC + SPST-NC
|
1A (AC)
|
24VAC
|
24VAC/DC
|
153kgf
|
Panel Disconnect
|
Screw Terminal
|
Manual Override
|
-
|
-
|
M20
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
SI-LS42
|
Active
|
Box
|
Solenoid Locking
|
3PST-NC + SPST-NC
|
1A (AC)
|
24VAC
|
24VAC/DC
|
153kgf
|
Panel Disconnect
|
Screw Terminal
|
Manual Override
|
-
|
-
|
M20
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
SI-LS42
|
Active
|
Bulk
|
Solenoid Locking
|
3PST-2NC/1NO + SPST-NC
|
1A (AC)
|
24VAC
|
24VAC/DC
|
153kgf
|
Panel Disconnect
|
Screw Terminal
|
Manual Override
|
-
|
-
|
M20
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
SI-LS42
|
Active
|
Bulk
|
Solenoid Locking
|
3PST-2NC/1NO + SPST-NC
|
1A (AC)
|
24VAC
|
24VAC/DC
|
153kgf
|
Panel Disconnect
|
Screw Terminal
|
Manual Override
|
-
|
-
|
M20
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
SI-LS42
|
Active
|
Bulk
|
Solenoid Locking
|
DPST-NO/NC + DPST-NC
|
1A (AC)
|
24VAC
|
24VAC/DC
|
153kgf
|
Panel Disconnect
|
Screw Terminal
|
Manual Override
|
-
|
-
|
M20
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
SI-LS42
|
Active
|
Bulk
|
Solenoid Locking
|
DPST-NO/NC + DPST-NC
|
1A (AC)
|
24VAC
|
24VAC/DC
|
153kgf
|
Panel Disconnect
|
Screw Terminal
|
Manual Override
|
-
|
-
|
M20
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
SI-LS42
|
Active
|
Bulk
|
Solenoid Locking
|
DPST-NO/NC x 2
|
1A (AC)
|
24VAC
|
24VAC/DC
|
153kgf
|
Panel Disconnect
|
Screw Terminal
|
Manual Override
|
-
|
-
|
M20
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
SI-LS42
|
Active
|
Bulk
|
Solenoid Locking
|
DPST-NO/NC x 2
|
1A (AC)
|
24VAC
|
24VAC/DC
|
153kgf
|
Panel Disconnect
|
Screw Terminal
|
Manual Override
|
-
|
-
|
M20
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
SI-LS42
|
Active
|
Bulk
|
Solenoid Locking
|
3PST-NC + SPST-NC
|
1A (AC)
|
24VAC
|
24VAC/DC
|
153kgf
|
Panel Disconnect
|
Screw Terminal
|
Manual Override
|
-
|
-
|
M20
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
SI-LS42
|
Active
|
Bulk
|
Solenoid Locking
|
3PST-2NC/1NO + SPST-NC
|
1A (AC)
|
24VAC
|
24VAC/DC
|
153kgf
|
Panel Disconnect
|
Screw Terminal
|
Manual Override
|
-
|
-
|
M20
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
SI-LS42
|
Active
|
Bulk
|
Solenoid Locking
|
DPST-NO/NC + DPST-NC
|
1A (AC)
|
24VAC
|
24VAC/DC
|
153kgf
|
Panel Disconnect
|
Screw Terminal
|
Manual Override
|
-
|
-
|
M20
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
SI-LS42
|
Active
|
Bulk
|
Solenoid Locking
|
DPST-NO/NC x 2
|
1A (AC)
|
24VAC
|
24VAC/DC
|
153kgf
|
Panel Disconnect
|
Screw Terminal
|
Manual Override
|
-
|
-
|
M20
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
SI-LS31
|
Active
|
Bulk
|
Hinge
|
DPST-NC
|
10A (AC), 6A (DC)
|
110VAC, 24VDC
|
-
|
-
|
Shaft
|
Screw Terminal
|
-
|
-
|
-
|
M20
|
IP65 - Dust Tight, Water Resistant
|
CE, CSA, UL
|
|
|
|
SI-LS31
|
Active
|
Bulk
|
Hinge
|
DPST-NO/NC
|
10A (AC), 6A (DC)
|
110VAC, 24VDC
|
-
|
-
|
Shaft
|
Screw Terminal
|
-
|
-
|
-
|
M20
|
IP65 - Dust Tight, Water Resistant
|
CE, CSA, UL
|
|
|
|
SI-LS31H
|
Active
|
Box
|
Hinge
|
DPST-NC
|
10A (AC), 6A (DC)
|
110VAC, 24VDC
|
-
|
-
|
Arm Lever
|
Screw Terminal
|
-
|
-
|
-
|
M20
|
IP65 - Dust Tight, Water Resistant
|
CE, CSA, UL
|
|
|
|
SI-LS31H
|
Active
|
Box
|
Hinge
|
DPST-NO/NC
|
10A (AC), 6A (DC)
|
110VAC, 24VDC
|
-
|
-
|
Arm Lever
|
Screw Terminal
|
-
|
-
|
-
|
M20
|
IP65 - Dust Tight, Water Resistant
|
CE, CSA, UL
|
|
|
|
SI-LS31H
|
Active
|
Box
|
Hinge
|
DPST-NC
|
10A (AC), 6A (DC)
|
110VAC, 24VDC
|
-
|
-
|
Arm Lever
|
Screw Terminal
|
-
|
-
|
-
|
M20
|
IP65 - Dust Tight, Water Resistant
|
CE, CSA, UL
|
|
|
|
SI-LS31H
|
Active
|
Box
|
Hinge
|
DPST-NC
|
10A (AC), 6A (DC)
|
110VAC, 24VDC
|
-
|
-
|
Arm Lever
|
Screw Terminal
|
-
|
-
|
-
|
M20
|
IP65 - Dust Tight, Water Resistant
|
CE, CSA, UL
|
|
|
|
SI-LS31H
|
Active
|
Box
|
Hinge
|
DPST-NO/NC
|
10A (AC), 6A (DC)
|
110VAC, 24VDC
|
-
|
-
|
Arm Lever
|
Screw Terminal
|
-
|
-
|
-
|
M20
|
IP65 - Dust Tight, Water Resistant
|
CE, CSA, UL
|
|
|
|
SI-LS100
|
Active
|
Bulk
|
Non-Locking
|
3PST-2NC/1NO
|
10A (AC), 6A (DC)
|
110VAC, 24VDC
|
-
|
-
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20
|
IP65 - Dust Tight, Water Resistant
|
CE, CSA, UL
|
|
|
|
SI-LS100
|
Active
|
Bulk
|
Non-Locking
|
3PST-2NC/1NO
|
10A (AC), 6A (DC)
|
110VAC, 24VDC
|
-
|
-
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20
|
IP65 - Dust Tight, Water Resistant
|
CE, CSA, UL
|
|
|
|
SI-LS100
|
Active
|
Bulk
|
Non-Locking
|
3PST-2NC/1NO
|
10A (AC), 6A (DC)
|
110VAC, 24VDC
|
-
|
-
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20
|
IP65 - Dust Tight, Water Resistant
|
CE, CSA, UL
|
|
|
|
SI-LS100
|
Active
|
Bulk
|
Non-Locking
|
3PST-2NC/1NO
|
10A (AC), 6A (DC)
|
110VAC, 24VDC
|
-
|
-
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20
|
IP65 - Dust Tight, Water Resistant
|
CE, CSA, UL
|
|
|
|
SI-LM40
|
Active
|
Bulk
|
Non-Locking
|
DPST-NC
|
10A (AC), 6A (DC)
|
110VAC, 24VDC
|
-
|
2kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20
|
IP65 - Dust Tight, Water Resistant
|
CE, CSA, UL
|
|
|
|
SI-LM40
|
Active
|
Bulk
|
Non-Locking
|
DPST-NO/NC
|
10A (AC), 6A (DC)
|
110VAC, 24VDC
|
-
|
2kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20
|
IP65 - Dust Tight, Water Resistant
|
CE, CSA, UL
|
|
|
|
SI-LM40KH
|
Active
|
Bulk
|
Non-Locking
|
3PST-2NC/1NO
|
10A (AC), 6A (DC)
|
110VAC, 24VDC
|
-
|
-
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20
|
IP65 - Dust Tight, Water Resistant
|
CE, CSA, UL
|
|
|
|
SI-LM40KH
|
Active
|
Bulk
|
Non-Locking
|
DPST-NC
|
10A (AC), 6A (DC)
|
110VAC, 24VDC
|
-
|
-
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20
|
IP65 - Dust Tight, Water Resistant
|
CE, CSA, UL
|
|
|
|
SI-LM40KH
|
Active
|
Bulk
|
Non-Locking
|
3PST-2NC/1NO
|
10A (AC), 6A (DC)
|
110VAC, 24VDC
|
-
|
-
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20
|
IP65 - Dust Tight, Water Resistant
|
CE, CSA, UL
|
|
|
|
SI-LM40KH
|
Active
|
Bulk
|
Non-Locking
|
DPST-NC
|
10A (AC), 6A (DC)
|
110VAC, 24VDC
|
-
|
-
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20
|
IP65 - Dust Tight, Water Resistant
|
CE, CSA, UL
|
|
|
|
SI-LM40KH
|
Active
|
Bulk
|
Non-Locking
|
DPST-NO/NC
|
10A (AC), 6A (DC)
|
110VAC, 24VDC
|
-
|
-
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20
|
IP65 - Dust Tight, Water Resistant
|
CE, CSA, UL
|
|
|
|
SI-LM40
|
Active
|
Bulk
|
Non-Locking
|
DPST-NC
|
10A (AC), 6A (DC)
|
110VAC, 24VDC
|
-
|
2kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20
|
IP65 - Dust Tight, Water Resistant
|
CE, CSA, UL
|
|
|
|
SI-LM40
|
Active
|
Bulk
|
Non-Locking
|
DPST-NO/NC
|
10A (AC), 6A (DC)
|
110VAC, 24VDC
|
-
|
2kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20
|
IP65 - Dust Tight, Water Resistant
|
CE, CSA, UL
|
|
|
|
SI-LM40KH
|
Active
|
Bulk
|
Non-Locking
|
3PST-2NC/1NO
|
10A (AC), 6A (DC)
|
110VAC, 24VDC
|
-
|
-
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20
|
IP65 - Dust Tight, Water Resistant
|
CE, CSA, UL
|
|
|
|
SI-LM40KH
|
Active
|
Bulk
|
Non-Locking
|
DPST-NC
|
10A (AC), 6A (DC)
|
110VAC, 24VDC
|
-
|
-
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20
|
IP65 - Dust Tight, Water Resistant
|
CE, CSA, UL
|
|
|
|
SI-LM40KH
|
Active
|
Bulk
|
Non-Locking
|
DPST-NO/NC
|
10A (AC), 6A (DC)
|
110VAC, 24VDC
|
-
|
-
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20
|
IP65 - Dust Tight, Water Resistant
|
CE, CSA, UL
|
|
|
|
SG-B2
|
Active
|
Bulk
|
Key Locking
|
DPST-NC
|
2.5A (AC/DC)
|
125VAC, 30VDC
|
-
|
-
|
Panel Disconnect
|
Cable Leads
|
Manual Override
|
-
|
-
|
-
|
IP65 - Dust Tight, Water Resistant
|
CE, cURus, TUV
|
|
|
|
SG-B2
|
Active
|
Bulk
|
Key Locking
|
DPST-NC
|
2.5A (AC/DC)
|
125VAC, 30VDC
|
-
|
-
|
Panel Disconnect
|
Cable Leads
|
-
|
-
|
-
|
-
|
IP65 - Dust Tight, Water Resistant
|
CE, cURus, TUV
|
|
|
|
SG-B2
|
Active
|
Bulk
|
Key Locking
|
DPST-NO/NC
|
2.5A (AC/DC)
|
125VAC, 30VDC
|
-
|
-
|
Panel Disconnect
|
Cable Leads
|
-
|
-
|
-
|
-
|
IP65 - Dust Tight, Water Resistant
|
CE, cURus, TUV
|
|
|
|
SG-B2
|
Active
|
Bulk
|
Key Locking
|
DPST-NC
|
2.5A (AC/DC)
|
125VAC, 30VDC
|
-
|
-
|
Panel Disconnect
|
Cable Leads
|
Manual Override
|
-
|
-
|
-
|
IP65 - Dust Tight, Water Resistant
|
CE, cURus, TUV
|
|
|
|
SG-B2
|
Active
|
Bulk
|
Key Locking
|
DPST-NC
|
2.5A (AC/DC)
|
125VAC, 30VDC
|
-
|
-
|
Panel Disconnect
|
Cable Leads
|
-
|
-
|
-
|
-
|
IP65 - Dust Tight, Water Resistant
|
CE, cURus, TUV
|
|
|
|
SG-B2
|
Active
|
Bulk
|
Key Locking
|
DPST-NO/NC
|
2.5A (AC/DC)
|
125VAC, 30VDC
|
-
|
-
|
Panel Disconnect
|
Cable Leads
|
-
|
-
|
-
|
-
|
IP65 - Dust Tight, Water Resistant
|
CE, cURus, TUV
|
|
|
|
SG-B2
|
Active
|
Bulk
|
Key Locking
|
DPST-NC
|
2.5A (AC/DC)
|
125VAC, 30VDC
|
-
|
-
|
Panel Disconnect
|
Cable Leads
|
Manual Override
|
-
|
-
|
-
|
IP65 - Dust Tight, Water Resistant
|
CE, cURus, TUV
|
|
|
|
SG-B2
|
Active
|
Bulk
|
Key Locking
|
DPST-NC
|
2.5A (AC/DC)
|
125VAC, 30VDC
|
-
|
-
|
Panel Disconnect
|
Cable Leads
|
-
|
-
|
-
|
-
|
IP65 - Dust Tight, Water Resistant
|
CE, cURus, TUV
|
|
|
|
SG-B2
|
Active
|
Bulk
|
Key Locking
|
DPST-NO/NC
|
2.5A (AC/DC)
|
125VAC, 30VDC
|
-
|
-
|
Panel Disconnect
|
Cable Leads
|
-
|
-
|
-
|
-
|
IP65 - Dust Tight, Water Resistant
|
CE, cURus, TUV
|
|
|
|
SG-B1
|
Active
|
Bulk
|
Solenoid Locking
|
DPST-NC
|
2A (AC/DC)
|
125VAC, 30VDC
|
24VDC
|
51kgf
|
Panel Disconnect
|
Cable Leads
|
Manual Override
|
-
|
-
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus, TUV
|
|
|
|
SG-B1
|
Active
|
Bulk
|
Solenoid Locking
|
DPST-NC
|
2A (AC/DC)
|
125VAC, 30VDC
|
24VDC
|
51kgf
|
Panel Disconnect
|
Cable Leads
|
Manual Override
|
-
|
-
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus, TUV
|
|
|
|
SG-B1
|
Active
|
Bulk
|
Solenoid Locking
|
DPST-NC
|
2A (AC/DC)
|
125VAC, 30VDC
|
24VDC
|
51kgf
|
Panel Disconnect
|
Cable Leads
|
Manual Override
|
-
|
-
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus, TUV
|
|
|
|
SG-B1
|
Active
|
Bulk
|
Solenoid Locking
|
DPST-NC
|
2A (AC/DC)
|
125VAC, 30VDC
|
24VDC
|
51kgf
|
Panel Disconnect
|
Cable Leads
|
Manual Override
|
-
|
-
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus, TUV
|
|
|
|
SG-B1
|
Active
|
Bulk
|
Solenoid Release
|
DPST-NC
|
2A (AC/DC)
|
125VAC, 30VDC
|
24VDC
|
51kgf
|
Panel Disconnect
|
Cable Leads
|
Manual Override
|
-
|
-
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus, TUV
|
|
|
|
SG-B1
|
Active
|
Bulk
|
Solenoid Release
|
DPST-NC
|
2A (AC/DC)
|
125VAC, 30VDC
|
24VDC
|
51kgf
|
Panel Disconnect
|
Cable Leads
|
Manual Override
|
-
|
-
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus, TUV
|
|
|
|
SG-B1
|
Active
|
Bulk
|
Solenoid Release
|
DPST-NC
|
2A (AC/DC)
|
125VAC, 30VDC
|
24VDC
|
51kgf
|
Panel Disconnect
|
Cable Leads
|
Manual Override
|
-
|
-
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus, TUV
|
|
|
|
SG-B1
|
Active
|
Bulk
|
Solenoid Release
|
DPST-NC
|
2A (AC/DC)
|
125VAC, 30VDC
|
24VDC
|
51kgf
|
Panel Disconnect
|
Cable Leads
|
Manual Override
|
-
|
-
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus, TUV
|
|
|
|
SG-A1
|
Active
|
Bulk
|
Non-Locking
|
DPST-NC + SPST-NO
|
2.5A (AC/DC)
|
125VAC, 30VDC
|
-
|
-
|
Panel Disconnect
|
Cable Leads
|
Cable Length 5m
|
-
|
-
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus, TUV
|
|
|
|
SG-A1
|
Active
|
Bulk
|
Non-Locking
|
DPST-NC + SPST-NO
|
2.5A (AC/DC)
|
125VAC, 30VDC
|
-
|
-
|
Panel Disconnect
|
Cable Leads
|
Cable Length 1m
|
-
|
-
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus, TUV
|
|
|
|
SG-A1
|
Active
|
Bulk
|
Non-Locking
|
3PST-NC
|
2.5A (AC/DC)
|
125VAC, 30VDC
|
-
|
-
|
Panel Disconnect
|
Cable Leads
|
Cable Length 5m
|
-
|
-
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus, TUV
|
|
|
|
SG-A1
|
Active
|
Bulk
|
Non-Locking
|
3PST-NC
|
2.5A (AC/DC)
|
125VAC, 30VDC
|
-
|
-
|
Panel Disconnect
|
Cable Leads
|
Cable Length 1m
|
-
|
-
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus, TUV
|
|
|
|
SG-A1
|
Active
|
Bulk
|
Non-Locking
|
DPST-NC
|
2.5A (AC/DC)
|
125VAC, 30VDC
|
-
|
-
|
Panel Disconnect
|
Cable Leads
|
Cable Length 5m
|
-
|
-
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus, TUV
|
|
|
|
SG-A1
|
Active
|
Bulk
|
Non-Locking
|
DPST-NC
|
2.5A (AC/DC)
|
125VAC, 30VDC
|
-
|
-
|
Panel Disconnect
|
Cable Leads
|
Cable Length 1m
|
-
|
-
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus, TUV
|
|
|
|
SCL
|
Active
|
Bulk
|
Trapped Key
|
-
|
-
|
-
|
-
|
-
|
Locking Pin
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
SCL
|
Active
|
Bulk
|
Trapped Key
|
-
|
-
|
-
|
-
|
-
|
Locking Pin
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
SCL
|
Active
|
Bulk
|
Trapped Key
|
-
|
-
|
-
|
-
|
-
|
Locking Pin
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
SCL
|
Active
|
Bulk
|
Trapped Key
|
-
|
-
|
-
|
-
|
-
|
Locking Pin
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
SCL
|
Active
|
Bulk
|
Trapped Key
|
-
|
-
|
-
|
-
|
-
|
Locking Pin
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
SCL
|
Active
|
Bulk
|
Trapped Key
|
-
|
-
|
-
|
-
|
-
|
Locking Pin
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
SCL
|
Active
|
Bulk
|
Trapped Key
|
-
|
-
|
-
|
-
|
-
|
Locking Pin
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
SCL
|
Active
|
Bulk
|
Trapped Key
|
-
|
-
|
-
|
-
|
-
|
Locking Pin
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
SCL
|
Active
|
Bulk
|
Trapped Key
|
-
|
-
|
-
|
-
|
-
|
Locking Pin
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
SCL
|
Active
|
Bulk
|
Trapped Key
|
-
|
-
|
-
|
-
|
-
|
Locking Pin
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
SCL
|
Active
|
Bulk
|
Trapped Key
|
-
|
-
|
-
|
-
|
-
|
Locking Pin
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
SCL
|
Active
|
Bulk
|
Trapped Key
|
-
|
-
|
-
|
-
|
-
|
Locking Pin
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
SCL
|
Active
|
Bulk
|
Trapped Key
|
-
|
-
|
-
|
-
|
-
|
Locking Pin
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
SCL
|
Active
|
Bulk
|
Trapped Key
|
-
|
-
|
-
|
-
|
-
|
Locking Pin
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
SAL
|
Active
|
Bulk
|
Trapped Key
|
-
|
-
|
-
|
-
|
-
|
Arm Lever
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
SAL
|
Active
|
Bulk
|
Trapped Key
|
-
|
-
|
-
|
-
|
-
|
Arm Lever
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
SAL
|
Active
|
Bulk
|
Trapped Key
|
-
|
-
|
-
|
-
|
-
|
Arm Lever
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
SAL
|
Active
|
Bulk
|
Trapped Key
|
-
|
-
|
-
|
-
|
-
|
Arm Lever
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
SAL
|
Active
|
Bulk
|
Trapped Key
|
-
|
-
|
-
|
-
|
-
|
Arm Lever
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
SAL
|
Active
|
Bulk
|
Trapped Key
|
-
|
-
|
-
|
-
|
-
|
Arm Lever
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
SAL
|
Active
|
Bulk
|
Trapped Key
|
-
|
-
|
-
|
-
|
-
|
Arm Lever
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
SAL
|
Active
|
Bulk
|
Trapped Key
|
-
|
-
|
-
|
-
|
-
|
Arm Lever
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
SAL
|
Active
|
Bulk
|
Trapped Key
|
-
|
-
|
-
|
-
|
-
|
Arm Lever
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
SAL
|
Active
|
Bulk
|
Trapped Key
|
-
|
-
|
-
|
-
|
-
|
Arm Lever
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
SAL
|
Active
|
Bulk
|
Trapped Key
|
-
|
-
|
-
|
-
|
-
|
Arm Lever
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
SAL
|
Active
|
Bulk
|
Trapped Key
|
-
|
-
|
-
|
-
|
-
|
Arm Lever
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
SAL
|
Active
|
Bulk
|
Trapped Key
|
-
|
-
|
-
|
-
|
-
|
Arm Lever
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
SAL
|
Active
|
Bulk
|
Trapped Key
|
-
|
-
|
-
|
-
|
-
|
Arm Lever
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
SAL
|
Active
|
Bulk
|
Trapped Key
|
-
|
-
|
-
|
-
|
-
|
Arm Lever
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
SAL
|
Active
|
Bulk
|
Trapped Key
|
-
|
-
|
-
|
-
|
-
|
Arm Lever
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
SAL
|
Active
|
Bulk
|
Trapped Key
|
-
|
-
|
-
|
-
|
-
|
Arm Lever
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
SAL
|
Active
|
Bulk
|
Trapped Key
|
-
|
-
|
-
|
-
|
-
|
Arm Lever
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
SAL
|
Active
|
Bulk
|
Trapped Key
|
-
|
-
|
-
|
-
|
-
|
Arm Lever
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
SAL
|
Active
|
Bulk
|
Trapped Key
|
-
|
-
|
-
|
-
|
-
|
Arm Lever
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
SAL
|
Active
|
Bulk
|
Trapped Key
|
-
|
-
|
-
|
-
|
-
|
Arm Lever
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
SAL
|
Active
|
Bulk
|
Trapped Key
|
-
|
-
|
-
|
-
|
-
|
Arm Lever
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
SAL
|
Active
|
Bulk
|
Trapped Key
|
-
|
-
|
-
|
-
|
-
|
Arm Lever
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
SAL
|
Active
|
Bulk
|
Trapped Key
|
-
|
-
|
-
|
-
|
-
|
Arm Lever
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
SAL
|
Active
|
Bulk
|
Trapped Key
|
-
|
-
|
-
|
-
|
-
|
Arm Lever
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
RDI2
|
Obsolete
|
Bulk
|
Solenoid Release
|
-
|
-
|
-
|
-
|
-
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
-
|
-
|
-
|
|
|
|
RDI2
|
Obsolete
|
Bulk
|
Solenoid Release
|
-
|
-
|
-
|
-
|
-
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
-
|
-
|
-
|
|
|
|
RDI
|
Active
|
Bulk
|
Solenoid Release
|
-
|
-
|
-
|
24VAC/DC
|
608kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
-
|
-
|
ASME, UL
|
|
|
|
RDI
|
Active
|
Bulk
|
Solenoid Release
|
-
|
-
|
-
|
24VAC/DC
|
608kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
-
|
-
|
ASME, UL
|
|
|
|
RDI
|
Active
|
Bulk
|
Solenoid Release
|
-
|
-
|
-
|
24VAC/DC
|
608kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
-
|
-
|
ASME, UL
|
|
|
|
RDI
|
Active
|
Bulk
|
Solenoid Release
|
-
|
-
|
-
|
24VAC/DC
|
608kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
-
|
-
|
ASME, UL
|
|
|
|
RDI
|
Obsolete
|
Bulk
|
Solenoid Release
|
-
|
-
|
-
|
24VAC/DC
|
608kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
-
|
-
|
ASME, UL
|
|
|
|
RDI
|
Obsolete
|
Bulk
|
Solenoid Release
|
-
|
-
|
-
|
24VAC/DC
|
608kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
-
|
-
|
ASME, UL
|
|
|
|
RDI
|
Active
|
Bulk
|
Solenoid Release
|
-
|
-
|
-
|
24VAC/DC
|
608kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
-
|
-
|
ASME, UL
|
|
|
|
RDI
|
Active
|
Bulk
|
Solenoid Release
|
-
|
-
|
-
|
24VAC/DC
|
608kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
-
|
-
|
ASME, UL
|
|
|
|
RDI
|
Active
|
Bulk
|
Solenoid Release
|
-
|
-
|
-
|
24VAC/DC
|
608kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
-
|
-
|
ASME, UL
|
|
|
|
RDI
|
Active
|
Bulk
|
Solenoid Release
|
-
|
-
|
-
|
24VAC/DC
|
608kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
-
|
-
|
ASME, UL
|
|
|
|
RDI
|
Active
|
Bulk
|
Solenoid Release
|
-
|
-
|
-
|
24VAC/DC
|
608kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
-
|
-
|
ASME, UL
|
|
|
|
RDI
|
Obsolete
|
Bulk
|
Solenoid Release
|
-
|
-
|
-
|
24VAC/DC
|
608kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
-
|
-
|
ASME, UL
|
|
|
|
RDI
|
Active
|
Bulk
|
Solenoid Release
|
-
|
-
|
-
|
24VAC/DC
|
608kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
-
|
-
|
ASME, UL
|
|
|
|
RDI
|
Active
|
Bulk
|
Solenoid Release
|
-
|
-
|
-
|
24VAC/DC
|
608kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
-
|
-
|
ASME, UL
|
|
|
|
RDI
|
Obsolete
|
Bulk
|
Solenoid Release
|
-
|
-
|
-
|
24VAC/DC
|
608kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
-
|
-
|
ASME, UL
|
|
|
|
PXS
|
Active
|
Box
|
Magnetic
|
DPST-NC
|
10mA (DC)
|
24VDC
|
24VDC
|
-
|
Non-Contact
|
Cable Leads
|
Status Indicator
|
8mm
|
20mm
|
-
|
IP66/IP67 - Dust Tight, Water Resistant, Waterproof
|
CE, cURus
|
|
|
|
PXS
|
Active
|
Box
|
Magnetic
|
DPST-NC
|
10mA (DC)
|
24VDC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
8mm
|
20mm
|
-
|
IP66/IP67 - Dust Tight, Water Resistant, Waterproof
|
CE, cURus
|
|
|
|
PXS
|
Active
|
Box
|
Magnetic
|
DPST-NC
|
10mA (DC)
|
24VDC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
8mm
|
20mm
|
-
|
IP66/IP67 - Dust Tight, Water Resistant, Waterproof
|
CE, cURus
|
|
|
|
PXS
|
Active
|
Box
|
Magnetic
|
3PST-2NC/1NO
|
10mA (DC)
|
24VDC
|
24VDC
|
-
|
Non-Contact
|
Cable Leads
|
Status Indicator
|
8mm
|
20mm
|
-
|
IP66/IP67 - Dust Tight, Water Resistant, Waterproof
|
CE, cURus
|
|
|
|
PXS
|
Active
|
Box
|
Magnetic
|
DPST-NO/NC
|
100mA (DC)
|
24VDC
|
24VDC
|
-
|
Non-Contact
|
Cable Leads
|
Status Indicator
|
8mm
|
20mm
|
-
|
IP66/IP67 - Dust Tight, Water Resistant, Waterproof
|
CE, cURus
|
|
|
|
PXS
|
Active
|
Box
|
Magnetic
|
DPST-NO/NC
|
100mA (DC)
|
24VDC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
8mm
|
20mm
|
-
|
IP66/IP67 - Dust Tight, Water Resistant, Waterproof
|
CE, cURus
|
|
|
|
PXS
|
Active
|
Box
|
Magnetic
|
3PST-2NC/1NO
|
100mA (DC)
|
24VDC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
8mm
|
20mm
|
-
|
IP66/IP67 - Dust Tight, Water Resistant, Waterproof
|
CE
|
|
|
|
PSS
|
Active
|
Box
|
Magnetic
|
DPST-NC
|
10mA (DC)
|
24VDC
|
24VDC
|
-
|
Non-Contact
|
Cable Leads
|
Status Indicator
|
8mm
|
20mm
|
-
|
IP66/IP67 - Dust Tight, Water Resistant, Waterproof
|
CE, cURus
|
|
|
|
PSS
|
Active
|
Box
|
Magnetic
|
DPST-NC
|
10mA (DC)
|
24VDC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
8mm
|
20mm
|
-
|
IP66/IP67 - Dust Tight, Water Resistant, Waterproof
|
CE, cURus
|
|
|
|
PSS
|
Active
|
Box
|
Magnetic
|
DPST-NC
|
10mA (DC)
|
24VDC
|
-
|
-
|
Non-Contact
|
Wire Leads
|
-
|
8mm
|
20mm
|
-
|
IP66/IP67 - Dust Tight, Water Resistant, Waterproof
|
CE, cURus
|
|
|
|
PSS
|
Active
|
Box
|
Magnetic
|
DPST-NO/NC
|
100mA (DC)
|
24VDC
|
24VDC
|
-
|
Non-Contact
|
Cable Leads
|
Status Indicator
|
5mm
|
15mm
|
-
|
IP66/IP67 - Dust Tight, Water Resistant, Waterproof
|
CE, cURus
|
|
|
|
PSS
|
Active
|
Box
|
Magnetic
|
DPST-NO/NC
|
100mA (DC)
|
24VDC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
5mm
|
15mm
|
-
|
IP66/IP67 - Dust Tight, Water Resistant, Waterproof
|
CE, cURus
|
|
|
|
PSS
|
Active
|
Box
|
Magnetic
|
DPST-NO/NC
|
100mA (DC)
|
24VDC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
5mm
|
15mm
|
-
|
IP66/IP67 - Dust Tight, Water Resistant, Waterproof
|
CE, cURus
|
|
|
|
PSS
|
Active
|
Box
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
|
|
|
PSA
|
Active
|
Box
|
Magnetic
|
SPST-NO
|
3A (AC)
|
440VAC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
15mm
|
-
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, UR
|
|
|
|
PSA
|
Active
|
Box
|
Magnetic
|
SPST-NO
|
3A (AC)
|
440VAC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
15mm
|
-
|
-
|
IP67 - Dust Tight, Waterproof
|
CE
|
|
|
|
PSA
|
Active
|
Box
|
Magnetic
|
SPST-NO
|
3A (AC)
|
440VAC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
15mm
|
-
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cURus
|
|
|
|
PS21S
|
Active
|
Bulk
|
Non-Locking
|
DPST-NO/NC
|
5.5A (AC), 2.8A (DC)
|
130VAC, 24VDC
|
-
|
2kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
1/2" NPT
|
IP65 - Dust Tight, Water Resistant
|
CE, CSA, UL
|
|
|
|
PS21S
|
Active
|
Bulk
|
Non-Locking
|
DPST-NO/NC
|
5.5A (AC), 2.8A (DC)
|
130VAC, 24VDC
|
-
|
2kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
1/2" NPT
|
IP65 - Dust Tight, Water Resistant
|
CE, CSA, UL
|
|
|
|
PS21S
|
Active
|
Bulk
|
Non-Locking
|
DPST-NC
|
5.5A (AC), 2.8A (DC)
|
130VAC, 24VDC
|
-
|
2kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
1/2" NPT
|
IP65 - Dust Tight, Water Resistant
|
CE, CSA, UL
|
|
|
|
PS21S
|
Active
|
Bulk
|
Non-Locking
|
DPST-NC
|
5.5A (AC), 2.8A (DC)
|
130VAC, 24VDC
|
-
|
2kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
1/2" NPT
|
IP65 - Dust Tight, Water Resistant
|
CE, CSA, UL
|
|
|
|
PS21H
|
Active
|
Bulk
|
Hinge
|
DPST-NO/NC
|
5.5A (AC), 2.8A (DC)
|
130VAC, 24VDC
|
-
|
-
|
Shaft
|
Screw Terminal
|
-
|
-
|
-
|
1/2" NPT
|
IP65 - Dust Tight, Water Resistant
|
CE, CSA, UL
|
|
|
|
PS21H
|
Active
|
Bulk
|
Hinge
|
DPST-NO/NC
|
5.5A (AC), 2.8A (DC)
|
130VAC, 24VDC
|
-
|
-
|
Arm Lever
|
Screw Terminal
|
-
|
-
|
-
|
1/2" NPT
|
IP65 - Dust Tight, Water Resistant
|
CE, CSA, UL
|
|
|
|
PBA
|
Active
|
Box
|
Magnetic
|
SPST-NO
|
400mA (DC)
|
250VDC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
-
|
-
|
-
|
-
|
-
|
|
|
|
*
|
Active
|
Bag
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
|
|
|
MFS-STI
|
Active
|
Bulk
|
Magnetic
|
3PST-2NC/1NO
|
2A (AC/DC)
|
230VAC, 30VDC
|
24VDC
|
-
|
Non-Contact
|
Connector (M12)
|
Status Indicator
|
6 ~ 9mm
|
10 ~ 12mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MFS-STI
|
Active
|
Bulk
|
Magnetic
|
3PST-2NC/1NO
|
2A (AC/DC)
|
230VAC, 30VDC
|
24VDC
|
-
|
Non-Contact
|
Cable Leads
|
Status Indicator
|
6 ~ 9mm
|
10 ~ 12mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MFS-STI
|
Active
|
Bulk
|
Magnetic
|
DPST-NC
|
2A (AC/DC)
|
230VAC, 30VDC
|
24VDC
|
-
|
Non-Contact
|
Connector (Micro 1/2"-20)
|
Status Indicator
|
6 ~ 9mm
|
10 ~ 12mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MFS-STI
|
Active
|
Bulk
|
Magnetic
|
DPST-NC
|
2A (AC/DC)
|
230VAC, 30VDC
|
24VDC
|
-
|
Non-Contact
|
Connector (Micro 1/2"-20)
|
Status Indicator
|
6 ~ 9mm
|
10 ~ 12mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MFS-STI
|
Active
|
Bulk
|
Magnetic
|
DPST-NC
|
2A (AC/DC)
|
230VAC, 30VDC
|
24VDC
|
-
|
Non-Contact
|
Cable Leads
|
Status Indicator
|
6 ~ 9mm
|
10 ~ 12mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MFS-STI
|
Active
|
Bulk
|
Magnetic
|
DPST-NC
|
2A (AC/DC)
|
230VAC, 30VDC
|
24VDC
|
-
|
Non-Contact
|
Cable Leads
|
Status Indicator
|
6 ~ 9mm
|
10 ~ 12mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MFS-STI
|
Active
|
Bulk
|
Magnetic
|
DPST-NO/NC
|
2A (AC/DC)
|
230VAC, 30VDC
|
24VDC
|
-
|
Non-Contact
|
Connector (Micro 1/2"-20)
|
Status Indicator
|
6 ~ 9mm
|
10 ~ 12mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MFS-STI
|
Active
|
Bulk
|
Magnetic
|
DPST-NO/NC
|
2A (AC/DC)
|
230VAC, 30VDC
|
24VDC
|
-
|
Non-Contact
|
Connector (Micro 1/2"-20)
|
Status Indicator
|
6 ~ 9mm
|
10 ~ 12mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MFS-STI
|
Active
|
Bulk
|
Magnetic
|
DPST-NO/NC
|
2A (AC/DC)
|
230VAC, 30VDC
|
24VDC
|
-
|
Non-Contact
|
Cable Leads
|
Status Indicator
|
6 ~ 9mm
|
10 ~ 12mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MFS-STI
|
Active
|
Bulk
|
Magnetic
|
DPST-NO/NC
|
2A (AC/DC)
|
230VAC, 30VDC
|
24VDC
|
-
|
Non-Contact
|
Cable Leads
|
Status Indicator
|
6 ~ 9mm
|
10 ~ 12mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MFS-STI
|
Active
|
Bulk
|
Magnetic
|
DPST-NO/NC
|
2A (AC/DC)
|
230VAC, 30VDC
|
24VDC
|
-
|
Non-Contact
|
Cable Leads
|
Status Indicator
|
6 ~ 9mm
|
10 ~ 12mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MF-STI
|
Obsolete
|
Bulk
|
Magnetic
|
DPST-NO/NC
|
500mA (AC/DC)
|
120VAC, 24VDC
|
24VDC
|
-
|
Non-Contact
|
Cable Leads
|
Status Indicator
|
9mm
|
10mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE
|
|
|
|
MF-STI
|
Obsolete
|
Bulk
|
Magnetic
|
DPST-NO/NC
|
500mA (AC/DC)
|
120VAC, 24VDC
|
24VDC
|
-
|
Non-Contact
|
Cable Leads
|
Status Indicator
|
9mm
|
10mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE
|
|
|
|
MC-S-STI
|
Active
|
Bulk
|
Magnetic
|
4PST-3NO/1NC
|
100mA (AC/DC)
|
230VAC, 24VDC
|
-
|
-
|
Non-Contact
|
Cable with Connector (M12)
|
-
|
10mm
|
13mm
|
-
|
IP68 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MC-S-STI
|
Active
|
Bulk
|
Magnetic
|
3PST-2NO/1NC
|
100mA (AC/DC)
|
230VAC, 24VDC
|
-
|
-
|
Non-Contact
|
Cable with Connector (M12)
|
-
|
10mm
|
13mm
|
-
|
IP68 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MC-S-STI
|
Active
|
Bulk
|
Magnetic
|
3PST-2NO/1NC
|
100mA (AC/DC)
|
230VAC, 24VDC
|
-
|
-
|
Non-Contact
|
Cable with Connector (M12)
|
-
|
10mm
|
13mm
|
-
|
IP68 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MC-S-STI
|
Active
|
Bulk
|
Magnetic
|
3PST-2NC/1NO
|
100mA (AC/DC)
|
230VAC, 24VDC
|
-
|
-
|
Non-Contact
|
Cable with Connector (M12)
|
-
|
10mm
|
13mm
|
-
|
IP68 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MC-S-STI
|
Active
|
Bulk
|
Magnetic
|
4PST-3NC/1NO
|
100mA (AC/DC)
|
230VAC, 24VDC
|
-
|
-
|
Non-Contact
|
Cable with Connector (M12)
|
-
|
10mm
|
13mm
|
-
|
IP68 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MC-S-STI
|
Active
|
Bulk
|
Magnetic
|
DPST-NO/NC
|
100mA (AC/DC)
|
230VAC, 24VDC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
5mm
|
11mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MC-S-STI
|
Active
|
Bulk
|
Magnetic
|
3PST-2NO/1NC
|
100mA (AC/DC)
|
230VAC, 24VDC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
9mm
|
12mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MC-S-STI
|
Active
|
Bulk
|
Magnetic
|
3PST-2NO/1NC
|
100mA (AC/DC)
|
230VAC, 24VDC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
9mm
|
12mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MC-S-STI
|
Active
|
Bulk
|
Magnetic
|
3PST-2NC/1NO
|
100mA (AC/DC)
|
230VAC, 24VDC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
9mm
|
12mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MC-S-STI
|
Active
|
Bulk
|
Magnetic
|
3PST-2NC/1NO
|
100mA (AC/DC)
|
230VAC, 24VDC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
9mm
|
12mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MC-S-STI
|
Active
|
Bulk
|
Magnetic
|
DPST-NO/NC
|
100mA (AC/DC)
|
230VAC, 24VDC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
9mm
|
12mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MC-S-STI
|
Active
|
Bulk
|
Magnetic
|
DPST-NO/NC
|
100mA (AC/DC)
|
230VAC, 24VDC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
9mm
|
12mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MC-S-STI
|
Active
|
Bulk
|
Magnetic
|
4PST-3NO/1NC
|
100mA (AC/DC)
|
230VAC, 24VDC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
5mm
|
11mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MC-S-STI
|
Active
|
Bulk
|
Magnetic
|
4PST-3NO/1NC
|
100mA (AC/DC)
|
230VAC, 24VDC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
5mm
|
11mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MC-S-STI
|
Active
|
Bulk
|
Magnetic
|
4PST-3NC/1NO
|
100mA (AC/DC)
|
230VAC, 24VDC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
5mm
|
11mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MC-S-STI
|
Active
|
Bulk
|
Magnetic
|
4PST-3NC/1NO
|
100mA (AC/DC)
|
230VAC, 24VDC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
5mm
|
11mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MC-S-STI
|
Active
|
Bulk
|
Magnetic
|
DPST-NO/NC
|
100mA (AC/DC)
|
230VAC, 24VDC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
5mm
|
11mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MC-S-STI
|
Active
|
Bulk
|
Magnetic
|
DPST-NO/NC
|
100mA (AC/DC)
|
230VAC, 24VDC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
5mm
|
11mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MC-S-STI
|
Active
|
Bulk
|
Magnetic
|
-
|
100mA (AC/DC)
|
230VAC, 24VDC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
5mm
|
11mm
|
-
|
IP68 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
3PST-2NC/1NO
|
1A (DC)
|
30VDC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
DPST-NC
|
1A (DC)
|
30VDC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
3PST-2NC/1NO
|
1A (DC)
|
30VDC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
3PST-2NC/1NO
|
1A (DC)
|
30VDC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
DPST-NC
|
1A (DC)
|
30VDC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
DPST-NC
|
1A (DC)
|
30VDC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
DPST-NO/NC
|
1A (DC)
|
30VDC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
DPST-NO/NC
|
1A (DC)
|
30VDC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
SPST-NC
|
1A (DC)
|
30VDC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
SPST-NC
|
1A (DC)
|
30VDC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
3PST-2NC/1NO
|
2A (AC)
|
230VAC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
3PST-2NC/1NO
|
2A (AC)
|
230VAC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
DPST-NC
|
2A (AC)
|
230VAC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
DPST-NC
|
2A (AC)
|
230VAC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
DPST-NO/NC
|
2A (AC)
|
230VAC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
DPST-NO/NC
|
2A (AC)
|
230VAC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
SPST-NC
|
2A (AC)
|
230VAC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
DPST-NO/NC
|
1A (DC)
|
30VDC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
DPST-NO/NC
|
1A (DC)
|
30VDC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
DPST-NO/NC
|
2A (AC)
|
230VAC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
DPST-NO/NC
|
2A (AC)
|
230VAC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
3PST-2NC/1NO
|
1A (DC)
|
30VDC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
3PST-2NC/1NO
|
1A (DC)
|
30VDC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
3PST-2NC/1NO
|
2A (AC)
|
230VAC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
3PST-2NC/1NO
|
2A (AC)
|
230VAC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
DPST-NC
|
1A (DC)
|
30VDC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
DPST-NC
|
1A (DC)
|
30VDC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
DPST-NC
|
2A (AC)
|
230VAC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
DPST-NC
|
2A (AC)
|
230VAC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
SPST-NC
|
1A (DC)
|
30VDC
|
-
|
-
|
Non-Contact
|
Connector (Micro AC)
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
SPST-NC
|
1A (DC)
|
30VDC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
SPST-NC
|
1A (DC)
|
30VDC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Obsolete
|
Bulk
|
Magnetic
|
SPST-NC
|
2A (AC)
|
230VAC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
SPST-NC
|
2A (AC)
|
230VAC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
SPST-NC
|
2A (AC)
|
230VAC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
SPST-NC
|
2A (AC)
|
230VAC
|
-
|
-
|
Non-Contact
|
Screw Terminal
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP65 - Dust Tight, Water Resistant
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
DPST-NO/NC
|
2A (AC)
|
230VAC
|
-
|
-
|
Non-Contact
|
Screw Terminal
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP65 - Dust Tight, Water Resistant
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
DPST-NO/NC
|
3A (AC)
|
230VAC
|
-
|
-
|
Non-Contact
|
Screw Terminal
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP65 - Dust Tight, Water Resistant
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
DPST-NO/NC
|
1A (DC)
|
30VDC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
SPST-NC
|
1A (DC)
|
30VDC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
SPST-NC
|
2A (AC)
|
230VAC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
SPST-NC
|
2A (AC)
|
230VAC
|
-
|
-
|
Non-Contact
|
Connector (Micro AC)
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
SPST-NC
|
2A (AC)
|
230VAC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
3PST-2NC/1NO
|
1A (DC)
|
30VDC
|
-
|
-
|
Non-Contact
|
Connector (Micro AC)
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
3PST-2NC/1NO
|
1A (DC)
|
30VDC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
3PST-2NC/1NO
|
1A (DC)
|
30VDC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
3PST-2NC/1NO
|
1A (DC)
|
30VDC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
3PST-2NC/1NO
|
1A (DC)
|
30VDC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
DPST-NO/NC
|
2A (AC)
|
30VDC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
SPST-NC
|
2A (AC)
|
30VDC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
SPST-NC
|
2A (AC)
|
30VDC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
DPST-NO/NC
|
1A (DC)
|
30VDC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
DPST-NO/NC
|
1A (DC)
|
30VDC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
DPST-NO/NC
|
1A (DC)
|
30VDC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
DPST-NO/NC
|
1A (DC)
|
30VDC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
DPST-NO/NC
|
1A (DC)
|
30VDC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
DPST-NO/NC
|
2A (AC)
|
230VAC
|
-
|
-
|
Non-Contact
|
Connector (Micro AC)
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
DPST-NO/NC
|
2A (AC)
|
230VAC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
DPST-NO/NC
|
2A (AC)
|
230VAC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
DPST-NO/NC
|
2A (AC)
|
230VAC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
DPST-NO/NC
|
2A (AC)
|
230VAC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
DPST-NO/NC
|
2A (AC)
|
230VAC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
3PST-2NC/1NO
|
1A (DC)
|
30VDC
|
-
|
-
|
Non-Contact
|
Connector (Micro AC)
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
3PST-2NC/1NO
|
1A (DC)
|
30VDC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
3PST-2NC/1NO
|
1A (DC)
|
30VDC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
3PST-2NC/1NO
|
1A (DC)
|
30VDC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
3PST-2NC/1NO
|
1A (DC)
|
30VDC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
3PST-2NC/1NO
|
1A (DC)
|
30VDC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
3PST-2NC/1NO
|
2A (AC)
|
230VAC
|
-
|
-
|
Non-Contact
|
Connector (Micro AC)
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
3PST-2NC/1NO
|
2A (AC)
|
230VAC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
3PST-2NC/1NO
|
2A (AC)
|
230VAC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
3PST-2NC/1NO
|
2A (AC)
|
230VAC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
3PST-2NC/1NO
|
2A (AC)
|
230VAC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
3PST-2NC/1NO
|
2A (AC)
|
230VAC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
DPST-NC
|
1A (DC)
|
30VDC
|
-
|
-
|
Non-Contact
|
Connector (Micro AC)
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
DPST-NC
|
1A (DC)
|
30VDC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
DPST-NC
|
2A (AC)
|
230VAC
|
-
|
-
|
Non-Contact
|
Connector (Micro AC)
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
DPST-NC
|
2A (AC)
|
230VAC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
SPST-NC
|
1A (DC)
|
30VDC
|
-
|
-
|
Non-Contact
|
Connector (M12)
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
SPST-NC
|
1A (DC)
|
30VDC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
SPST-NC
|
1A (DC)
|
30VDC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
SPST-NC
|
1A (DC)
|
30VDC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
SPST-NC
|
2A (AC)
|
230VAC
|
-
|
-
|
Non-Contact
|
Connector (M12)
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
SPST-NC
|
2A (AC)
|
230VAC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
SPST-NC
|
2A (AC)
|
230VAC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
SPST-NC
|
2A (AC)
|
230VAC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
SPST-NC
|
2A (AC)
|
230VAC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
SPST-NC
|
1A (DC)
|
30VDC
|
-
|
-
|
Non-Contact
|
Connector (M12)
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
SPST-NC
|
1A (DC)
|
30VDC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
SPST-NC
|
2A (AC)
|
230VAC
|
-
|
-
|
Non-Contact
|
Connector (M12)
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
SPST-NC
|
2A (AC)
|
230VAC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
SPST-NC
|
2A (AC)
|
230VAC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
3PST-2NC/1NO
|
300mA (DC)
|
30VDC
|
-
|
-
|
Non-Contact
|
Connector (M12)
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
3PST-2NC/1NO
|
300mA (DC)
|
30VDC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
3PST-2NC/1NO
|
300mA (DC)
|
30VDC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
3PST-2NC/1NO
|
300mA (DC)
|
30VDC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
3PST-2NC/1NO
|
300mA (DC)
|
30VDC
|
-
|
-
|
Non-Contact
|
Connector (M12)
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
DPST-NO/NC
|
1A (DC)
|
30VDC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
SPST-NC
|
1A (DC)
|
30VDC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
3PST-2NC/1NO
|
1A (DC)
|
30VDC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
3PST-2NC/1NO
|
1A (DC)
|
30VDC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
DPST-NC
|
1A (DC)
|
30VDC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
DPST-NO/NC
|
1A (DC)
|
30VDC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
SPST-NC
|
1A (DC)
|
30VDC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
3PST-2NC/1NO
|
2A (AC)
|
230VAC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
DPST-NC
|
2A (AC)
|
230VAC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
DPST-NO/NC
|
2A (AC)
|
230VAC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
SPST-NC
|
2A (AC)
|
230VAC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
DPST-NO/NC
|
1A (DC)
|
30VDC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
SPST-NC
|
1A (DC)
|
30VDC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
DPST-NO/NC
|
2A (AC)
|
230VAC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
SPST-NC
|
2A (AC)
|
230VAC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
3PST-2NC/1NO
|
1A (DC)
|
30VDC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
DPST-NC
|
1A (DC)
|
30VDC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
DPST-NC
|
1A (DC)
|
30VDC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
DPST-NO/NC
|
1A (DC)
|
30VDC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
SPST-NC
|
1A (DC)
|
30VDC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
3PST-2NC/1NO
|
2A (AC)
|
230VAC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
DPST-NC
|
2A (AC)
|
230VAC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
DPST-NO/NC
|
2A (AC)
|
230VAC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
DPST-NO/NC
|
2A (AC)
|
230VAC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
SPST-NC
|
2A (AC)
|
230VAC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
SPST-NC
|
2A (AC)
|
110VAC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
MA-STI
|
Active
|
Bulk
|
Magnetic
|
SPST-NC
|
2A (AC)
|
110VAC
|
-
|
-
|
Non-Contact
|
Cable Leads
|
-
|
7 ~ 12mm
|
12 ~ 25mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
KEX
|
Active
|
Bulk
|
Trapped Key Exchange Unit
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
KEX
|
Active
|
Bulk
|
Trapped Key Exchange Unit
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
KEX
|
Active
|
Bulk
|
Trapped Key Exchange Unit
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
KEX
|
Active
|
Bulk
|
Trapped Key Exchange Unit
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
KEX
|
Active
|
Bulk
|
Trapped Key Exchange Unit
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
KEX
|
Active
|
Bulk
|
Trapped Key Exchange Unit
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
KEX
|
Active
|
Bulk
|
Trapped Key Exchange Unit
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
KEX
|
Active
|
Bulk
|
Trapped Key Exchange Unit
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
KEX
|
Active
|
Bulk
|
Trapped Key Exchange Unit
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
KEX
|
Active
|
Bulk
|
Trapped Key Exchange Unit
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
KEX
|
Active
|
Bulk
|
Trapped Key Exchange Unit
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
KEX
|
Active
|
Bulk
|
Trapped Key Exchange Unit
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
KEX
|
Active
|
Bulk
|
Trapped Key Exchange Unit
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
KEX
|
Active
|
Bulk
|
Trapped Key Exchange Unit
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
KEX
|
Active
|
Bulk
|
Trapped Key Exchange Unit
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
KEX
|
Active
|
Bulk
|
Trapped Key Exchange Unit
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
KEX
|
Active
|
Bulk
|
Trapped Key Exchange Unit
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
KEX
|
Active
|
Bulk
|
Trapped Key Exchange Unit
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
KEX
|
Active
|
Bulk
|
Trapped Key Exchange Unit
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
KEX
|
Active
|
Bulk
|
Trapped Key Exchange Unit
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
KEX
|
Obsolete
|
Bulk
|
Trapped Key Exchange Unit
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
KEX
|
Active
|
Bulk
|
Trapped Key Exchange Unit
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
KEX
|
Active
|
Bulk
|
Trapped Key Exchange Unit
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
KEX
|
Active
|
Bulk
|
Trapped Key Exchange Unit
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
KEX
|
Active
|
Bulk
|
Trapped Key Exchange Unit
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
KEX
|
Active
|
Bulk
|
Trapped Key Exchange Unit
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
KEX
|
Active
|
Bulk
|
Trapped Key Exchange Unit
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
KEX
|
Active
|
Bulk
|
Trapped Key Exchange Unit
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
KEX
|
Active
|
Bulk
|
Trapped Key Exchange Unit
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
KEX
|
Active
|
Bulk
|
Trapped Key Exchange Unit
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
KEX
|
Active
|
Bulk
|
Trapped Key Exchange Unit
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
KEX
|
Active
|
Bulk
|
Trapped Key Exchange Unit
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
KEX
|
Active
|
Bulk
|
Trapped Key Exchange Unit
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
KEX
|
Active
|
Bulk
|
Trapped Key Exchange Unit
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
KEX
|
Active
|
Bulk
|
Trapped Key Exchange Unit
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
KEX
|
Active
|
Bulk
|
Trapped Key Exchange Unit
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
KEX
|
Active
|
Bulk
|
Trapped Key Exchange Unit
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
KEX
|
Active
|
Bulk
|
Trapped Key Exchange Unit
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
KEX
|
Active
|
Bulk
|
Trapped Key Exchange Unit
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
KEX
|
Active
|
Bulk
|
Trapped Key Exchange Unit
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
KEX
|
Active
|
Bulk
|
Trapped Key Exchange Unit
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
KEX
|
Active
|
Bulk
|
Trapped Key Exchange Unit
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
KEX
|
Active
|
Bulk
|
Trapped Key Exchange Unit
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
KEX
|
Active
|
Bulk
|
Trapped Key Exchange Unit
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
KEX
|
Obsolete
|
Bulk
|
Trapped Key Exchange Unit
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
KEX
|
Obsolete
|
Bulk
|
Trapped Key Exchange Unit
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
KEX
|
Active
|
Bulk
|
Trapped Key Exchange Unit
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
KEX
|
Active
|
Bulk
|
Trapped Key Exchange Unit
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
KEX
|
Active
|
Bulk
|
Trapped Key Exchange Unit
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
KEX
|
Active
|
Bulk
|
Trapped Key Exchange Unit
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
KEX
|
Active
|
Bulk
|
Trapped Key Exchange Unit
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
KEX
|
Active
|
Bulk
|
Trapped Key Exchange Unit
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
KEX
|
Active
|
Bulk
|
Trapped Key Exchange Unit
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
KEX
|
Active
|
Bulk
|
Trapped Key Exchange Unit
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
KEX
|
Active
|
Bulk
|
Trapped Key Exchange Unit
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
KEX
|
Active
|
Bulk
|
Trapped Key Exchange Unit
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
KEX
|
Active
|
Bulk
|
Trapped Key Exchange Unit
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
KEX
|
Active
|
Bulk
|
Trapped Key Exchange Unit
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
KEX
|
Active
|
Bulk
|
Trapped Key Exchange Unit
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
KEX
|
Active
|
Bulk
|
Trapped Key Exchange Unit
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
KEX
|
Active
|
Bulk
|
Trapped Key Exchange Unit
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
KEX
|
Active
|
Bulk
|
Trapped Key Exchange Unit
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
KEX
|
Active
|
Bulk
|
Trapped Key Exchange Unit
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
KEX
|
Active
|
Bulk
|
Trapped Key Exchange Unit
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
KEX
|
Active
|
Bulk
|
Trapped Key Exchange Unit
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
KEX
|
Active
|
Bulk
|
Trapped Key Exchange Unit
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
KEX
|
Active
|
Bulk
|
Trapped Key Exchange Unit
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
KEX
|
Active
|
Bulk
|
Trapped Key Exchange Unit
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
KEX
|
Active
|
Bulk
|
Trapped Key Exchange Unit
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
KEX
|
Active
|
Bulk
|
Trapped Key Exchange Unit
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
KEX
|
Active
|
Bulk
|
Trapped Key Exchange Unit
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
KEX
|
Active
|
Bulk
|
Trapped Key Exchange Unit
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
KEX
|
Active
|
Bulk
|
Trapped Key Exchange Unit
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
KEX
|
Active
|
Bulk
|
Trapped Key Exchange Unit
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
KEX
|
Active
|
Bulk
|
Trapped Key Exchange Unit
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
KEX
|
Active
|
Bulk
|
Trapped Key Exchange Unit
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
KEX
|
Active
|
Bulk
|
Trapped Key Exchange Unit
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
KEX
|
Active
|
Bulk
|
Trapped Key Exchange Unit
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
KEX
|
Active
|
Bulk
|
Trapped Key Exchange Unit
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
KEX
|
Active
|
Bulk
|
Trapped Key Exchange Unit
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
KEX
|
Active
|
Bulk
|
Trapped Key Exchange Unit
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
KEX
|
Active
|
Bulk
|
Trapped Key Exchange Unit
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
KEX
|
Active
|
Bulk
|
Trapped Key Exchange Unit
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
KEX
|
Active
|
Bulk
|
Trapped Key Exchange Unit
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
KEX
|
Active
|
Bulk
|
Trapped Key Exchange Unit
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
KEX
|
Active
|
Bulk
|
Trapped Key Exchange Unit
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
KEX
|
Active
|
Bulk
|
Trapped Key Exchange Unit
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
KEX
|
Active
|
Bulk
|
Trapped Key Exchange Unit
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
KEX
|
Active
|
Bulk
|
Trapped Key Exchange Unit
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
KEX
|
Active
|
Bulk
|
Trapped Key Exchange Unit
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
KEX
|
Active
|
Bulk
|
Trapped Key Exchange Unit
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
KEX
|
Active
|
Bulk
|
Trapped Key Exchange Unit
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
KEX
|
Active
|
Bulk
|
Trapped Key Exchange Unit
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
KEX
|
Active
|
Bulk
|
Trapped Key Exchange Unit
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
KEX
|
Active
|
Bulk
|
Trapped Key Exchange Unit
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
KEX
|
Active
|
Bulk
|
Trapped Key Exchange Unit
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
KEX
|
Active
|
Bulk
|
Trapped Key Exchange Unit
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
KEX
|
Active
|
Bulk
|
Trapped Key Exchange Unit
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
KEX
|
Active
|
Bulk
|
Trapped Key Exchange Unit
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
KEX
|
Active
|
Bulk
|
Trapped Key Exchange Unit
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
KEX
|
Active
|
Bulk
|
Trapped Key Exchange Unit
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
KEX
|
Active
|
Bulk
|
Trapped Key Exchange Unit
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
CE
|
|
|
|
IN4000
|
Active
|
Bulk
|
Inductive
|
-
|
-
|
-
|
24VDC
|
-
|
Non-Contact
|
Connector (M12)
|
Staus Indicator
|
10 ~ 15mm
|
30mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
IN4000
|
Active
|
Bulk
|
Inductive
|
-
|
-
|
-
|
24VDC
|
-
|
Non-Contact
|
Connector (M12)
|
-
|
3 ~ 6mm
|
15mm
|
-
|
IP69K - Dust Tight, High Temp Water Jets, Waterproof
|
CE, cULus
|
|
|
|
IN4000
|
Active
|
Bulk
|
Inductive
|
-
|
-
|
-
|
24VDC
|
-
|
Non-Contact
|
Connector (M12)
|
Staus Indicator
|
10 ~ 15mm
|
30mm
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
i200 Lock
|
Active
|
Bulk
|
Solenoid Release
|
5PST-4NC/1NO
|
3A (AC/DC)
|
240VAC, 24VDC
|
20.4 ~ 26.4VDC
|
265kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP65 - Dust Tight, Water Resistant
|
CCC, CE, cULus
|
|
|
|
i200 Lock
|
Active
|
Bulk
|
Solenoid Release
|
5PST-3NC/2NO
|
3A (AC/DC)
|
240VAC, 24VDC
|
20.4 ~ 26.4VDC
|
265kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP65 - Dust Tight, Water Resistant
|
CCC, CE, cULus
|
|
|
|
i200 Lock
|
Active
|
Bulk
|
Solenoid Locking
|
5PST-3NC/2NO
|
3A (AC/DC)
|
240VAC, 24VDC
|
20.4 ~ 26.4VDC
|
265kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP65 - Dust Tight, Water Resistant
|
CCC, CE, cULus
|
|
|
|
i17S
|
Active
|
Bulk
|
Non-Locking
|
3PST-2NC/1NO
|
3A (AC), 2A (DC)
|
240VAC, 24VDC
|
-
|
1kgf
|
Panel Disconnect
|
Connector (M12)
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CCC, CE, cULus
|
|
|
|
i17S
|
Active
|
Bulk
|
Non-Locking
|
3PST-2NC/1NO
|
3A (AC), 2A (DC)
|
240VAC, 24VDC
|
-
|
1kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CCC, CE, cULus
|
|
|
|
i16S
|
Active
|
Bulk
|
Non-Locking
|
DPST-NC
|
2A (DC)
|
24VDC
|
-
|
3kgf
|
Panel Disconnect
|
Connector (M12)
|
-
|
-
|
-
|
-
|
IP67 - Dust Tight, Waterproof
|
CCC, CE, cULus
|
|
|
|
i16S
|
Active
|
Bulk
|
Non-Locking
|
DPST-NC
|
3A (AC), 2A (DC)
|
240VAC, 24VDC
|
-
|
3kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CCC, CE, cULus
|
|
|
|
i16S
|
Active
|
Bulk
|
Non-Locking
|
DPST-NO/NC
|
3A (AC), 2A (DC)
|
240VAC, 24VDC
|
-
|
3kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CCC, CE, cULus
|
|
|
|
i15 Lock
|
Active
|
Bulk
|
Solenoid Release
|
3PST-2NC/1NO
|
4A (AC/DC)
|
230VAC, 24VDC
|
20.4 ~ 26.4VDC
|
102kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
i15 Lock
|
Active
|
Bulk
|
Solenoid Release
|
3PST-NC
|
4A (AC/DC)
|
230VAC, 24VDC
|
20.4 ~ 26.4VDC
|
102kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
i15 Lock
|
Active
|
Bulk
|
Solenoid Release
|
3PST-2NC/1NO
|
4A (AC/DC)
|
230VAC, 24VDC
|
20.4 ~ 26.4VDC
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
i15 Lock
|
Active
|
Bulk
|
Solenoid Release
|
3PST-NC
|
4A (AC/DC)
|
230VAC, 24VDC
|
20.4 ~ 26.4VDC
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
i15 Lock
|
Active
|
Bulk
|
Solenoid Locking
|
3PST-2NC/1NO
|
4A (AC/DC)
|
230VAC, 24VDC
|
20.4 ~ 26.4VDC
|
102kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
i15 Lock
|
Active
|
Bulk
|
Solenoid Locking
|
3PST-NC
|
4A (AC/DC)
|
230VAC, 24VDC
|
20.4 ~ 26.4VDC
|
102kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
i15 Lock
|
Active
|
Bulk
|
Solenoid Locking
|
3PST-2NC/1NO
|
4A (AC/DC)
|
230VAC, 24VDC
|
20.4 ~ 26.4VDC
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
i15 Lock
|
Active
|
Bulk
|
Solenoid Locking
|
3PST-NC
|
4A (AC/DC)
|
230VAC, 24VDC
|
20.4 ~ 26.4VDC
|
204kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
i14 Lock
|
Active
|
Bulk
|
Solenoid Release
|
3PST-NC
|
3A (AC), 2A (DC)
|
240VAC, 24VDC
|
20.4 ~ 26.4VDC
|
102kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20
|
IP65 - Dust Tight, Water Resistant
|
CCC, CE, cULus
|
|
|
|
i14 Lock
|
Active
|
Bulk
|
Solenoid Release
|
3PST-2NC/1NO
|
3A (AC), 2A (DC)
|
240VAC, 24VDC
|
20.4 ~ 26.4VDC
|
102kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20
|
IP65 - Dust Tight, Water Resistant
|
CCC, CE, cULus
|
|
|
|
i12S
|
Active
|
Bulk
|
Non-Locking
|
3PST-2NC/1NO
|
3A (AC), 2A (DC)
|
240VAC, 24VDC
|
-
|
2kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M16
|
IP67 - Dust Tight, Waterproof
|
CCC, CE, cULus
|
|
|
|
i12S
|
Active
|
Bulk
|
Non-Locking
|
DPST-NC
|
2A (DC)
|
24VDC
|
-
|
612gf
|
Panel Disconnect
|
Connector (M12)
|
-
|
-
|
-
|
-
|
IP67 - Dust Tight, Waterproof
|
CCC, CE, cULus
|
|
|
|
i12S
|
Active
|
Bulk
|
Non-Locking
|
DPST-NC
|
3A (AC), 2A (DC)
|
240VAC, 24VDC
|
-
|
612gf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M16
|
IP67 - Dust Tight, Waterproof
|
CCC, CE, cULus
|
|
|
|
i12S
|
Active
|
Bulk
|
Non-Locking
|
DPST-NO/NC
|
3A (AC), 2A (DC)
|
240VAC, 24VDC
|
-
|
612gf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M16
|
IP67 - Dust Tight, Waterproof
|
CCC, CE, cULus
|
|
|
|
i110S
|
Active
|
Bulk
|
Non-Locking
|
4PST-3NC/1NO
|
3A (AC), 2A (DC)
|
240VAC, 24VDC
|
-
|
1kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20
|
IP67 - Dust Tight, Waterproof
|
CCC, CE, cULus
|
|
|
|
i110S
|
Active
|
Bulk
|
Non-Locking
|
DPST-NC
|
2A (DC)
|
24VDC
|
-
|
1kgf
|
Panel Disconnect
|
Connector (M12)
|
-
|
-
|
-
|
-
|
IP67 - Dust Tight, Waterproof
|
CCC, CE, cULus
|
|
|
|
i110S
|
Active
|
Bulk
|
Non-Locking
|
4PST-2NO/2NC
|
3A (AC), 2A (DC)
|
240VAC, 24VDC
|
-
|
1kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20
|
IP67 - Dust Tight, Waterproof
|
CCC, CE, cULus
|
|
|
|
i110 Lock
|
Active
|
Bulk
|
Solenoid Locking
|
SPST-NC
|
1A (AC/DC)
|
24VAC/DC
|
24VAC/DC
|
255kgf
|
Panel Disconnect
|
Connector (M12)
|
-
|
-
|
-
|
-
|
IP67 - Dust Tight, Waterproof
|
CCC, CE, cULus
|
|
|
|
i11S
|
Active
|
Bulk
|
Non-Locking
|
3PST-2NC/1NO
|
4A (AC/DC)
|
230VAC, 24VDC
|
-
|
1kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M16 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
i10 Lock
|
Active
|
Bulk
|
Solenoid Release
|
3PST-NC
|
1A (AC/DC)
|
24VAC/DC
|
24VDC
|
133kgf
|
Panel Disconnect
|
Connector (M12)
|
-
|
-
|
-
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
i10 Lock
|
Active
|
Bulk
|
Solenoid Release
|
DPST-NC
|
4A (AC/DC)
|
230VAC, 24VDC
|
24VDC
|
133kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
i10 Lock
|
Active
|
Bulk
|
Solenoid Release
|
4PST-3NC/1NO
|
4A (AC/DC)
|
230VAC, 24VDC
|
24VDC
|
133kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
i10 Lock
|
Active
|
Bulk
|
Solenoid Release
|
3PST-2NC/1NO
|
4A (AC/DC)
|
230VAC, 24VDC
|
24VDC
|
133kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
i10H
|
Active
|
Bulk
|
Hinge
|
3PST-2NC/1NO
|
3A (AC), 2A (DC)
|
240VAC, 24VDC
|
-
|
-
|
Shaft
|
Screw Terminal
|
-
|
-
|
-
|
M16
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
i10H
|
Active
|
Bulk
|
Hinge
|
DPST-NO/NC
|
3A (AC), 2A (DC)
|
240VAC, 24VDC
|
-
|
-
|
Shaft
|
Screw Terminal
|
-
|
-
|
-
|
M16
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
i10 Lock
|
Active
|
Bulk
|
Solenoid Locking
|
3PST-NC
|
1A (AC/DC)
|
24VAC/DC
|
24VDC
|
133kgf
|
Panel Disconnect
|
Connector (M12)
|
-
|
-
|
-
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
i10 Lock
|
Active
|
Bulk
|
Solenoid Locking
|
4PST-NC
|
4A (AC/DC)
|
230VAC, 24VDC
|
24VDC
|
133kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
i10 Lock
|
Active
|
Bulk
|
Solenoid Locking
|
3PST-NC
|
1A (AC/DC)
|
24VAC/DC
|
24VDC
|
133kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
i10 Lock
|
Active
|
Bulk
|
Solenoid Locking
|
4PST-3NC/1NO
|
4A (AC/DC)
|
230VAC, 24VDC
|
24VDC
|
133kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
i10 Lock
|
Active
|
Bulk
|
Solenoid Locking
|
4PST-3NC/1NO
|
4A (AC/DC)
|
230VAC, 24VDC
|
24VDC
|
133kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
i10 Lock
|
Active
|
Bulk
|
Solenoid Locking
|
4PST-3NC/1NO
|
4A (AC/DC)
|
230VAC, 24VDC
|
24VDC
|
133kgf
|
Panel Disconnect
|
Screw Terminal
|
-
|
-
|
-
|
M20 x3
|
IP67 - Dust Tight, Waterproof
|
CE, cULus
|
|
|
|
HS6E
|
Active
|
Bulk
|
Solenoid Locking
|
3PST-NC + DPST-NC
|
2.5A (AC/DC)
|
125VAC, 30VDC
|
24VDC
|
51kgf
|
Panel Disconnect
|
Cable Leads
|
Cable Length 3m
|
-
|
-
|
-
|
IP67 - Dust Tight, Waterproof
|
CE, cULus, TUV
|
|
|
|
HS6B
|
Active
|
Bulk
|
Non-Locking
|
3PST-2NC/1NO
|
2.5A (AC/DC)
|
125VAC, 30VDC
|
-
|
6kgf
|
Panel Disconnect
|
Cable Leads
|
Cable Length 1m
|
-
|
-
|
-
|
IP67 - Dust Tight, Waterproof
|
CCC, CE, cULus, TUV
|
|
|
|
HS5L
|
Active
|
Bulk
|
Solenoid Locking
|
3PST-2NC/1NO + SPST-NC
|
2.5A (AC/DC)
|
125VAC, 30VDC
|
24VDC
|
143kgf
|
Panel Disconnect
|
Spring Terminal
|
-
|
-
|
-
|
M20
|
IP67 - Dust Tight, Waterproof
|
CCC, CE, TUV, UL
|
|
|
|
HS5L
|
Active
|
Bulk
|
Solenoid Release
|
3PST-2NC/1NO + SPST-NC
|
2.5A (AC/DC)
|
125VAC, 30VDC
|
24VDC
|
143kgf
|
Panel Disconnect
|
Spring Terminal
|
-
|
-
|
-
|
M20
|
IP67 - Dust Tight, Waterproof
|
CCC, CE, TUV, UL
|
|
|
|
HS5L
|
Active
|
Bulk
|
Solenoid Locking
|
3PST-2NC/1NO + SPST-NC
|
2.5A (AC/DC)
|
125VAC, 30VDC
|
24VDC
|
143kgf
|
Panel Disconnect
|
Spring Terminal
|
-
|
-
|
-
|
M20
|
IP67 - Dust Tight, Waterproof
|
CCC, CE, TUV, UL
|
|
|
|
HS5L
|
Active
|
Bulk
|
Solenoid Release
|
3PST-2NC/1NO + SPST-NC
|
2.5A (AC/DC)
|
125VAC, 30VDC
|
24VDC
|
143kgf
|
Panel Disconnect
|
Spring Terminal
|
-
|
-
|
-
|
M20
|
IP67 - Dust Tight, Waterproof
|
CCC, CE, TUV, UL
|
|
|
|
HS5L
|
Active
|
Bulk
|
Solenoid Locking
|
3PST-NC + SPST-NC
|
2.5A (AC/DC)
|
125VAC, 30VDC
|
24VDC
|
143kgf
|
Panel Disconnect
|
Spring Terminal
|
-
|
-
|
-
|
M20
|
IP67 - Dust Tight, Waterproof
|
CCC, CE, TUV, UL
|
|
|
|
HS5L
|
Active
|
Bulk
|
Solenoid Release
|
3PST-NC + SPST-NC
|
2.5A (AC/DC)
|
125VAC, 30VDC
|
24VDC
|
143kgf
|
Panel Disconnect
|
Spring Terminal
|
-
|
-
|
-
|
M20
|
IP67 - Dust Tight, Waterproof
|
CCC, CE, TUV, UL
|
|
|
|
HS5L
|
Active
|
Bulk
|
Solenoid Locking
|
DPST-NC x 2
|
2.5A (AC/DC)
|
125VAC, 30VDC
|
24VDC
|
143kgf
|
Panel Disconnect
|
Spring Terminal
|
-
|
-
|
-
|
M20
|
IP67 - Dust Tight, Waterproof
|
CCC, CE, TUV, UL
|
|
|
|
HS5L
|
Active
|
Bulk
|
Solenoid Release
|
DPST-NC x 2
|
2.5A (AC/DC)
|
125VAC, 30VDC
|
24VDC
|
143kgf
|
Panel Disconnect
|
Spring Terminal
|
-
|
-
|
-
|
M20
|
IP67 - Dust Tight, Waterproof
|
CCC, CE, TUV, UL
|
|
|
|
HS5L
|
Active
|
Bulk
|
Solenoid Release
|
DPST-NC x 2
|
2.5A (AC/DC)
|
125VAC, 30VDC
|
24VDC
|
143kgf
|
Panel Disconnect
|
Spring Terminal
|
-
|
-
|
-
|
M20
|
IP67 - Dust Tight, Waterproof
|
CCC, CE, TUV, UL
|
|
|
|
HS5L
|
Active
|
Bulk
|
Solenoid Locking
|
DPST-NO/NC + DPST-NC
|
2.5A (AC/DC)
|
125VAC, 30VDC
|
24VDC
|
143kgf
|
Panel Disconnect
|
Spring Terminal
|
-
|
-
|
-
|
M20
|
IP67 - Dust Tight, Waterproof
|
CCC, CE, TUV, UL
|
|
|
|
HS5L
|
Active
|
Bulk
|
Solenoid Release
|
DPST-NO/NC + DPST-NC
|
2.5A (AC/DC)
|
125VAC, 30VDC
|
24VDC
|
143kgf
|
Panel Disconnect
|
Spring Terminal
|
-
|
-
|
-
|
M20
|
IP67 - Dust Tight, Waterproof
|
CCC, CE, TUV, UL
|
|
|
|
HS5L
|
Active
|
Bulk
|
Solenoid Release
|
DPST-NO/NC + DPST-NC
|
2.5A (AC/DC)
|
125VAC, 30VDC
|
24VDC
|
143kgf
|
Panel Disconnect
|
Spring Terminal
|
-
|
-
|
-
|
M20
|
IP67 - Dust Tight, Waterproof
|
CCC, CE, TUV, UL
|
|
|
|
HS5L
|
Active
|
Bulk
|
Solenoid Locking
|
DPST-NO/NC + DPST-NC
|
2.5A (AC/DC)
|
125VAC, 30VDC
|
24VDC
|
143kgf
|
Panel Disconnect
|
Spring Terminal
|
-
|
-
|
-
|
M20
|
IP67 - Dust Tight, Waterproof
|
CCC, CE, TUV, UL
|
|
|
|
HS5L
|
Active
|
Bulk
|
Solenoid Release
|
DPST-NO/NC + DPST-NC
|
2.5A (AC/DC)
|
125VAC, 30VDC
|
24VDC
|
143kgf
|
Panel Disconnect
|
Spring Terminal
|
-
|
-
|
-
|
M20
|
IP67 - Dust Tight, Waterproof
|
CCC, CE, TUV, UL
|
|
|
|
HS5L
|
Active
|
Bulk
|
Solenoid Release
|
DPST-NO/NC + DPST-NC
|
2.5A (AC/DC)
|
125VAC, 30VDC
|
24VDC
|
143kgf
|
Panel Disconnect
|
Spring Terminal
|
-
|
-
|
-
|
M20
|
IP67 - Dust Tight, Waterproof
|
CCC, CE, TUV, UL
|
|
|
|
HS5L
|
Active
|
Bulk
|
Solenoid Locking
|
DPST-NO/NC x 2
|
2.5A (AC/DC)
|
125VAC, 30VDC
|
24VDC
|
143kgf
|
Panel Disconnect
|
Spring Terminal
|
-
|
-
|
-
|
M20
|
IP67 - Dust Tight, Waterproof
|
CCC, CE, TUV, UL
|
|
|
|
HS5L
|
Active
|
Bulk
|
Solenoid Release
|
DPST-NO/NC x 2
|
2.5A (AC/DC)
|
125VAC, 30VDC
|
24VDC
|
143kgf
|
Panel Disconnect
|
Spring Terminal
|
-
|
-
|
-
|
M20
|
IP67 - Dust Tight, Waterproof
|
CCC, CE, TUV, UL
|
|
|
|
HS5L
|
Active
|
Bulk
|
Solenoid Release
|
DPST-NO/NC x 2
|
2.5A (AC/DC)
|
125VAC, 30VDC
|
24VDC
|
143kgf
|
Panel Disconnect
|
Spring Terminal
|
-
|
-
|
-
|
M20
|
IP67 - Dust Tight, Waterproof
|
CCC, CE, TUV, UL
|
|
|
|
HS5L
|
Active
|
Bulk
|
Solenoid Release
|
DPST-NC x 2
|
2.5A (AC/DC)
|
125VAC, 30VDC
|
24VDC
|
143kgf
|
Panel Disconnect
|
Spring Terminal
|
-
|
-
|
-
|
M20
|
IP67 - Dust Tight, Waterproof
|
CCC, CE, TUV, UL
|
|
|
|
HS5L
|
Active
|
Bulk
|
Solenoid Release
|
DPST-NC x 2
|
2.5A (AC/DC)
|
125VAC, 30VDC
|
24VDC
|
143kgf
|
Panel Disconnect
|
Spring Terminal
|
-
|
-
|
-
|
M20
|
IP67 - Dust Tight, Waterproof
|
CCC, CE, TUV, UL
|
|
|
|
HS5E
|
Obsolete
|
Bulk
|
Solenoid Locking
|
3PST-NC + SPST-NC
|
2.5A (AC/DC)
|
125VAC, 30VDC
|
24VDC
|
143kgf
|
Panel Disconnect
|
Cable Leads
|
Status Indicator
|
-
|
-
|
-
|
IP67 - Dust Tight, Waterproof
|
CCC, CE, cURus, TUV
|
|
|
|
HS5E
|
Obsolete
|
Bulk
|
Solenoid Locking
|
3PST-NC + SPST-NC
|
2.5A (AC/DC)
|
125VAC, 30VDC
|
24VDC
|
143kgf
|
Panel Disconnect
|
Cable Leads
|
Status Indicator
|
-
|
-
|
-
|
IP67 - Dust Tight, Waterproof
|
CCC, CE, cURus, TUV
|
|
|
|
HS5E
|
Obsolete
|
Bulk
|
Solenoid Release
|
3PST-NC + SPST-NC
|
2.5A (AC/DC)
|
125VAC, 30VDC
|
24VDC
|
143kgf
|
Panel Disconnect
|
Cable Leads
|
Status Indicator
|
-
|
-
|
-
|
IP67 - Dust Tight, Waterproof
|
CCC, CE, cURus, TUV
|
|
|
|
HS5E
|
Obsolete
|
Bulk
|
Solenoid Release
|
3PST-NC + SPST-NC
|
2.5A (AC/DC)
|
125VAC, 30VDC
|
24VDC
|
143kgf
|
Panel Disconnect
|
Cable Leads
|
Status Indicator
|
-
|
-
|
-
|
IP67 - Dust Tight, Waterproof
|
CCC, CE, cURus, TUV
|
|
|
|
HS5E
|
Obsolete
|
Bulk
|
Solenoid Locking
|
DPST-NC x 2
|
2.5A (AC/DC)
|
125VAC, 30VDC
|
24VDC
|
143kgf
|
Panel Disconnect
|
Cable Leads
|
Status Indicator
|
-
|
-
|
-
|
IP67 - Dust Tight, Waterproof
|
CCC, CE, cURus, TUV
|
|
|
|
HS5E
|
Obsolete
|
Bulk
|
Solenoid Locking
|
DPST-NC x 2
|
2.5A (AC/DC)
|
125VAC, 30VDC
|
24VDC
|
143kgf
|
Panel Disconnect
|
Cable Leads
|
-
|
-
|
-
|
-
|
IP67 - Dust Tight, Waterproof
|
CCC, CE, cURus, TUV
|
|
|
|
HS5E
|
Obsolete
|
Bulk
|
Solenoid Locking
|
DPST-NC x 2
|
2.5A (AC/DC)
|
125VAC, 30VDC
|
24VDC
|
143kgf
|
Panel Disconnect
|
Cable Leads
|
Status Indicator
|
-
|
-
|
-
|
IP67 - Dust Tight, Waterproof
|
CCC, CE, cURus, TUV
|
|
|
|
HS5E
|
Obsolete
|
Bulk
|
Solenoid Locking
|
DPST-NC x 2
|
2.5A (AC/DC)
|
125VAC, 30VDC
|
24VDC
|
143kgf
|
Panel Disconnect
|
Cable Leads
|
Status Indicator
|
-
|
-
|
-
|
IP67 - Dust Tight, Waterproof
|
CCC, CE, cURus, TUV
|
|
|
|
HS5E
|
Obsolete
|
Bulk
|
Solenoid Release
|
DPST-NC x 2
|
2.5A (AC/DC)
|
125VAC, 30VDC
|
24VDC
|
143kgf
|
Panel Disconnect
|
Cable Leads
|
Status Indicator
|
-
|
-
|
-
|
IP67 - Dust Tight, Waterproof
|
CCC, CE, cURus, TUV
|
|
|
|
HS5E
|
Obsolete
|
Bulk
|
Solenoid Release
|
DPST-NC x 2
|
2.5A (AC/DC)
|
125VAC, 30VDC
|
24VDC
|
143kgf
|
Panel Disconnect
|
Cable Leads
|
Status Indicator
|
-
|
-
|
-
|
IP67 - Dust Tight, Waterproof
|
CCC, CE, cURus, TUV
|
|
|
|
HS5E
|
Obsolete
|
Bulk
|
Solenoid Release
|
DPST-NC x 2
|
2.5A (AC/DC)
|
125VAC, 30VDC
|
24VDC
|
143kgf
|
Panel Disconnect
|
Cable Leads
|
Status Indicator
|
-
|
-
|
-
|
IP67 - Dust Tight, Waterproof
|
CCC, CE, cURus, TUV
|
|
|
|
HS5E
|
Obsolete
|
Bulk
|
Solenoid Release
|
DPST-NC x 2
|
2.5A (AC/DC)
|
125VAC, 30VDC
|
24VDC
|
143kgf
|
Panel Disconnect
|
Cable Leads
|
Status Indicator
|
-
|
-
|
-
|
IP67 - Dust Tight, Waterproof
|
CCC, CE, cURus, TUV
|
|
|
|
HS5E
|
Obsolete
|
Bulk
|
Solenoid Locking
|
DPST-NO/NC + DPST-NC
|
2.5A (AC/DC)
|
125VAC, 30VDC
|
24VDC
|
143kgf
|
Panel Disconnect
|
Cable Leads
|
Status Indicator
|
-
|
-
|
-
|
IP67 - Dust Tight, Waterproof
|
CCC, CE, cURus, TUV
|
|
|
|
HS5E
|
Obsolete
|
Bulk
|
Solenoid Locking
|
DPST-NO/NC + DPST-NC
|
2.5A (AC/DC)
|
125VAC, 30VDC
|
24VDC
|
143kgf
|
Panel Disconnect
|
Cable Leads
|
Status Indicator
|
-
|
-
|
-
|
IP67 - Dust Tight, Waterproof
|
CCC, CE, cURus, TUV
|
|
|
|
HS5E
|
Obsolete
|
Bulk
|
Solenoid Locking
|
DPST-NO/NC + DPST-NC
|
2.5A (AC/DC)
|
125VAC, 30VDC
|
24VDC
|
143kgf
|
Panel Disconnect
|
Cable Leads
|
Status Indicator
|
-
|
-
|
-
|
IP67 - Dust Tight, Waterproof
|
CCC, CE, cURus, TUV
|
|
|
|
HS5E
|
Obsolete
|
Bulk
|
Solenoid Release
|
DPST-NO/NC + DPST-NC
|
2.5A (AC/DC)
|
125VAC, 30VDC
|
24VDC
|
143kgf
|
Panel Disconnect
|
Cable Leads
|
Status Indicator
|
-
|
-
|
-
|
IP67 - Dust Tight, Waterproof
|
CCC, CE, cURus, TUV
|
|
|
|
HS5E
|
Obsolete
|
Bulk
|
Solenoid Release
|
DPST-NO/NC + DPST-NC
|
2.5A (AC/DC)
|
125VAC, 30VDC
|
24VDC
|
143kgf
|
Panel Disconnect
|
Cable Leads
|
Status Indicator
|
-
|
-
|
-
|
IP67 - Dust Tight, Waterproof
|
CCC, CE, cURus, TUV
|